FY26 Sewer Main Relining

Agency: State Government of North Carolina
State: North Carolina
Type of Government: State & Local
NAICS Category:
  • 237110 - Water and Sewer Line and Related Structures Construction
Posted Date: Jan 20, 2026
Due Date: Feb 5, 2026
Solicitation No: 320-320-200825TW
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Solicitation Number: 320-320-200825TW
Project Title: FY26 Sewer Main Relining
Description: It is the intent of this specification to provide for the reconstruction of pipelines and conduits by the installation of a resin-impregnated flexible tube, which is tightly formed to the original conduit. The resin is cured using either hot water under hydrostatic pressure or steam pressure within the tube. The Cured-In-Place Pipe (CIPP) will be continuous and tight-fitting. The Contractor shall be licensed and bonded in North Carolina and shall use sufficient workmen and competent supervisors in the execution of this portion of the work to ensure adequate and proper installation throughout. This specification references standards from the American Society for Testing and Materials, such as ASTM F1216 (Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube), ASTM F1743 (Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)), ASTM D5813 (Cured-in-Place Thermosetting Resin Sewer Pipe), ASTM D790 (Test Methods for Flexural Properties of Un-reinforced and Reinforced Plastics and Electrical Insulating Materials), and D2990 (Tensile, Compressive, and Flexural Creep and Creep-Rupture of Plastics) which are made a part hereof by such reference and shall be the latest edition and revision thereof. In case of conflicting requirements between this specification and these referenced documents, this specification will govern.
Opening Date: 2/5/2026 2:30 PM
Posted Date: 1/21/2026
Status: Open
Department: CITY OF ROCKY MOUNT
Solicitation Number
*
320-320-200825TW
Department
CITY OF ROCKY MOUNT
Status Reason
Open
Opening Date
2026-02-05T14:30:00.0000000
Posted Date
*
2026-01-20T15:40:08.0000000Z
Commodity Code
Water and sewer utilities
Mandatory Conference/Site Visit
2026-01-21T05:00:00.0000000Z
Special Instructions
Pre-Bid Meeting at 10:00 am est
Solicitation Type
*
Select RFP IFB RFI
Owner
Ramona Gardner
Description
It is the intent of this specification to provide for the reconstruction of pipelines and conduits by the installation of a resin-impregnated flexible tube, which is tightly formed to the original conduit. The resin is cured using either hot water under hydrostatic pressure or steam pressure within the tube. The Cured-In-Place Pipe (CIPP) will be continuous and tight-fitting. The Contractor shall be licensed and bonded in North Carolina and shall use sufficient workmen and competent supervisors in the execution of this portion of the work to ensure adequate and proper installation throughout. This specification references standards from the American Society for Testing and Materials, such as ASTM F1216 (Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube), ASTM F1743 (Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)), ASTM D5813 (Cured-in-Place Thermosetting Resin Sewer Pipe), ASTM D790 (Test Methods for Flexural Properties of Un-reinforced and Reinforced Plastics and Electrical Insulating Materials), and D2990 (Tensile, Compressive, and Flexural Creep and Creep-Rupture of Plastics) which are made a part hereof by such reference and shall be the latest edition and revision thereof. In case of conflicting requirements between this specification and these referenced documents, this specification will govern.
Attachments

