Environmental Chamber
| Agency: | ENERGY, DEPARTMENT OF |
|---|---|
| State: | Tennessee |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Nov 26, 2024 |
| Due Date: | Dec 19, 2024 |
| Solicitation No: | PR329505 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Original)
- Original Published Date: Nov 26, 2024 09:15 am EST
- Original Date Offers Due: Dec 19, 2024 02:00 pm EST
- Inactive Policy: 15 days after date offers due
- Original Inactive Date: Jan 03, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6636 - ENVIRONMENTAL CHAMBERS AND RELATED EQUIPMENT
-
NAICS Code:
- 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
-
Place of Performance:
Oak Ridge , TN 37830USA
Environmental Chamber
Company requires the design and installation of a 60,000 to 300,000 Btu/h automated air enthalpy chamber. For the operation of this apparatus, the upper chamber will be operated over an ambient temperature range of -32 to 66°C (-25 to 150°F) and the lower chamber must simulate a wide range of indoor temperatures from 7 to 66°C (45 to 150°F). The chamber is to be a stacked configuration with an overall height of 26 feet with the upper chamber 14 feet tall and the lower chamber 12 feet tall. The floor area for both upper and lower chambers is to be 22 feet by 22 feet. The facility shall conform to the instruments and test requirements and provide the conditions specified in the attached document. The facility will use either the Outdoor Air Enthalpy or the Refrigerant Enthalpy method as the Standard Test Method secondary check to the performance results as prescribed in ASHRAE 37.
Airflow tunnels (code testers) should be supplied for both chamber rooms. The code testers should be integrated with the automated end-to-end DAS and provide required level of accuracy, ease of use and reliability. The code testers shall be designed and constructed in accordance with ASHRAE 37 by the Seller.
See attached: "Environmental Chamber Combined Docs" for further details.
- Oak Ridge National Laboratory PO Box 2008
- Oak Ridge , TN 37831
- USA
- Laura Hyden
- Hydenln@ornl.gov
- Phone Number 865-341-4201
- Nov 26, 2024 09:15 am ESTSolicitation (Original)
See Also
Follow Keithley Instruments/Tektronix, Picoammeter/Voltage Source, and Calibration Active Contract Opportunity Notice ID RFQSS496408
ENERGY, DEPARTMENT OF
Due by 9/18/2026
Follow Keithley Instruments/Tektronix, Picoammeter/Voltage Source, and Calibration Active Contract Opportunity Notice ID RFQSS496408
ENERGY, DEPARTMENT OF
Due by 9/18/2026
Organic Polymer RFP Number: TC2027-03 Start Date: 08/19/2026 10:50 AM Close Date: 10/07/2026
Town of Collierville
Due by 10/07/2026
Follow ErBCO Film Active Contract Opportunity Notice ID PR497343 Related Notice Department/Ind. Agency
ENERGY, DEPARTMENT OF
Due by 9/17/2026