Harmony High School Baseball and Softball Sports Lighting Replacement Project

Agency: Osceola County School Board
State: Florida
Type of Government: State & Local
NAICS Category:
  • 236220 - Commercial and Institutional Building Construction
  • 238210 - Electrical Contractors and Other Wiring Installation Contractors
Posted Date: Mar 3, 2026
Due Date: Apr 7, 2026
Solicitation No: SDOC-26-B-074-ML
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Main

Agency
Osceola County School Board
Status
Active
Fiscal Year
2026
Primary Contact
Melanie Lachmiller
Title
Harmony High School Baseball and Softball Sports Lighting Replacement Project
Secondary Contact
Cheryl Hood
Number
SDOC-26-B-074-ML
Tertiary Contact

Type
Invitation to Bid
Department
Maintenance
Online Submissions
Yes
Project Estimate
Piggyback Solicitation
No
Insurance Required
Yes
Bid Bond Required
No
Bid Bond Amount

Performance Bond Required
Yes
Performance Bond Amount

Construction Bond Required
No
Construction Bond Amount

Scope of Services
This Specification establishes the minimum requirements for this solicitation, listed and described in the body of these specifications, to be used as noted, by The School Board of Osceola County, FL.

The intent of this bid is to secure firm fixed pricing for the lighting system performance and design standards for the Baseball and Softball Fields at Harmony High School, using an LED Lighting source. The contractor shall supply lighting equipment to meet or exceed the standards set forth in these specifications.

A.        Field to be lit:

1.        Softball– 200’

2.        Baseball – 315’/350’/315’

B.        The primary goals of this sports lighting project are:

1.        Guaranteed Light Levels for each field. Light levels are guaranteed to not drop below specified target values for a period of 10 years.

2.        Environmental Light Control: It is the primary goal of Osceola County School District to reduce spill light to adjoining properties as well as reduce glare to the players, spectators and neighbors. The LED design should incorporate glare control. The LED design should provide equal to or better glare control than what is currently installed.

3.        The preferred lighting system shall be energy-efficient and cost effective to operate. Fixture Types to be comparable to Mucso’s TLC-LED-1500, TLC-LED-1200, TLC-LED-550, TLC-LED-900 or equivalent.

4.        Contractor shall be responsible for securing necessary permits.

2.01        LIGHTING PERFORMANCE

A.        Venues to be lit to an average target illumination level and uniformity as specified in the chart below. Lighting calculations shall be developed, and field measurements taken on the grid spacing with the minimum number of grid points specified below. Appropriate light loss factors shall be applied and submitted for the basis of design. Average illumination level shall be measured in accordance with the IESNA LM-5-04 (IESNA Guide for Photometric Measurements of Area and Sports Lighting Installations). Illumination levels shall not drop below desired target values in accordance to IES RP-6-15, Page 2, Maintained Average Illuminance and shall be guaranteed for the full warranty period.

Area of Lighting        Average Target Illumination Levels        Maximum to Minimum Uniformity Ratio        Grid Points        Grid Spacing

Softball Infield        50fc        2.0:1        25        20` x 20`

Softball Outfield        30fc        2.5:1        152        20` x 20`

Baseball Infield        50fc        2.0:1        25        30` x 30`

Baseball Outfield        30fc        2.5:1        70        30` x 30`
B.        LED Color: The lighting system shall have a minimum color temperature of 5700K and a CRI of 75+.
C.        Mounting Heights: Existing poles

Field        Pole Designation        Number of Poles        Pole Height

Softball        All Poles        5        60’

Baseball        All Poles        6        70’
2.02        ENVIRONMENTAL LIGHT CONTROL

A.         All luminaires shall utilize spill light and glare control devices including, but not limited to, internal shields, louvers and external shields.

B.        The desire of The Osceola School District is to reduce spill and glare to the community and the players. The criteria below must be submitted with your bid for the design engineer to make that determination

C.        The first page of a photometric report for all luminaire types proposed showing horizontal and vertical axial candle power shall be provided to demonstrate the capability of achieving the specified performance. Reports shall be certified by a qualified independent testing laboratory with a minimum of five years` experience or by a manufacturer’s laboratory with a current accreditation under the National Voluntary Laboratory Accreditation Program for Energy Efficient Lighting Products. A summary of the horizontal and vertical aiming angles for each luminaire shall be included with the photometric report.

D.        In accordance with IES RP 6-20, manufacturers must submit candela glare readings at 150’ from the fields edges in all directions.