Attachment Preview

Water Resources
Request for Proposal #: 320-200825TW
Sewer Main Relining FY26
Date of Issue: 1/16/2026
Proposal Due Date: 2/5/2026
At 02:30 P.M. ET
Direct all inquiries concerning this RFP to:
Tracy Winfield, Purchasing Associate II
Email: tracy.winfield@rockymountnc.gov
Phone: 252-972-1229
Attendance of bidders at pre-bid meeting is required. No bids will be
accepted from any vendor not represented at the pre-bid meeting.
RFP 320-200825TW
CONTRACTOR: _______________________________
Contents
I.
SCOPE OF WORK ....................................................................................................................................... 3
II. RFP SCHEDULE ........................................................................................................................................10
III. MANDATORY PRE-BID MEETING.........................................................................................................10
IV. QUESTIONS................................................................................................................................................10
V. MINORITY BUSINESS PARTICIPATION ..............................................................................................11
VI. PROPOSAL SUBMITTAL.........................................................................................................................11
VII. REFERENCES ............................................................................................................................................11
VIII. CITY’S RIGHTS AND OPTIONS .............................................................................................................12
ATTACHMENT A: PROPOSAL/ACCEPTANCE FORM ..................................................................................13
ATTACHMENT B: ACCEPTED by the City of Rocky Mount........................................................................14
ATTACHMENT C: G E N E R A L C O N D I T I O N S..................................................................................15
ATTACHMENT D: SUPPLEMENTARY GENERAL CONDITIONS................................................................25
ATTACHMENT E: SUPPLEMENTAL VENDOR INFORMATION ..................................................................26
ATTACHMENT F: PROJECT SPECIAL PROVISIONS ..................................................................................27
ATTACHMENT G: PROJECT MAPS ..................................................................................................................46
ATTACHMENT H: MWBE FORMS ......................................................................................................................49
Standard Form of Informal Contract and General Conditions Page 2 of 49
RFP 320-200825TW
CONTRACTOR: _______________________________
CITY OF ROCKY MOUNT
STANDARD FORM OF INFORMAL CONTRACT
AND GENERAL CONDITIONS
FOR
Project ID# 320-200825TW
I. SCOPE OF WORK
GENERAL
It is the intent of this specification to provide for the reconstruction of pipelines and conduits by the installation of a
resin-impregnated flexible tube, which is tightly formed to the original conduit. The resin is cured using either hot
water under hydrostatic pressure or steam pressure within the tube. The Cured-In-Place Pipe (CIPP) will be
continuous and tight-fitting.
The Contractor shall be licensed and bonded in North Carolina and shall use sufficient workmen and competent
supervisors in the execution of this portion of the work to ensure adequate and proper installation throughout.
This specification references standards from the American Society for Testing and Materials, such as ASTM F1216
(Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube), ASTM
F1743 (Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place
Thermosetting Resin Pipe (CIPP)), ASTM D5813 (Cured-in-Place Thermosetting Resin Sewer Pipe), ASTM D790
(Test Methods for Flexural Properties of Un-reinforced and Reinforced Plastics and Electrical Insulating Materials),
and D2990 (Tensile, Compressive, and Flexural Creep and Creep-Rupture of Plastics) which are made a part hereof
by such reference and shall be the latest edition and revision thereof. In case of conflicting requirements between
this specification and these referenced documents, this specification will govern.
LOCATIONS
STREET OR ADDRESS
821 Stone Dr.
505 Forest Hill Ave.
804 Forest Hill Ave.
812 Forest Hill Ave.
820 Forest Hill Ave.
108 Collington Ct.
2608 Amherst Rd.
2616 Amherst Rd.
Park tennis court across
from 816 Forest Hill Ave.
UPSTMH
G-105-
002
G-105-
060
G-105-
007
G-105-
004
G-105-
018
G-105-
005
G-105-
059
G-105-
058
G-105-
003
DSTMH
G-105-018
G-105-007
G-105-004
G-105-003
G-105-003
G-105-004
G-105-060
G-105-59
G-105-011
SIZE
8
8
8
8
8
8
8
8
8
LENGTH
300
169
245
142
311
278
250
232
237
MATERIAL
VCP
VCP
VCP
VCP
VCP
VCP
VCP
VCP
VCP
NOTES
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
Standard Form of Informal Contract and General Conditions Page 3 of 49
RFP 320-200825TW
CONTRACTOR: _______________________________
Park tennis court across
from 816 Forest Hill Ave.
1701 Augustus Dr.
1721 Augustus Dr.
1733 Augustus Dr.
1733 Augustus Dr. and
Cloverdale Dr.
1804 Augustus Dr.
1812 Augustus Dr.
Cloverdale Dr. between
Augustus Dr. and
Farmington Rd.
Cloverdale Dr. between
Lenoir Dr. and
Farmington Rd.
TOTAL LENGTH
G-105-
011
G-113-
021
G-113-
023
F-113-
016
F-113-
023
F-113-
018
F-113-
019
F-113-
017
F-112-
026
G-105-063
G-113-023
F-113-016
F-113-017
F-113-017
F-113-017
F-113-018
F-112-034
F-112-034
8
394
8
310
8
316
8
306
8
342
8
215
8
197
8
405
8
563
5,212 ft
VCP
VCP
VCP
VCP
VCP
VCP
VCP
VCP
VCP
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
BROKEN PIPE ROOTS IN
JOINTS
PRODUCTS
Product, Manufacturer/Installer Qualification Requirements
Since sewer products are intended to have a fifty-year design life, and in order to minimize the Owner’s risk, only
proven products with substantial successful long-term track records will be approved. All trenchless rehabilitation
products and installers must be pre-approved prior to the formal opening of proposals. The bidder shall utilize its own
forces for the work included in the pipelining process.
