Fire Station Alerting and Alarm (FSAA) System

Agency: DEPT OF DEFENSE
State: Federal
Type of Government: Federal
FSC Category:
  • 63 - Alarm, Signal, and Detection Systems
NAICS Category:
  • 561621 - Security Systems Services (except Locksmiths)
Posted Date: Mar 17, 2026
Due Date: Mar 24, 2026
Solicitation No: FA527026Q0006
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

Follow
Fire Station Alerting and Alarm (FSAA) System
Active
Contract Opportunity
Notice ID
FA527026Q0006
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
PACIFIC AIR FORCES
Office
FA5270 18 CONS PK
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Mar 17, 2026 01:57 pm JST
  • Original Response Date: Mar 24, 2026 01:00 pm JST
  • Inactive Policy: 15 days after response date
  • Original Inactive Date: Apr 08, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6350 - MISCELLANEOUS ALARM, SIGNAL, AND SECURITY DETECTION SYSTEMS
  • NAICS Code:
    • 561621 - Security Systems Services (except Locksmiths)
  • Place of Performance:
    Okinawa , JP-47
    JPN
Description

1.0 PURPOSE



The purpose of this Sources Sought Request for Information (RFI) is for market research purposes only. The Government is seeking to identify all responsible sources capable of providing a complete fire station alerting and alarm (FSAA) solution that can fully integrate with the Government's existing communications and 911 infrastructure. The objective is to understand the current market's capability to meet a series of integration requirements outlined below.



2.0 BACKGROUND & CRITICAL INTEGRATION CONSTRAINTS



The Government currently operates a public safety ecosystem built upon several existing platforms. Any new solution must seamlessly and natively integrate with this specific infrastructure.



This market research is specifically intended to assess the ability of commercial solutions to integrate with the following:





  1. Redundant Alerting via LMR Network: The solution must provide alerting notifications through both IP-based networks and, for redundancy, directly through the INDOPACOM IP2LMR trunking system (a Motorola Pacific-wide LMR network). The solution must also interface directly with existing Motorola MCC7500 dispatch consoles.




  2. Native VESTA 911 Integration: The proposed Computer-Aided Dispatch (CAD) system must integrate directly and natively with the VESTA 911 system managed by the program office at Hill AFB. The solution must not require dispatchers to use a separate, secondary system or screen for 911 data, but must instead ingest data directly from VESTA to reduce workflow steps.




  3. Native C2 via LMR Network: The proposed Command & Control (C2) software must provide real-time situational display of mobile fire units by pulling location data directly from radios operating on the current Motorola LMR radio network.




  4. Existing Inter-Agency Video Architecture: The proposed video surveillance system must be able to natively integrate into the existing Avigilon video hardware/software architecture utilized by partner units, allowing for the direct sharing and control of video feeds without additional third-party software, gateways, or licensing fees.





3.0 SCOPE OF REQUIREMENT (For Informational Purposes)



The Government is seeking information on solutions that provide the following capabilities, or functionally equivalent alternatives, subject to the constraints in Section 2.0:





  • Fire Station Alerting System (4 Stations)




  • Computer-Aided Dispatch (CAD) System (Primary/ALT Dispatch)




  • Video Surveillance System (4 Stations)




  • Command & Control (C2) Software (Primary/ALT Dispatch)




  • Supporting Infrastructure: Including VESTA-compatible workstations, network backhaul equipment, display boards, ergonomic dispatch furniture, and UPS.




  • Turnkey Services: Including installation, systems integration, testing, and development of as-built drawings.





4.0 INFORMATION SOUGHT FROM INDUSTRY



Interested parties are requested to provide a capability statement that specifically and directly addresses the following:





  1. Company Profile: Company name, address, CAGE code, UEI number, and business size status.




  2. General Capability: A summary of your ability to provide the overall scope of equipment and services, to include your certification to perform the required work.




  3. Response to Critical Integration Constraints (CRITICAL):





    • LMR Alerting & Console Integration: Describe your solution's capability to provide redundant alerting through the INDOPACOM IP2LMR trunking system. Detail your technical approach for native interfacing with Motorola MCC7500 consoles without requiring console replacement.




    • VESTA Integration: Provide evidence (e.g., case studies, technical documentation) of your CAD system's proven, native integration with the VESTA 911 platform.




    • C2 LMR Integration: Explain the technical method your C2 software uses to pull real-time location data directly from radios on a proprietary Motorola LMR network.




    • Avigilon Integration: Detail your video system's capability to natively integrate with an existing Avigilon architecture, allowing partner agencies to view/control feeds without additional software or licensing.






  4. Product Line & Approach: Briefly describe the products that could meet the requirements. Explain your approach to providing a turnkey solution and taking sole responsibility for the successful integration and compatibility of all components.




  5. Industry Feedback: Any professional feedback on the feasibility or challenges associated with meeting the integration constraints described in Section 2.0.





5.0 DISCLAIMER



This is a Request for Information (RFI) for market research purposes only and does not constitute a solicitation. The Government does not intend to award a contract on the basis of this RFI or to otherwise pay for the information solicited.


Attachments/Links
Contact Information
Contracting Office Address
  • (ADMIN ONLY NO REQTN) UNIT 5199
  • APO , AP 96368-5199
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Mar 17, 2026 01:57 pm JSTSources Sought (Original)
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Follow 63--CONTROL UNIT,ALARM Active Contract Opportunity Notice ID N0010426REB68 Related Notice Department/Ind. Agency

DEPT OF DEFENSE

Due by 9/24/2026

Steven M. Clouse WRC Biosolids System Upgrades Solicitation No. CO-00900-SM Status: Currently Accepting

San Antonio Water System

Due by 9/22/2026

Follow Intent to Sole Source ADVANTOR IDS Active Contract Opportunity Notice ID PANNGB26P0000039907

DEPT OF DEFENSE

Follow CONTROL,ALARM Active Contract Opportunity Notice ID N0010426QEC83 Related Notice Department/Ind. Agency DEPT

DEPT OF DEFENSE

Due by 9/21/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.