F103--Legionella and Critical Water Systems Sample Analysis
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Arkansas |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Feb 24, 2026 |
| Due Date: | Mar 6, 2026 |
| Solicitation No: | 36C25626Q0432 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Feb 24, 2026 09:18 am CST
- Original Response Date: Mar 06, 2026 08:00 am CST
- Inactive Policy: Manual
- Original Inactive Date: May 05, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: F103 - ENVIRONMENTAL SYSTEMS PROTECTION- WATER QUALITY SUPPORT
-
NAICS Code:
- 541380 - Testing Laboratories and Services
-
Place of Performance:
Department of Veterans Affairs Central Arkansas Veterans Healthcare System NORTH LITTLE ROCK ,USA
The John L. McClellan Memorial Veterans Hospital located at 4300 West 7th Street, Little Rock, AR and the Eugene Towbin Medical Center located at 2200 Fort Roots Drive, North Little Rock, AR, known as Central Arkansas Veterans Healthcare System (CAVHS), is seeking a qualified contractor who can fulfill a requirement to furnish all reports, labor, management, equipment, supplies, transportation, applicable licenses, certifications, and accreditations necessary to complete Legionella and Critical Water Systems Sample Analysis. No Government equipment will be used by the Contractor.
Testing Requirements:
Legionella Sample Analysis
Contractor shall comply with VHA Directive 1061 Prevention of Healthcare Associated Legionella Disease and Scald Injury from Water Systems dated February 2, 2022, AMENDED September 26, 2022. All Legionella sample analysis must be performed by a laboratory that is current and up to date with the CDC ELITE Program.
Polymerase Chain Reaction (PCR) will be the primary method of analysis for Legionella in water samples collected at CAVHS.
All Legionella samples analyzed via PCR that have positive Legionella results, or the results are reported as indeterminate must be analyzed via the ISO Culture Method completed to verify the results of the PCR analysis.
Contractor shall provide all items necessary for proper shipment of samples, to include, but not limited to, all collection bottles, shipping containers, labels, and ice pack. Contractor must cover the cost incurred to ship these items to the facility.
Contractor shall provide overnight shipping labels for samples to be shipped via overnight shipping on the same day they are collected.
Critical Water System Sample Analysis
Sterile Processing Service (SPS) all samples collected from SPS musted be analyzed IAW ANSI/AAMI ST108 Water for the processing of medical devices.
Dental Unit Water Lines (DUWL) all samples collected from DUWL must be analyzed by a standard which will allow for colony forming units (CFU) count of 500cfu/milliliter(mL).
Estimated Number of Samples to be analyzed annually:
Type of Samples
Estimated # of Annual Samples
Annual # of Samples not to Exceed
Legionella Potable Water (PCR)
600
800
Legionella Cooling Tower (PCR)
Legionella Chiller (PCR)
Legionella ISO Plate Method Validation
150
400
Dental Unit Water Line (DUWL)
950
1000
SPS Critical Water Bacterial (HPC)
275
700
SPS Critical Water Endotoxin
100
700
SPS Critical Water Ionic Contaminants
40
150
SPS Critical Water TOC
40
150
SPS Critical Water Total Hardness
40
150
SPS Critical Water Total Alkalinity
40
150
SPS Critical Water Conductivity
40
150
Research VMU (HPC) - LR
2
4
Total Number of Samples
2277
4354 Important Information: The Government is not obligated to - nor will it pay for or reimburse any costs associated with responding to this sources-sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service-Disabled Veteran Owned Small Business set aside. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 541380 -Testing Laboratories and Services - with a size standard of $19 Million.
Notice to Potential Offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM). Additionally, all Service Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be VetCert certified by the SBA located at Veteran Small Business Certification (sba.gov) . All interested Offerors should submit information by e-mail to: arlene.blade@va.gov. All information submissions shall include in the Subject Line of the email, Sources Sought Notice 36C25626Q0432 - Legionella and Critical Water Systems Sample Analysis and should be received no later than March 6, 2026 at 8:00 am CST.
All information contained in this Sources Sought is preliminary as well as subject to modification and is in no way binding on the Government. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract. If a solicitation is released, it will be synopsized on Contracting Opportunities (https://beta.sam.gov/) website or GSA. It is the responsibility of the interested parties to monitor these sites for additional information pertaining to this Sources Sought, or future RFP/RFQ.
DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
- 715 SOUTH PEAR ORCHARD RD., PLAZA 1
- RIDGELAND , MS 39157
- USA
- Arlene A. Blade
- arlene.blade@va.gov
- Phone Number (318) 466-4281
- Feb 24, 2026 09:18 am CSTSources Sought (Original)
See Also
NOTICE TO BIDDERS ELM TREE ROAD SIDEPATH TRAILBLAZERS Invitation For Bid (IFB)-26-08 The
Arkansas Democrat-Gazette
Due by 9/29/2026
National Audubon Society, Inc. dba Little Rock Audubon Center 4500 Springer Blvd., Little
Arkansas Democrat-Gazette
Due by 9/30/2026
Bid Number: HS-26-063 Bid Title: Removal of Infrastructure from City County Tower on
City of Hot Springs
Due by 10/12/2026
Bid Number & Description: UCA-27-033 RFP Mitigation Services Opening Date: October 6th, 2026
University of Central Arkansas
Due by 10/06/2026