ITB2026-108 Tybee Island Marine Science Center Restrooms

Agency: City of Tybee Island
State: Georgia
Type of Government: State & Local
NAICS Category:
  • 541690 - Other Scientific and Technical Consulting Services
  • 541990 - All Other Professional, Scientific, and Technical Services
Posted Date: Apr 16, 2026
Due Date: May 19, 2026
Solicitation No: ITB2026-108
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Bid Number: ITB2026-108
Bid Title: ITB2026-108 Tybee Island Marine Science Center Restrooms
Category: Open RFPs
Status: Open
Description:

The City of Tybee Island, GA will be accepting bids for the Marine Science Center Restrooms. BIDS MUST BE SUBMITTED BY 2:00 PM ON TUESDAY, MAY 19, 2026, to Aleesha Robinson, at Tybee Island City Hall, 403 Butler Avenue, Tybee Island, GA 31328. A PRE-BID MEETING will be held 1:00PM, THURSDAY, APRIL 30, 2026, at the Public Safety Building Conference Room (78 Van Horne) all prospective bidders are strongly encouraged to attend. Direct all questions in writing to Aleesha Robinson at For security reasons, you must enable JavaScript to view this E-mail address. The City of Tybee Island, GA may (i) reject any, any part of, or all bids and proposals with any party submitting a bid or proposal, or (ii) waive informalities and technicalities, (iii) negotiate directly with any party submitting a bid or proposal, or (iv) accept that proposal which the City of Tybee Island, GA deems to be in its best interest, whether or not it is the lowest dollar proposal.

Publication Date/Time:
4/16/2026 12:00 AM
Closing Date/Time:
5/19/2026 2:00 PM
Related Documents:

Attachment Preview

PROJECT MANUAL
INVITATION TO BID
ITB NO. 2026-108
CITY OF TYBEE ISLAND -
TYBEE MARINE SCIENCE - RESTROOMS
Tybee Island, GA
MARCH 2026
PREPARED BY
GREENLINE ARCHITECTURE
28 E 35TH ST
SAVANNAH, GA 31401
T 912.447.5665
F 912.447.8381

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
TABLE OF CONTENTS
SECTION No. SECTION TITLE
000000 TABLE OF CONTENTS
DIVISION 1 - GENERAL REQUIREMENTS
------- INTRODUCTION
------- SPECIFICATIONS AND REQUIREMENTS
1.INSTRUCTIONS TO BIDDERS
2.GENERAL INFORMATION
3.BID AND PERFORMANCE BOND
DIVISION 2 - SITEWORK
023610 TERMITE CONTROL
DIVISION 3 - CONCRETE
SEE STRUCTURAL
DIVISION 4 - MASONRY
042201 REINFORCED CONCRETE UNIT MASONRY/ SEE A5.1, ALSO
STRUCTURAL
DIVISION 6 - WOOD AND PLASTICS
061000 ROUGH CARPENTRY
061600 SHEATHING
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
074113 METAL ROOFING
079200 JOINT SEALANTS
Table of Contents 000000 - 1

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
DIVISION 8 - OPENINGS
087100 DOOR HARDWARE
DIVISION 9 - FINISHES
099113 PAINTING
099600 HIGH PERFORMANCE COATINGS
DIVISION 10 - MISC
SEE ATTACHED
Table of Contents 000000 - 2

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
SECTION 023610 - TERMITE CONTROL
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section includes the following for termite control:
1. Soil treatment.
1.3 DEFINITIONS
A. EPA: Environmental Protection Agency.
B. PCO: Pest control operator.
1.4 SUBMITTALS
A. Product Data: Treatments and application instructions, including EPA-Registered
Label.
B. Product Certificates: Signed by manufacturers of termite control products certifying
that treatments furnished comply with requirements.
C. Qualification Data: For firms and persons specified in "Quality Assurance" Article to
demonstrate their capabilities and experience. Include lists of completed projects with
project names and addresses, names and addresses of architects and owners, and other
information specified.
D. Soil Treatment Application Report: After application of termiticide is completed,
submit report for Owner's record information, including the following as applicable:
1. Date and time of application.
2. Moisture content of soil before application.
3. Brand name and manufacturer of termiticide.
4. Quantity of undiluted termiticide used.
5. Dilutions, methods, volumes, and rates of application used.
6. Areas of application.
TERMITE CONTROL 023610 - 1

