Inner Loop Annex Dehumidification Solicitation
| Agency: | State Government of Texas |
|---|---|
| State: | Texas |
| Type of Government: | State & Local |
| Posted Date: | Aug 18, 2026 |
| Due Date: | Sep 17, 2026 |
| Solicitation No: | 26RFCSP61 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
26RFCSP61
Posted
Michelle McKinney
(512) 943-3878
michelle.mckinney@wilcotx.gov
9/17/2026
3:00 PM
C2460
21+ Days for Solicitation Notice
Exempt (Attorney or Texas SmartBuy Member)
8/18/2026
8/18/2026 8:54 am
03100-Air Conditioning, Heating, And Ventilating Equipment, Parts And Accessories (See Class 740 Also);
91200-Construction Services, General (Incl. Maintenance And Repair Services);
03103-Air Conditioners Systems, Commercial and Industrial, Including Parts and Accessories, (Not Otherwise Classified);
District 1,
District 2,
District 3,
District 4,
District 5,
District 6,
District 7,
District 8,
District 9,
District 10,
District 11,
District 12,
District 13,
District 14,
District 15,
District 16,
District 17,
District 18,
District 19,
District 20,
District 21,
District 22,
District 23,
District 24,
District 25
Pursuant to Chapter 2269 Subchapter D of the Texas Government Code, Williamson County (County) is seeking written proposals from qualified contractors to provide Competitive Sealed Proposals for Inner Loop Annex (ILA) Dehumidification Project. County intends to utilize the one-step selection process for this solicitation and award.This project shall consist of upgrades to the HVAC system at Williamson County’s Inner Loop Annex (ILA). The project includes the replacement of five (5) existing packaged rooftop units and one (1) 100% outside air unit with similar equipment having DX cooling, natural gas heating, and hot gas reheat for dehumidification. Replacement equipment shall be tied into the existing building automation system by Automated Logic. Minor ductwork modifications shall be made to account for the increased minimum outside air requirements presented in today’s codes. Both power and natural gas shall be disconnected from the existing-to-be-demolished equipment and reconnected to the replacement equipment. Structural work will include modification of existing roof openings to suit the replacement RTU sizes and ducts as needed. New structural steel framing shall be added to support the new mechanical equipment as needed.
See Also
Plumbing Parts for Clemens Unit Follow Solicitation Solicitation ID: IW270678 Status: Posted Contact
State Government of Texas
Due by 11/16/2026
IFB 2027-B03 Countywide Dumpsters Follow Solicitation Solicitation ID: IFB2027-B03 Status: Posted Contact Name:
State Government of Texas
Due by 11/20/2026
Plumbing Parts for Scott Unit Follow Solicitation Solicitation ID: IW265291 Status: Posted Contact
State Government of Texas
Due by 11/06/2026
Project: Remove & Replace Duct Heater Ref. #: 2098340 Type: RFQ Status: Open
Dallas Area Rapid Transit
Due by 11/06/2026