Granite Table inspection, calibration, and lapping/repair
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | Illinois |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | No Set aside used |
| Posted Date: | Aug 20, 2026 |
| Due Date: | Sep 1, 2026 |
| Solicitation No: | W519TC-26-SS-035003 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Aug 20, 2026 09:53 am CDT
- Original Response Date: Sep 01, 2026 10:00 am CDT
- Inactive Policy: Manual
- Original Inactive Date: Sep 02, 2026
-
Initiative:
- None
- Original Set Aside: No Set aside used
- Product Service Code: H266 - EQUIPMENT AND MATERIALS TESTING- INSTRUMENTS AND LABORATORY EQUIPMENT
-
NAICS Code:
- 541380 - Testing Laboratories and Services
-
Place of Performance:
Rock Island , IL 61299USA
This is a Sources Sought only.
You MUST send e-mail to the POC (heather.j.petersen.civ@army.mil) that includes the following:
1) Company Name
2) Cage Code or EUI number
3) company POC, e-mail address, and phone number
4) capability statement that outlines you have and can complete the work outlined below.
___________________
Scope of Work (SOW)
1. Purpose: The purpose of this Scope of Work (SOW) is to define a performance-based specification to calibrate granite surface tables for the Rock Island Arsenal's Joint Manufacturing and Technology Center (JMTC). The work shall be performed by an ISO 17025 accredited vendor shall include the inspection, calibration, and lapping/repair of the tabletops of any that are not within specification.
2. Invoices for services must include a breakout of all costs and must be submitted to the JMTC Representative for review and concurance after services are completed. This is to verify that the invoices are in line with the contract prices and JTR approved prices.
3. Performance Period: Contractor’s effort will begin immediately after Contract/Task Order award. This will be for a Base year and Four Option Years for a total of five years.
4. Detailed Specifications: Rock Island Arsenal's JMTC includes the list of granite tables covered by this SOW and is represented below.
- Laboratory Grade AA
- 36A R-68-1439 48 X 96
- 36A 19567-M 60 X 120
- 36F R-82-791 60 X 96
- 36F 22387-M 48 X 72
- 36F RIA30627 48 X 96
- 36S 19583-M 48 X 96
- Laboratory Grade A
- 40A 19587-M 48 X 108
- 40A 19589-M 48 X 108
- 40B R-86-1412 72 X 120
- 40C 22487-M 48 X 96
- 40C R-85-3474 72 X 120
- 40C RIA31418 72 X 120
- 40C R-86-948 96 X 144
- 40M R-59-304 48 X 96
- 40R R-85-3475 72 X 120
- 40W 23415-M 72 X 120
- 299 R-85-3565 48 X 72
- 299 P-9299 48 X 72
4.1 Per ASME B89.3.7 the ISO 17025 accredited contractor shall inspect the granite surface plates and determine both its overall and local flatness. If necessary, the contractor will lap the working surface back to within specification standards.
4.2 Calibration and any necessary lapping shall be performed on an annual basis.
4.3 After the granite surface plate has been calibrated, the contractor shall affix a calibration sticker to the granite surface plate and provide a Service Acceptance Report (SAR) to the JMTC Representative within three (3) business days of completing the calibration.
5. Working Hours: 0600-1430 hours, Monday-Friday, Government Holidays excluded, unless otherwise authorized, and agreed upon, prior to deviation of the work schedule.
6. Security: The RIA-JMTC is an Army installation subject to Department of Defense safeguards, various precautions, and plant protection measures. At all times during the execution of this SOW, the contractor will maintain adequate plant protection devices to minimize espionage, sabotage, and other malicious destruction and damage. The contractor shall comply with all security requirements of the Rock Island Arsenal.
7. Final acceptance inspection shall be performed by the JMTC Representative to verify that all requirements of this SOW (and any modifications thereto) are satisfied.
- ACC ROCK ISLAND BLDG 60 3055 RODMAN AVE
- ROCK ISLAND , IL 61299-0000
- USA
- Heather Petersen
- heather.j.petersen.civ@army.mil
- Aug 20, 2026 09:53 am CDTSources Sought (Original)
See Also
Bid Identifier Status Broadcast Date Date Due Bid Name Addendum Attachments RFP 26-38-0-2026/cs
City of Evanston
Due by 9/25/2026
Follow FY27 Chiller Maintenance - Scott AFB - B1900 Active Contract Opportunity Notice
DEPT OF DEFENSE
Due by 9/17/2026
Follow Cathodic Protection Maintenance Services Active Contract Opportunity Notice ID SM-381952 Related Notice
ENERGY, DEPARTMENT OF
Due by 9/18/2026
Follow FY27 Chiller Maintenance - Scott AFB - B1900 Active Contract Opportunity Notice
DEPT OF DEFENSE
Due by 9/17/2026