H946--Sterile Processing Water Quality Chillicothe VA Medical Center

Agency: VETERANS AFFAIRS, DEPARTMENT OF
State: Ohio
Type of Government: Federal
FSC Category:
  • H - Quality Control, Testing, and Inspection Services
NAICS Category:
  • 221310 - Water Supply and Irrigation Systems
Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Posted Date: Aug 27, 2026
Due Date: Sep 3, 2026
Solicitation No: 36C25026Q0430
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

Follow
H946--Sterile Processing Water Quality Chillicothe VA Medical Center
Active
Contract Opportunity
Notice ID
36C25026Q0430
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Aug 27, 2026 02:10 pm EDT
  • Original Response Date: Sep 03, 2026 01:00 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Dec 11, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: H946 - OTHER QC/TEST/INSPECT- WATER PURIFICATION AND SEWAGE TREATMENT EQUIPMENT
  • NAICS Code:
    • 221310 - Water Supply and Irrigation Systems
  • Place of Performance:
    Chillicothe, , OH 45601
    USA
Description
Delivery Schedule:
The coordinating service for this initiative is CVAMC Engineering CORS. All services will be approved, coordinated, and scheduled with the Engineering COR at contract award.

All items will be delivered, and first maintenance scheduled within 30 days of contract award. Monthly service visits to be scheduled within the first week of each month. Quarterly PM service visits to be scheduled within the first week of each quarter. Service reports and water quality analysis reports should be delivered via email to the VAMC Engineering COR within five (5) business days of visit, or in the case of longer-duration tests, within three (3) days of receiving results from outside lab testing.

All work must be performed during normal working shifts, 8:00 a.m. to 4:30 p.m., Monday through Friday, excluding Federal holidays, however some tasks may need to be performed outside normal working shifts and days. The vendor will schedule & coordinate all work with Engineering COR and Chief SPS.

The contractor personnel shall sign into (and out of) the facility and obtain a Vendor s ID Badge upon every visit at Engineering, Building 21. The contractor shall then check in and check out and report to the Engineering COR in Building 21 and return the Vendor s ID Badge to Engineering, Building 21.

Period of Performance: Base Year + 4 Option Years.
=========================================================================
Evaluation Factors - Chillicothe VAMC Sterile Processing Water Quality
=====================================================================================
1.Maintenance
a. Experience and materials for service
i. CPVC Piping and Fittings
ii. Polypropylene Thermal Fusion Piping and Fittings
iii. 5844C DI Tanks
iv. Prefilter 5-micron melt blown cartridge - post DI 675100
v. Final 0.2-micron absolute polyester pleated cartridge 675145
vi. Carbon block 10-micron prefilter 2.5 x 20 cartridge 675113
vii .RO Membranes 4 x 26" XLE4021
viii. UV Lamp GL39PP (UV Lamp - 1 Year Life Change Sept) - UV module part number UVA-12C (Hydronix)
b. Emergency Response Capability
i. Declaration of response within 1 business day (as based on federal calendar)
ii. Nearest Service Location
1.Locations within 100 miles will receive priority
2.Locations within 200 miles will receive preference
2.Water Quality Analysis
a. Laboratory Qualifications
i. ISO/IEC 17025
ii. Ohio Environmental Protection Agency (Not applicable to Endotoxins ANSI/AAMI ST72/USP 85)
iii. Equivalent certification to be determined by facility review.
b. Sampling Procedures
i. Submit company policy/procedures.
ii. Sampler Resume
1.Shall have a minimum of 5 years of experience.
2.Experience with biological sampling to include Heterotopic Plate Count and Endotoxin
iii. Virtual interview with sampler will be requested
c. Transportation and Storage Procedures
i. Submit company policy/procedures
ii. Maximum transit time not to exceed 8 hours to lab intake.
d. Reporting
i. Example Report Reviewed for contents and organization
1. Shall include:
a. Biological analysis results
b. Chemical analysis results
c .AAMI ST108 Thresholds
d. Identify Water* Quality Classification
i. Utility Water
ii. Critical Water
iii. AER
iv. Steam* - Steam Condensate
e. Remediation recommendations
2. An actual report is permitted, however facility identifying information shall be redacted.
3. Report shall be watermarked or stamped on all pages with Example
3. Familiarity with AAMI ST108, Bacteriological Water Quality Management, and Water Treatment Technologies
a. Specialist Resume(s)
b. Virtual interview with specialist(s) will be requested.
c. Specialist(s) may be an individual or multiple individuals.
d. Bacteriological Water Quality Management
i. Disinfection methods
1.Manual Administration
a. Liquid disinfectants
b. Dissolved oxidizing gas
c. Concentration and Contact Time Requirements
2.Automated/Energized Systems
a. Ultraviolet
b. Metered liquid disinfection systems
c. Dissolved oxidizing gas
ii. Material/Chemical Compatibility
iii. Safety Requirements
iv. Costs
1. Initial
2. Operation/Maintenance
e. Water Treatment Technology Familiarity
i. Shall include:
1. Reverse Osmosis
2. Filtration Technologies
a. To include Carbon Filtration
3. Ion Exchange Technologies
4. Water Softeners
ii. Material/Chemical Compatibility
iii. Sizing of Technology
iv. Operations and Maintenance Requirements
v. Safety Requirements
vi. Costs
1.Initial
2.Operation/Maintenance
Attachments/Links
Contact Information
Contracting Office Address
  • VISN 10 CONSOLIDATED CONTRACTING 4100 WEST 3RD STREET
  • DAYTON , OH 45428
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Aug 27, 2026 02:10 pm EDTSources Sought (Original)

Related Document

Sep 8, 2026[Combined Synopsis/Solicitation (Original)] H946--Sterile Processing Water Quality Chillicothe VA Medical Center
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Follow H946--Sterile Processing Water Quality Chillicothe VA Medical Center Active Contract Opportunity Notice

VETERANS AFFAIRS, DEPARTMENT OF

Due by 9/15/2026

Follow Smoke and Fire Damper Inspection Active Contract Opportunity Notice ID 36C25026Q0974 Related

VETERANS AFFAIRS, DEPARTMENT OF

Due by 9/18/2026

Project Name Bid Date Bid Information LUC-2-21.72 Navarre Safety Improvement (PID 118234) -

City of Oregon

Due by 2/21/2072

Number Bid Results Advertisement Date Due Date Description 4511 Aug 31, 2026 Sep

Ohio Turnpike Commission

Due by 9/15/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.