Inspect, Diagnose, Repair 7890B Gas Chromatograph w/ Flame Ionization Detector
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | Washington |
| Type of Government: | Federal |
| FSC Category: |
|
| Posted Date: | Mar 19, 2025 |
| Due Date: | Mar 24, 2025 |
| Solicitation No: | N4523A25Q6007 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- Original Published Date: Mar 19, 2025 04:11 pm PDT
- Original Date Offers Due: Mar 24, 2025 12:00 pm PDT
- Inactive Policy: 15 days after date offers due
- Original Inactive Date: Apr 08, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: J066 - MAINT/REPAIR/REBUILD OF EQUIPMENT- INSTRUMENTS AND LABORATORY EQUIPMENT
-
NAICS Code:
- 811210 - Electronic and Precision Equipment Repair and Maintenance
-
Place of Performance:
Bremerton , WA 98314USA
This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with the format in subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued.
DESCRIPTION:
Inspect and repair services for 7890B Gas Chromatograph (GC) with Flame Ionization Detector (FID) to bring equipment to a functional state.
Functional state is defined by the following:
• FID flame is able to light.
• FID signal reads 0 Hz when the detector’s electrometer is turned off.
• FID signal increases when the detector’s electrometer is turned on.
• FID signal changes in response to changes in the flow of gases applied to the FID (real-time responsiveness to applied stimuli)
The below parts will be installed into the GC/FID if the currently installed part is determined to be defective.
7890B GC/FID parts:
- FID interface board
- FID electrometer PCA
- FID interconnect assembly
- FID collector assembly
The Vendor is to provide a quote (Including parts and labor) for any additional recommended repairs.
- 1400 FARRAGUT AVE
- BREMERTON , WA 98314-5001
- USA
- Crystal McCarthy
- crystal.m.mccarthy2.civ@us.navy.mil
- Jackie Edgerton
- jacqueline.f.edgerton.civ@us.navy.mil
- Mar 19, 2025 04:11 pm PDTCombined Synopsis/Solicitation (Original)
See Also
Follow CALIBRATION AND MAINTENANCE SERVICE BALANCES AND WEIGHING DEVICES Active Contract Opportunity Notice
DEPT OF DEFENSE
Due by 9/15/2026
Follow HVAC Replacement -Mount Baker-Snoqualmie National Forest Active Contract Opportunity Notice ID 1240BJ26Q0052
AGRICULTURE, DEPARTMENT OF
Due by 9/15/2026
SEP Program: Solicitation Name: MBE Bus Fire Suppression System Maintenance SEP %: Solicitation
Washington Metropolitan Area Transit Authority
Due by 10/07/2026
Follow CGC HEALY SPIRAX SARCO STEAM TRAP Active Contract Opportunity Notice ID 70Z08526Q0027750
HOMELAND SECURITY, DEPARTMENT OF
Due by 9/16/2026