4310--FY25 Condenser Water Pumps Lake Nona CEP
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Virginia |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Mar 19, 2025 |
| Due Date: | Mar 21, 2025 |
| Solicitation No: | 36C24825Q0556 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Mar 19, 2025 10:58 am EDT
- Original Response Date: Mar 21, 2025 04:00 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: May 20, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 4310 - COMPRESSORS AND VACUUM PUMPS
-
NAICS Code:
- 333914 - Measuring, Dispensing, and Other Pumping Equipment Manufacturing
-
Place of Performance:
Orlando VA Healthcare System 13800 Veterans Way Orlando , 32827
The Network Contracting Office (NCO) 8, Orlando VA Medical Center (OVAMC) is seeking to identify interested contractors who can manufacture or provide the required equipment to replace our existing Vertical Turbine Pumps with the below salient characteristics.
Head Shaft Assembly:
1.69 - 10TPI x 59 Long
STD BRZ- Packing Gland
Discharge Head:
Model: HI PRO (CI) W/16.5 & 20.0 BD
12 - Ansi Class 125-FF Discharge Flange
Column:
12 x 0.330 Wall THD - Yes
Line Shaft- Open
Shaft Diameter 1.69 TPI- 10tpi
Bowl:
2- Stage K20HC- Bowl Assembly
Flow- 5280 GPM 105 TDH Head
Strainer- Yes Type of Strainer- Basket
Materials:
Bowls- CI
Impellers- 316ss
BWL SFT- 416ss
Collets- 316ss
Bowl BRG- Bowl Dwg
Bolting- SS
Sole Plate- Fab Steel
Bowl WR- Bronze
Head Shaft- 416ss
Bowl Surface Finish- STD Paint: OD
Column Surface Finish- STD Paint: OD
Head Surface Finish- STD Paint: OD
Column- A53, GR B
Column CPLG- DI
BRG RET- BZ
Line SFT BRGS- Rubber
Line Shaft- SS (416)
Shaft CPLG- SS (304)
Packing- Graphite
Strainer- Bronze
Head- CI
Head Shaft CPG- 304 SS
The capability statement shall be limited to no more than five pages and must clearly state the following: Capability in industry to manufacture or provide the required equipment to replace our existing Vertical Turbine Pumps. Offerors who cannot provide historical information for their company regarding the requirements outlined above or similar scope and scale should provide corresponding information to show how the company would meet OVAMC requirements. This information should provide a strong level of confidence to the Government that an offeror would meet or exceed the performance requirements to provide all the requirements to provide the required equipment to replace our existing Vertical Turbine Pumps.
In addition, provide and answer the following:
Company name, address, point(s) of contact, title, telephone number, fax number, email address, cage code, and SAM UEI number.
Company s business size, to include number of employees;
Company s socioeconomic status
Ability to provide a product manufactured by a small business
THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposal (RFQ); submission of any information in response to this market survey is purely voluntary; the Government assumes no financial responsibility for any costs incurred.Â
To be eligible for award, prospective must be registered in the System for Award Management (SAM) Interest site, www.sam.gov.
Responses to this notice should be emailed, no later than 1600 hours (4:00 PM), Eastern Standard Time on March 21, 2025.
Telephone and facsimile responses will not be considered.
Please email: Jesus Carrillo at jesus.carrillo@va.gov. When responding via email ensure the subject line is titled with RFI# 36C24825Q0556 FY25: Condenser Water Pumps Lake Nona CEP.
No other information is available at this time and questions will not be entertained. We thank you for your interest and time to the prepare and submit a response.
- 8875 HIDDEN RIVER PARKWAY
- TAMPA , FL 33637
- USA
- Jesus Carrillo
- jesus.carrillo@va.gov
- Phone Number 407-646-5500 24205
- Mar 19, 2025 10:58 am EDTSources Sought (Original)
Related Document
| Apr 4, 2025 | [Solicitation (Original)] Lakemont & Viera Contract Replacement of Eaton Electrical Cabinets |
See Also
IFB 27-073-6144 Air Compressors and Install at Sat... Status: Open IFB 128098 City
State Government of Virginia
Due by 9/30/2026
Follow Towable Diesel Air Compressor Active Contract Opportunity Notice ID 47QACA26AIRCOMP Related Notice
GENERAL SERVICES ADMINISTRATION
Due by 9/15/2026
Follow John H. Kerr and Philpott Sump Pumps Active Contract Opportunity Notice ID
DEPT OF DEFENSE
Due by 9/25/2026
Follow Towable Diesel Air Compressor Active Contract Opportunity Notice ID 47QACA26AIRCOMP Related Notice
GENERAL SERVICES ADMINISTRATION
Due by 9/15/2026