Fire Trainer Liner
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | North Carolina |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Jul 21, 2026 |
| Due Date: | Jul 30, 2026 |
| Solicitation No: | FA480926Q0065 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Presolicitation (Updated)
- Updated Published Date: Jul 21, 2026 10:42 am EDT
- Original Published Date: Jul 15, 2026 03:33 pm EDT
- Updated Response Date: Jul 30, 2026 02:00 pm EDT
- Original Response Date: Jul 30, 2026 02:00 pm EDT
- Inactive Policy: 15 days after response date
- Updated Inactive Date: Aug 14, 2026
- Original Inactive Date: Aug 14, 2026
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 4240 - SAFETY AND RESCUE EQUIPMENT
-
NAICS Code:
- 238990 - All Other Specialty Trade Contractors
-
Place of Performance:
Goldsboro , NC 27531USA
SALIENT CHARACTERISTICS
for
Structural Trainer Liner
DESCRIPTION: Replace liner inside the structural trainer
REQUIREMENTS: The liner components units shall:
1. Designed to meet all referenced safety, thermal, and regulatory specifications, this specific material is engineered for extreme live-fire training evolutions.
2. Specifically formulated for Class A, B, C, D, Electrical, and F/K fires within a controlled burn cell which complies with NFPA 1402 and related standards.
3. Made of a cementitious high temp composite formula, which has a negative health impact when installed by certified installers.
4. Have Kevlar additives
5. Unique tongue and groove installation method
6. Stainless Steel mounting hardware
7. Have five (5) to ten (10) year warranty to replace
8. Able to withstand 150 psi nozzle forces
9. 1.5 inches thick requires no additional insulation behind its barrier
10. Heat transfer 10.4% (1000 degree / 140 degree in 10 minutes)
11. Complies with all NFPA suggested burn matrix formulas
12. Certified as a protective skin for flammable hazmat storage cells
- ADMIN ONLY NO REQTN CP 919 722 1705 1570 WRIGHT BROTHERS AVE BLDG 2903
- SEYMOUR JOHNSON AFB , NC 27531-2456
- USA
- Michael A. Berg
- michael.berg.6@us.af.mil
- Phone Number 9197221670
- Ryan Rhea
- ryan.rhea.2@us.af.mil
- Jul 21, 2026 10:42 am EDTPresolicitation (Updated)
- Jul 15, 2026 03:33 pm EDT Presolicitation (Original)
Related Document
| Jul 15, 2026 | [Presolicitation (Original)] Fire Trainer Liner |
See Also
DC00495_BRUNSWICK FALL RESURFACING POC DC00495_BRUNSWICK FALL RESURFACING DC00495_Brunswick Fall Resurfacing_Plan Set_Revised 081326.pdf Doc.
Division of Highways
Due by 9/17/2026
DC00480_SAMPSON FALL RESURFACING 1 POC DC00480_SAMPSON FALL RESURFACING 1 DC00480_ITB.pdf Doc. Type: Invitation
Division of Highways
Due by 9/17/2026
Solicitation Number: 63-DMP1193929 Project Title: Fire Extinguisher Purchases / Services / Inspections Description:
State Government of North Carolina