E.        The Fixtures proposed shall be the same or better at controlling glare to the community. Therefore, the candela shall not exceed the candlepower at the specified degrees above the center of the beam in the vertical plane as specified in the following table. Information must be verified by the photometric report required.
NEMA Classification of

Vertical Beam        Candela        Degrees Above the Center of the Beam in the Vertical Plane

4        10,348        19.5 degrees
2.03        LIGHTING FOR AERIAL SPORTS

A.        For fixtures that provide less than 10,000 candelas above 22 degrees vertical, the owner requires luminaires mounted approximately 15’ above grade to provide targeted light above the playing field. These fixtures will not emit direct light less than 10° above the horizon, and no more than 10% of the total (directly) applied lumens as modeled may be in this area.

2.04        REMOVAL OF EXISTING FIXTURES

A.        Disconnect and remove existing light fixtures from the baseball field poles.

B.        Disconnect and remove existing light fixtures from the softball field poles.

C.        Properly dispose of removed fixtures in accordance with local regulations.
2.05        INSTALLATION OF NEW LED FIXTURES

A.        Install new Musco model TLC-BT-575 LED drivers or equal at the lower portion of each pole in the existing box for ease of access and maintenance.

B.        All wiring shall be enclosed within the cross-arms, pole, or electrical components enclosure. No external wiring or SO Cords are allowed

C. Replacing the existing crossarms with Galvanized steel tubular cross-arm assembly. Angle Iron crossarms are not allowed

D.        Contractors will remote all drivers and supporting electrical equipment in aluminum enclosures mounted approximately 10 feet above grade. The enclosures shall be touch-safe and include drivers and fusing with indicator lights on fuses to notify when a fuse is to be replaced for each luminaire. Disconnect per circuit for each pole structure will be located in the enclosure. Integral driver fixtures will not be accepted. Active cooling technologies will not be considered.
E.        Contractors shall provide surge protection at the pole equal to or greater than 40kA for each line to ground (Common Mode) as recommended by IEEE C62.41.2_2002.
F.        Wire harnesses from the top of the pole to the remote driver are required, complete with an abrasion protection sleeve, strain relief and plug-in connections for fast, trouble-free installation.
G.        All luminaires, visors, and cross-arm assemblies shall withstand 150 mph winds and maintain luminaire aiming alignment.
H.        Contractor shall verify the grounding of each pole. Ohm reading must be taken, and reading must be below published standards.

I.        All system components shall be UL listed for the appropriate application.

J.        Ensure grounding components meet minimum standards required by NEC and NFPA780.

K.        New lightning down conductor(aluminum) and 5/8” copper ground rod on poles 75’ or less use 1/0 AWG, poles.

L.        Ensure all components are bonded to both equipment and lightning grounds. No upward sweeps allowed for lightning down conductor or bonding jumper(s).
M.        Test ground resistance with 3-point megger and confirm 25 ohms or less for each pole. Install additional ground rods or create grounding grid until resistance of 25 ohms or less is achieved.

N.        Lights shall be turned on/off primarily by the use of contactors.

O.        System shall provide for instant on/off of luminaires.
2.06        FIELD QUALITY CONTROL

A.        Field Light Level Accountability

1.        Light levels are guaranteed not to fall below the target maintained light levels for the entire warranty period of 10 Years.

2.        The contractor/manufacturer will be held responsible for any and all changes needed to bring these fields back to compliance for light levels and uniformities. Contractor/Manufacturer will be held responsible for any damage to the fields during these repairs.

2.07        WARRANTY AND GUARANTEE FOR PRODUCT

A.        10-Year Warranty: Each manufacturer shall supply a signed warranty covering the entire system for 10 years from the date of Installation. Warranty shall guarantee specified light levels. Warranty does not cover weather conditions, events such as lightning or hail damage, improper installation, vandalism or abuse, unauthorized repairs or alterations, or products made by other manufacturers.

2.08        RESPONDENT’S QUALIFICATIONS

A.        Certified Electrical Contractor’s License for Electrical Work, issued by the State of Florida Construction Industry Licensing Board according to Florida State Statutes, Chapter 489.

2.09        RESPONDENTS REQUIREMENTS

A.        The Contractor shall furnish all labor, tools, equipment, transportation, utilities and materials to provide a total turnkey project at Harmony High School as required by the School Board’s Project Manager.
B.        The Contractor shall supervise and direct the Work, using the Contractor’s best skill and attention. The Contractor shall be solely responsible for all means, methods, techniques, sequences and procedures for coordinating all portions of the Work as a result of this ITB.


