6515--436 Fort Harrison VA Medical Center A/B Scanner for Opthalmology
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Montana |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Jul 30, 2025 |
| Due Date: | Aug 13, 2025 |
| Solicitation No: | 36C25925Q0681 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- Original Published Date: Jul 30, 2025 02:11 pm MDT
- Original Date Offers Due: Aug 13, 2025 12:00 pm MDT
- Inactive Policy: Manual
- Original Inactive Date: Oct 12, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
-
NAICS Code:
- 339112 - Surgical and Medical Instrument Manufacturing
-
Place of Performance:
Dept. of Veterans Affairs Fort Harrison VA Medical Center Fort Harrison , MT 59636USA
DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Response Instructions:
Do not provide more than 8 pages, including cover letter page.
Submit your response via email to: barron.long@va.gov
Submit your response NLT 12:00 (MST) on Wednesday, August 13th
Mark your response as Proprietary Information if the information is considered business sensitive.
VA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;
Information Requested from Industry:
In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List. Vendor Name:
SAM UEI #:
Name of Manufacturer:
Manufacturer Address:
Manufacturing Country of Origin
Estimated Delivery Time:
___________________________________________________
SAC FSS contract number
Vendor Point of Contract (POC) Name
POC Phone Number:
POC Email Address:
STATEMENT OF WORK (SOW)
as of 07/21/2025
2. Contract Title. New A/B Scan for Billings Ophthalmology
3. Background.
The A/B Scan for measuring axial length of the eye and thickness of the retinal layers or lesions, in Billings quit working and is beyond end of life so no parts are available for repairs.
4. Scope.
Procure a new A/B Scan for Billings Ophthalmology that is on the approved list of equipment for FORUM compatibility as the interface is already in place across VA Montana.
5. Specific Tasks.
A/B scan instrument MUST be on the approved list of equipment for Forum compatibility must have an ERA and be Vista Approved
Must have DICOM compliance capability.
A/B scan probes must be detachable so it can be processed by SPS in accordance with our disinfecting policy.
Must have A-scan and B-scan options for measuring eye length and retinal thickness or lesion thickness.
Due to space constraints of room equipment will be utilized in, need a single unit with interchangeable probes no larger than 15 x15 footprint.
Due to limited space constraints and sensitive electrical equipment, must be direct contact A-scan NOT immersion for obtaining readings.
Needs foot pedal to obtain readings so do not have to resituate while taking readings.
Must plug into standard US outlet.
Must be MADE IN THE USA
Manufacturer must set up equipment and provide instructional training to provider and technicians. Task 1 - Enterprise Management Controls.
Subtask 1 A/B Scan equipment and software must be compatible with Forum which is in place across VA Montana. Instrument will be used to take axial length, anterior chamber depth, white to white, and lesion thickness measurements, then transmit those measurements to the VA internal platform Forum where they can be assessed by the doctor. There is a specific list of approved devices that have been validated through the VistA database for compatibility with Forum. Any equipment that is not on the list is not guaranteed to work with Forum which is established and utilized throughout VA Montana, and the rigorous testing process to see if a piece of equipment is compatible take almost 12 months.
Security Requirements
Interfaces with Forum an internal storage platform that is already in use across VA Montana.
7. Place of Performance.
Will be in the Billings VA Ophthalmology Clinic to be used by the ophthalmologist or ophthalmology technician on staff for measurements unable to be obtained by IOL master or OCT or to get an idea of retinal layers when view into eye is obstructed.
8. Delivery Schedule.
Contracted vendor will deliver to Billings VA (Benjamin Steele) and coordinate with Biomed for installation in the exam room on a date when the doctor is not seeing patients. Once the instrument has been set up Biomed with work with Ophthalmology department to schedule a training with the manufacturer to provide education on functionality and performance. LINE ITEM:
QTY 1: VUPAD B-SCAN/A-SCAN SYSTEM WITH ULTRASOUND DICOM MODULE
- 6162 S WILLOW DR SUITE 300
- Greenwood Village , CO 80111
- USA
- Barron Long
- barron.long@va.gov
- Phone Number 303-712-5741
- Jul 30, 2025 02:11 pm MDTCombined Synopsis/Solicitation (Original)
See Also
Intent to Sole Source Picarro Inc. Intent to Sole Source G2401-m: High-Precision GHG
State Government of Montana
Due by 9/24/2026
Follow CSU BD infusion pumps Active Contract Opportunity Notice ID 75H70926BAO_093 Related Notice
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Due by 9/20/2026
Intent to Sole Source for InSight X3 Dual-067 Intent to Sole Source for
State Government of Montana
Due by 9/15/2026
Wheelchair Lift for SouthWestern Montana Veterans Home The Department of Public Health and
State Government of Montana
Due by 10/01/2026