Equipment for Generating Radiated Electrical Signals
| Agency: | ENERGY, DEPARTMENT OF |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Nov 13, 2024 |
| Due Date: | Dec 9, 2024 |
| Solicitation No: | FMP-NNL-0038 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Updated)
- Updated Published Date: Nov 12, 2024 12:33 pm EST
- Original Published Date: Nov 08, 2024 11:00 am EST
- Updated Response Date: Dec 09, 2024 05:00 pm EST
- Original Response Date: Dec 09, 2024 05:00 pm EST
- Inactive Policy: Manual
- Updated Inactive Date: Dec 10, 2024
- Original Inactive Date: Dec 10, 2024
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: AG12 - ENERGY R&D SERVICES; ENERGY SUPPLY; APPLIED RESEARCH
-
NAICS Code:
- 541715 - Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
-
Place of Performance:
USA
Equipment for Generating Radiated Electrical Signals
Suppliers are being sought for equipment and approaches to deal with electronic noise, as described herein.
Symptom: Electronic noise in a production environment, such as radiated electrical signals from nearby welding, grinding or equipment start-up, can effect coaxial cables supplying sensitive measurement equipment, causing erroneous signals. Although the spurious signals are on the order of 10-11 amps and might be considered insignificantly small for many applications, their appearance in sensitive nuclear plant instruments is problematic. This happens most commonly during production, maintenance or plant start/stop operations.
Cause & Context: Radiated electric and magnetic fields from production operations or from equipment transients (starts and stops) are to be expected. These fields can induce currents in cables connected to nearby sensitive measurement instruments. However, the operation causing offending electronic noise in a particular instrument is not always evident. In addition, the reason spurious signals are seen in one instrument but not others of similar design, construction and location is not always evident. Troubleshooting is time consuming and expensive and can impact critical path schedules.
Repair and mitigation steps are also time consuming and expensive, as the effected cables are often in hard-to-access locations. Technology to help eliminate the susceptibility of co-axial cables to radiated electrical noise, and/or to speed up the troubleshooting process, is being sought.
Desired End State: A near-term end state in which new tools are available to replicate the current-inducing characteristics of the operations cited above is the primary objective. This will allow testing to determine the vulnerability of a particular cable/instrument, without impacting critical path schedules.
A near-term end state in which faster alternatives to current mitigation methods are available is a second objective. Current methods usually involve shielding with metal sheets or foils, replacing cables or re-cleaning cable connections.
A long-term end state in which cables can be made immune to radiated signals is desirable. A long-term end state in which the vulnerability of cables to radiated signals can be quickly assessed using readily available or easy-to-obtain information is also desirable.
Candidates: The solution of most immediate interest would be a portable device capable of generating electrical noise to help identify susceptible coaxial cables early in the production or maintenance process. Such a device would have the following characteristics:
- Can fit through a 30” diameter opening
- Have an antenna (loop) capable of reaching in areas with minimal clearance, able to extend up to 20 feet
- Variable signal strength and frequency from 15 Hz to 60 kHz
- Target co-axial cable signal strength is typically between 10-10 to 10-11 amps or discrete counts (pulses).
- The target co-axial cable is Mil Standard M17/233-00001 or M17/126-RG391 (98) contained within conduit with a minimal number of connectors.
- Naval Nuclear Laboratory, c/o Fluor Marine Propulsion, LLC P.O. Box 1072
- Schenectady , NY 12301
- USA
- Jon Ruffley
- Jonathan.Ruffley@unnpp.gov
- Nov 12, 2024 12:33 pm ESTSources Sought (Updated)
- Nov 08, 2024 11:00 am EST Sources Sought (Original)
Related Document
| Nov 11, 2024 | [Sources Sought (Original)] Equipment for Generating Radiated Electrical Signals |
| Nov 13, 2024 | [Sources Sought (Updated)] Equipment for Generating Radiated Electrical Signals |
| Dec 4, 2024 | [Sources Sought (Updated)] Equipment for Generating Radiated Electrical Signals |
| Jan 23, 2025 | [Sources Sought (Updated)] Equipment for Generating Radiated Electrical Signals |
| Feb 19, 2025 | [Sources Sought (Updated)] Equipment for Generating Radiated Electrical Signals |
See Also
Follow Code 34 Engineering Services for Electronic Warfare (EW) and Electromagnetic (EM) Special
DEPT OF DEFENSE
Due by 9/24/2026
Follow Environmental Security Technology Certification Program (ESTCP) - Energy and Environmental Technology Demonstrations
DEPT OF DEFENSE
Due by 8/20/2027
Follow Automated Processes for Knowledge Discovery and Information Retrieval Active Contract Opportunity Notice
DEPT OF DEFENSE
Follow NEW - Air Force Installation and Mission Support Center (AFIMSC) Streamlining Procurement
DEPT OF DEFENSE
Due by 8/29/2030