Dates(All times are listed as EST )

Broadcast Date
3/3/2026 4:00 PM EST
Question End Date
3/24/2026 12:00 PM EST
Due Date
4/7/2026 2:00 PM EST
Bid Opening Date

Pre-Bid Conferences

Total: 0 (All times are listed as EST )
Date Time Mandatory Location
Documents

Total: 13
Type Name Description File Type
Invitation to Bid ITB Template Scope of Work and Special Term & Conditions.pdf SDOC-26-B-074-ML Harmony High School Baseball and Softball Sports Lighting Replacement Project ITB PDF
Attachment Attachment A - General Terms & Conditions.pdf Attachment A - General Terms & Conditions PDF
Attachment Attachment B - ITB Respondents Acknowledgement and Required Forms.pdf Attachment B - ITB Respondents Acknowledgement and Required Forms PDF
Attachment Attachment C - References Form.pdf Attachment C - References Form PDF
Attachment Attachment D-Price Sheet.pdf Attachment D-Price Sheet PDF
Attachment Attachment E - SBE VBE Program Participation Form.pdf Attachment E - SBE VBE Program Participation Form PDF
Attachment Attachment F - Unsatisfactory Report Example.pdf Attachment F - Unsatisfactory Report Example PDF
Attachment Attachment G - Federal Terms and Conditions.pdf Attachment G - Federal Terms and Conditions PDF
Attachment Attachment H - Bidders Statement of Principal Place of Business.pdf Attachment H - Bidders Statement of Principal Place of Business PDF
Attachment Attachment I-Contract Draft Construction Agreement.pdf Attachment I-Contract Draft, Construction Agreement PDF
Attachment Attachment J-Payment Bond.pdf Attachment J-Payment Bond PDF
Attachment Attachment K-Performance Bond.pdf Attachment K-Performance Bond PDF
Attachment Attachment L- Architectural Drawings.pdf Attachment L- Architectural Drawings PDF
Quote/Bid


Zones
Total: 0
Zone

Groups
Total: 0
Group
Quote/Bid Items

Total: 0
# Required Group Make Model Description Quantity Unit of Measure Price/ Percent Type

Additional Quote/Bid Items Fields
Display Options Spreadsheet Section
No Display Image and Specifications Hyperlink Fields
No
Display Build Sheet File Upload Field
No Display Options File Upload Field
No
Require Build Sheet File to be Uploaded
No Require Options File to be Uploaded
No
Display Lead Time Field
No Display Standard Packaging Field
No
Delivery Date
None
Required Files to be Uploaded by the Vendor
Respondent`s Acknowledgement
Qualifications
Price Sheet
Bid

Shipping
None
Terms and Conditions
None
Include Shipping in Price of Items
No
Display Bid Tabulation to Vendors
No
Display Vendor Submissions to Vendors
No
View Vendor Submissions while Bid Solicitation is Active
No
Allow Options File to be Updated after Due Date
No
Allow Post Due Date Submission
No
Questions & Answers

