| Agency: | Peace River Electric Cooperative |
|---|---|
| State: | Florida |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Apr 14, 2025 |
| Due Date: | Apr 15, 2025 |
| Solicitation No: | 2025-02 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
| Date | Time | Mandatory | Location |
| # | Required | Group | Make | Model | Description | Quantity | Unit of Measure | Price/ Percent | Type |
| Question | Date Asked | Answer | Date Answered |
| PRECO uses ArcGIS as a platform. Field Maps is an app from this platform that captures before and after images. These are needed for FEMA documentation. The hours of operation depend on how catastrophic the storm is. There is not really a set amount requested, only time worked to complete the project. As far as Drones, PRECO will need to have the assessment done quickly due to the amount of personnel coming in to do the restoration. PRECO currently has 3386 miles of OH line covering 10 counties. The drone may not be an effective way to assess it. I believe this covers all your questions. If not, please don`t hesitate to reach out. | 2/17/2025 2:22:15 PM | ||
| Lodging and Fuel will be provided once your team has been registered into PRECO`s Storm Registration. | 3/10/2025 10:10:14 AM | ||
|
Does PRECO just want assessment from still photography or would other methods be utilized (LiDAR, Thermal Analysis, Video, etc.)
Still Photography is what PRECO is after. |
3/21/2025 2:12:30 PM | ||
|
What level of detail is PRECO expecting from the storm assessment data? (Do you want to see downed poles, for example, or full inspection capable of identifying broken insulators?)
PRECO expects before images of the damages sustained and after pics of the damages repaired. This would include poles down, leaning poles, conductors down, ROW, and such. |
3/21/2025 2:32:16 PM | ||
|
The maximum distance from the pole should be no more than 75 feet, and the maximum elevation of the pole should be no greater than 25 feet above.
Just assessment still photography. Daily would be preferable. We need a dump of photographs and a corresponding spreadsheet that includes the following information: a. X coordinate b. Y coordinate c. Z coordinate d. Heading e. Date of Photo f. Time of Photo g. Unique Identifier of Vehicle |
3/24/2025 7:40:12 AM | ||
|
Is PRECO using the minimum of ten (10) years distribution utility experience as a hard line for the damage assessors and area field manager experience?
Answer: PRECO prefers experience and knowledge in the distribution field. It best explains the contractor`s needs in section 12 of this agreement. |
4/4/2025 8:57:02 AM |
| Code | Description |
| [905-4] | Aerial Photogrammery Services |
| [905-5] | Aerial Photography |
| [905-14] | Airplane/Helicopter Services (Not Otherwise Classified) |
| Publication | Date |
With Free Trial, you can:
You will have a full access to bids, website, and receive daily bid report via email and web.
Description: Convention Center - Cooling Tower Water Line Replacement (RE Department: Facilities Development
Palm Beach County
Bid Due: 6/22/2031
Description: Summit Library Administration Renovations Department: Procurement Buyer: Jeromy Calderon Solicitation Number: RPQ-680-F25-0090/JC-1-1
Palm Beach County
Bid Due: 8/14/2030
Follow Z1DA--FY26: NRM (PROJ: 548-23-112) BB Upgrade Exterior Signage and Wayfinding Active Contract
VETERANS AFFAIRS, DEPARTMENT OF
Bid Due: 6/03/2026
Follow Cape Canaveral National Cemetery Ornamental Grass Renovation and Irrigation National Shrine Project
VETERANS AFFAIRS, DEPARTMENT OF
Bid Due: 6/23/2026