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
7. Water source for application.
E. Warranties: Special warranties specified in this Section.
1.5 QUALITY ASSURANCE
A. Applicator Qualifications: A PCO who is licensed according to regulations of
authorities having jurisdiction to apply termite control treatment in jurisdiction where
Project is located and who is experienced and has completed termite control treatment
similar to that indicated for this Project and whose work has a record of successful in-
service performance.
B. Regulatory Requirements: Formulate and apply termiticides, and label with a Federal
registration number, to comply with EPA regulations and authorities having
jurisdiction.
1.6 PROJECT CONDITIONS
A. Environmental Limitations: To ensure penetration, do not treat soil that is water
saturated or frozen. Do not treat soil while precipitation is occurring. Comply with
EPA-Registered Label requirements and requirements of authorities having jurisdiction.
1.7 COORDINATION
A. Coordinate soil treatment application with excavating, filling, and grading and
concreting operations. Treat soil under footings, grade beams, and ground-supported
slabs, before construction.
1.8 WARRANTY
A. General Warranty: Special warranty specified in this Article shall not deprive Owner of
other rights Owner may have under other provisions of the Contract Documents and
shall be in addition to, and run concurrent with, other warranties made by Contractor
under requirements of the Contract Documents.
B. Special Warranty: Written warranty, signed by applicator and Contractor certifying that
termite control work, consisting of applied soil termiticide treatment, will prevent
infestation of subterranean termites. If subterranean termite activity or damage is
discovered during warranty period, re-treat soil and repair or replace damage caused by
termite infestation.
C. Warranty Period: Five years from date of Substantial Completion.
TERMITE CONTROL 023610 - 2

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
1.9 MAINTENANCE SERVICE
A. Continuing Service: Provide a proposal for continuing service, including monitoring,
inspection, and retreatment for occurrences of termite activity, from applicator to
Owner, in the form of a standard yearly (or other period) continuing service agreement,
starting on the date of Substantial Completion. State services, obligations, conditions,
and terms for agreement period and for future renewal options.
PART 2 - PRODUCTS
2.1 SOIL TREATMENT
A. Termiticide: Provide an EPA-registered termiticide complying with requirements of
authorities having jurisdiction, in a soluble or emulsible, concentrated formulation that
dilutes with water or foaming agent, and formulated to prevent termite infestation. Use
only soil treatment solutions that are not harmful to plants. Provide quantity required
for application at the label volume and rate for the maximum termiticide concentration
allowed for each specific use, according to the product's EPA-Registered Label.
B. Manufacturers: Subject to compliance with requirements, provide products by one of
the following:
1. AgrEvo Environmental Health, Inc.; a Company of Hoechst and Schering, Berlin.
2. American Cyanamid Co.; Agricultural Products Group; Specialty Products
Department.
3. Bayer Corp.; Garden & Professional Care.
4. DowElanco.
5. FMC Corp.; Pest Control Specialties.
6. Zeneca Professional Products.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, areas, and conditions, with Applicator present, for compliance with
requirements for moisture content of the soil, interfaces with earthwork, slab and
foundation work, landscaping, and other conditions affecting performance of termite
control. Proceed with application only after unsatisfactory conditions have been
corrected.
TERMITE CONTROL 023610 - 3

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
3.2 PREPARATION
A. General: Comply with the most stringent requirements of authorities having
jurisdiction and with manufacturer's written instructions for preparing substrate.
Remove all extraneous sources of wood cellulose and other edible materials such as
wood debris, tree stumps and roots, stakes, formwork, and construction waste wood
from soil and around foundations.
B. Soil Treatment Preparation: Remove foreign matter and impermeable soil materials
that could decrease treatment effectiveness on areas to be treated. Loosen, rake, and
level soil to be treated, except previously compacted areas under slabs and footings.
Termiticides may be applied before placing compacted fill under slabs if recommended
by termiticide manufacturer.
C. Fit filling hose connected to water source at the site with a backflow preventer,
complying with requirements of authorities having jurisdiction.
3.3 APPLICATION, GENERAL
A. General: Comply with the most stringent requirements of authorities having
jurisdiction and with manufacturer's EPA-Registered Label for products.
3.4 APPLYING SOIL TREATMENT
A. Application: Mix soil treatment termiticide solution to a uniform consistency. Provide
quantity required for application at the label volume and rate for the maximum specified
concentration of termiticide, according to manufacturer's EPA-Registered Label, to the
following so that a continuous horizontal and vertical termiticidal barrier or treated zone
is established around and under building construction. Distribute the treatment evenly.
1. Slabs-on-Grade and Basement Slabs: Under ground-supported slab construction,
including footings, building slabs, and attached slabs as an overall treatment.
Treat soil materials before concrete footings and slabs are placed.
2. Foundations: Adjacent soil including soil along entire inside perimeter of
foundation walls, along both sides of interior partition walls, around plumbing
pipes and electric conduit penetrating slab, and around interior column footers,
piers, and chimney bases; and along entire outside perimeter, from grade to
bottom of footing. Avoid soil washout around footings.
3. Penetrations: At expansion joints, control joints, and areas where slabs will be
penetrated.
B. Avoid disturbance of treated soil after application. Keep off treated areas until
completely dry.
TERMITE CONTROL 023610 - 4