Total: 0
Question Date Asked Answer Date Answered
Commodity Codes

Total: 68
Code Description
[285-54] Lighting Fixtures, Indoor: All Kinds and Parts (Including Lampholders and Recycled Types)
[285-55] Lighting, Area, Pole or Standard Mounted (Parking Lots, etc.)
[285-56] Lighting Fixtures, Outdoor: Floodlights, Spotlights, Yard Lights, and all other Weatherproof Fixtures (Except Streetlights) (Including Recycled Types)
[285-57] Lighting, Solar Powered
[285-58] Lighting Units, Emergency, Battery Operated; and Batteries
[855-44] Lighting and Dimming Controls: Autotransformer Dimmers, Control Panels, Solid State Thyristor/Triac Dimmers, etc.
[855-46] Lighting Control Systems: Memory and Computer/Microprocessor Type
[855-48] Lighting Distribution Hardware: Borderlight Cables, Pipe Battens, Plugging Strips and Boxes, Wall and Floor Pockets, etc.
[855-50] Lighting Instruments: Border and Cyclorama Striplights, Follow Spotlights, Floodlights, Special Effects Lighting, Spotlights, etc.
[855-53] Lighting Systems, Complete
[906-58] Lighting (Interior, Exterior) - Architectural Services
[931-53] Lighting Fixtures Maintenance and Repair
[988-54] Lighting Services for Parks, Athletic Fields, Parking Lots, etc.
[220-14] Energy Computerized Control Systems for HVAC, Lighting, Utilities, etc. Combination
[285-27] Control Devices, Lighting (Including Photocells, Multiple Relays, Lighting Contactors)
[285-76] Street and Highway Lighting Luminaires, Accessories and Parts
[557-25] Electrical Accessories and Parts (Not Lighting)
[557-50] Lamps/Lighting, Lens, and Signals, Interior and Exterior
[559-40] Electrical Accessories and Parts (Not Lighting)
[559-55] Lamps/Lighting, Interior and Exterior
[805-73] Stadium Lighting Equipment and Light Poles (See Class 285 for Lamps)
[840-72] Video Lighting Units (Portable) and Battery Packs, Accessories, etc.
[906-6] Airports (Lighting, Fueling, Navaids) - Architectural Services
[910-17] Energy Computerized Control System (HVAC, Lighting, Utilities, etc) Installation, Maintenance and Repair Services
[912-32] Construction, Street Lighting
[912-60] Maintenance and Repair, Street Lighting
[925-8] Airports (Lighting, Fueling, Navaids) - Engineering
[936-25] Electrical Equipment (Except Cable and Wires, and Lighting Fixtures) Maintenance and Repair
[060-36] Electrical Accessories: Alternators, Ammeters, Distributors, Generators, Regulators, Starters, etc.
[060-37] Electrical Parts (Not Ignition) (Not Otherwise Classified)
[120-36] Electrical Accessories and Parts, Marine
[465-29] Electrical Safety Analyzers (For Current Leakage Detection)
[557-25] Electrical Accessories and Parts (Not Lighting)
[559-40] Electrical Accessories and Parts (Not Lighting)
[760-27] Electrical Accessories, Heavy Equipment: Alternators, Ammeters, Coils, Distributors Generators, Ignition, Regulators, Starters, etc.
[914-38] Electrical
[925-31] Electrical Engineering (Incl. Cogeneration Design Services)
[928-38] Electrical (Alternator/Generator, Battery, Ignition System, Lights, etc.) Maintenance and Repair
[936-25] Electrical Equipment (Except Cable and Wires, and Lighting Fixtures) Maintenance and Repair
[967-37] Electrical and Electronic Products (Incl. Computers and Peripherals)
[981-30] Electrical Equipment and Supply Rental or Lease
[992-39] Electrical Systems Testing Services
[998-37] Electrical Equipment and Supplies, Sale of Surplus and Obsolete Items
[075-2] Alarm Systems, Visual and Audio (For Electrically and Mechanically Operated Doors)
[175-49] Interval Timers and Actuators, Electrical and Mechanical
[285-15] Coatings, Protective, Electrical
[285-25] Current Collection Equipment and Accessories, Electrical
[285-69] Misc. Electrical Equipment and Supplies (Not Otherwise Classified)
[285-9] Cabinets, Electrical Service Entrance
[285-95] Wiring Devices: Adapters, Caps, Connectors, Extension Cords, Fluorescent and HP Starters, Outlets, Plates and Covers, Plugs, Receptacles, Safety Cord Lock, Switches, Terminals, etc. (Incl. Recycled Electrical Products, Supplies)
[290-80] Solar Powered Electrical Systems (For Battery Charging, etc.)
[290-95] Wind Electrical Generating Systems and Accessories
[425-42] Filing Systems, Mobile, High Density (Electrical and Mechanical)
[450-25] Cords, Power, Electrical
[785-92] Training Aids, Materials, and Equipment for the Industrial Trades (Welding, Electrical, Instrumentation, Industrial Mechanics, etc.)
[832-26] Tape, Electrical
[832-36] Tape, Insulating, All Types (Except Electrical)
[832-40] Tape, Insulating, Electrical
[910-82] Wiring and Other Electrical Maintenance and Repair Services
[936-40] Hand Tools, Powered, All Kinds, Maintenance and Repair (Including Electrical and Hydraulic)
[936-77] Substation/High Voltage (Electrical) Maintenance and Repair
[961-65] Scanning and Testing for Electrical Hot-Spots, etc.
[968-48] Inspection Services, Electrical Instrumentation and Control
[992-40] Electronic and Electrical Cable Testing Services
[285-54] Lighting Fixtures, Indoor: All Kinds and Parts (Including Lampholders and Recycled Types)
[285-56] Lighting Fixtures, Outdoor: Floodlights, Spotlights, Yard Lights, and all other Weatherproof Fixtures (Except Streetlights) (Including Recycled Types)
[285-86] Transformers, Power Distribution (Including Fluid Filled, Pad and Pole Mount)
[285-95] Wiring Devices: Adapters, Caps, Connectors, Extension Cords, Fluorescent and HP Starters, Outlets, Plates and Covers, Plugs, Receptacles, Safety Cord Lock, Switches, Terminals, etc. (Incl. Recycled Electrical Products, Supplies)
Publications

Total: 0
Publication Date
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Description: Caloosa Park - Parking Lot Light Replacement (RE-BID) Department: Facilities Dev &

Palm Beach County

Bid Due: 4/22/2029

Description: Caloosa Park - Parking Lot Light Replacement (RE-BID) Department: Facilities Dev &

Palm Beach County

Bid Due: 5/01/2030

New Smyrna Beach High - Baseball and Softball Field Lighting - Project No.

Volusia County Schools

Bid Due: 6/16/2026

New Smyrna Beach High - Baseball and Softball Field Lighting - Project No.

Volusia County Schools

Bid Due: 6/16/2026