Products and Installers seeking approval must meet all of the following criteria to be deemed Commercially
Acceptable:
a) For a Product to be considered Commercially Proven, a minimum of 25 successful wastewater collection
system projects of a similar size and scope of work shall be performed in the U.S. and documented to the
satisfaction of the Owner to assure commercial viability.
b) For an Installer to be considered as Commercially Proven, the Installer must satisfy all insurance, financial,
and bonding requirements of the Owner. In addition, the Installer must have successfully installed at least
1,000,000 feet of a cured-in-place product in wastewater collection systems utilizing the exact product
intended for use on this project. Acceptable documentation of these minimum installations must be submitted
to the Owner. Installer’s project managers must have a minimum of 5 years of CIPP installation experience
with the exact product intended for use on this project.
c) Sewer rehabilitation products submitted for approval must provide third party test results supporting the
structural performance (short-term and long-term) of the product and such data shall be satisfactory to the
Owner. No product will be approved without independent third-party testing verification.
Standard Form of Informal Contract and General Conditions Page 4 of 49
RFP 320-200825TW
CONTRACTOR: _______________________________
d) Both the rehabilitation manufacturing and installation processes shall operate under a quality management
system which is third-party certified to ISO 9000 or other recognized organization standards. Proof of
certification shall be required for approval.
e) Proposals must be labeled clearly on the outside of the proposal envelope, listing the product name and
installer being proposed. Only proposals using pre-approved products and installers will be opened and read.
Proposals submitted on products and/or from installers that have not been pre-approved will be returned
unopened.
The owner authorizes the use of proven materials that serve to enhance the pipe performance specified herein.
Proven materials have passed independent laboratory testing, not excluding long-term (10,000 hour) structural
behavior testing and have been successfully installed to repair failing host pipes in the U. S. for at least 5 years. In
addition to the aforementioned, the owner may require that the contractor demonstrate that the enhancements
proposed exceed the specifications herein, prior to the installation of the enhanced material systems. This section in
no way shall be interpreted as authorization to deviate from the minimum standard practices set forth herein.
Documentation for products and installers seeking pre-approved status must be submitted no less than two weeks
prior to proposal due date to allow time for adequate consideration. The Owner will advise of acceptance or rejection
a minimum of three days prior to the due date. All required submittals must be satisfactory to the Owner.
Materials
a) Tube - The sewn Tube shall consist of one or more layers of absorbent non-woven felt fabric and meet the
requirements of ASTM F1216, Section 5.1 or ASTM F1743, Section 5.2.1 or ASTM D 5813, Sections 5 and
6. The tube shall be constructed to withstand installation pressures, have sufficient strength to bridge missing
pipe, and stretch to fit irregular pipe sections. Tube shall be manufactured in the USA by the installer.
b) The wet-out Tube shall have a relatively uniform thickness that when compressed at installation pressures
will equal or exceed the calculated minimum design CIPP wall thickness. Tube shall be wet out by the
installer.
c) The Tube shall be manufactured to a size that when installed will tightly fit the internal circumference and
length of the original pipe. Allowance should be made for circumferential stretching during installation.
d) The outside layer of the Tube shall be coated with an impermeable, flexible membrane that will contain the
resin and allow the resin impregnation (wet out) procedure to be monitored.
e) The Tube shall contain no intermediate or encapsulated elastomeric layers. No material shall be included in
the Tube that may cause delamination in the cured CIPP. No dry or unsaturated layers shall be evident.
f) The wall color of the interior pipe surface of CIPP after installation shall be a relatively light reflective color so
that a clear detailed examination with closed circuit television inspection equipment may be made.
g) Seams in the Tube shall be stronger than the non-seamed felt material.
h) The Tube shall be marked for distance at regular intervals along its entire length, not to exceed 5 ft. Such
markings shall include the Manufacturers name or identifying symbol.
i) Resin - The resin system shall be a corrosion resistant polyester or vinyl ester system including all required
catalysts, initiators that when cured within the tube create a composite that satisfies the requirements of
ASTM F1216, ASTM D5813 and ASTM F1743, the physical properties herein, and those which are to be
utilized in the submitted and approved design of the CIPP for this project. The resin shall produce a CIPP
that will comply with the structural and chemical resistance requirements of this specification.
Waterstop
A non-metallic, non-bentonite “hydrophilic” chloroprene rubber water stop shall be provided on all sanitary sewer
mains, 15- inch or greater, during the pipelining process. Moisture-activated, the water stop shall increase in size to
Standard Form of Informal Contract and General Conditions Page 5 of 49
This page summarizes the opportunity, including an overview and a preview of the attached documents.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Follow Design-Bid-Build (DBB) SOF Marine Raider Facilities Complex, Marine Corps Base (MCB) Camp

DEPT OF DEFENSE

Bid Due: 6/29/2026

Follow Infantry Platoon Battle Course (IPBC) Fort Bragg, North Carolina Active Contract Opportunity

DEPT OF DEFENSE

Bid Due: 6/15/2026

DESIGN-BUILD (DB) BARRACKS INITIATIVE (PACKAGE #1), MARINE CORPS AIR STATION (MCAS) CHERRY POINT,

Federal Agency

Institution Winston-Salem State University Institution URL for Additional Information about this Project (Optional)

North Carolina State University

Bid Due: 6/10/2026