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
C. Protect termiticide solution, dispersed in treated soils and fills, from being diluted until
ground-supported slabs are installed. Use waterproof barrier according to EPA-
Registered Label instructions.
D. Post warning signs in areas of application.
E. Reapply soil treatment solution to areas disturbed by subsequent excavation, grading,
landscaping, or other construction activities following application.
END OF SECTION 02361
TERMITE CONTROL 023610 - 5

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
SECTION 042201 - REINFORCED CONCRETE UNIT MASONRY
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Concrete masonry units.
2. Steel reinforcing bars.
1.2 DEFINITIONS
A. CMU(s): Concrete masonry unit(s).
B. Reinforced Masonry: Masonry containing reinforcing steel in grouted cells.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: For reinforcing steel. Detail bending, lap lengths, and placement of unit
masonry reinforcing bars. Comply with ACI 315.
1.4 INFORMATIONAL SUBMITTALS
A. Material Certificates: For each type and size of product. For masonry units, include data
on material properties.
B. Mix Designs: For each type of mortar and grout. Include description of type and
proportions of ingredients.
1. Include test reports for mortar mixes required to comply with property
specification. Test according to ASTM C 109/C 109M for compressive strength,
ASTM C 1506 for water retention, and ASTM C 91/C 91M for air content.
2. Include test reports, according to ASTM C 1019, for grout mixes required to
comply with compressive strength requirement.
1.5 FIELD CONDITIONS
A. Cold-Weather Requirements: Do not use frozen materials or materials mixed or coated
with ice or frost. Do not build on frozen substrates. Remove and replace unit masonry
REINFORCED CONCRETE UNIT MASONRY 042201 - 1

City of Tybee Island - Tybee Island- Marine Science Center-Bathroom
Tybee Island, GA March 2026
damaged by frost or by freezing conditions. Comply with cold-weather construction
requirements contained in TMS 602/ACI 530.1/ASCE 6.
B. Hot-Weather Requirements: Comply with hot-weather construction requirements
contained in TMS 602/ACI 530.1/ASCE 6.
PART 2 - PRODUCTS
2.1 UNIT MASONRY, GENERAL
A. Masonry Standard: Comply with TMS 602/ACI 530.1/ASCE 6, except as modified by
requirements in the Contract Documents.
B. Defective Units: Referenced masonry unit standards may allow a certain percentage of
units to contain chips, cracks, or other defects exceeding limits stated. Do not use units
where such defects are exposed in the completed Work.
C. Fire-Resistance Ratings: Comply with requirements for fire-resistance-rated assembly
designs indicated.
2.2 CONCRETE MASONRY UNITS
A. Shapes: Provide shapes indicated and as follows, with exposed surfaces matching
exposed faces of adjacent units unless otherwise indicated.
1. Provide special shapes for lintels, corners, jambs, sashes, movement joints,
headers, bonding, and other special conditions.
B. CMUs: ASTM C 90.
1. Unit Compressive Strength: Provide units with minimum average net-area
compressive strength of 3000 psi (14.8 MPa).
2. Density Classification: Lightweight unless otherwise indicated.
C. Concrete Building Brick: ASTM C 55.
1. Unit Compressive Strength: Provide units with minimum average net-area
compressive strength of 3000 psi (19.3 MPa).
2. Density Classification: Lightweight.
REINFORCED CONCRETE UNIT MASONRY 042201 - 2

This page summarizes the opportunity, including an overview and a preview of the attached documents.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

DATE: July 16, 2026 Request For Proposal--July 16, 2026 - Investment Management and

Troup County

Bid Due: 8/20/2026

Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-92800-RFQC-2027-000000015

State Government of Georgia

Bid Due: 8/10/2026

Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-67500-NONST-2027-000000163

State Government of Georgia

Bid Due: 8/12/2026

Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-67550-NONST-2026-000000010

State Government of Georgia

Bid Due: 8/05/2026