Design of Lift Station #60 Rehab & Upgrade

Agency: State Government of Florida
State: Florida
Type of Government: State & Local
NAICS Category:
  • 236220 - Commercial and Institutional Building Construction
  • 238210 - Electrical Contractors and Other Wiring Installation Contractors
  • 238990 - All Other Specialty Trade Contractors
Posted Date: Jun 2, 2026
Due Date: Jun 26, 2026
Solicitation No: RFP-16143
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Request for Proposals Design of Lift Station #60 Rehab & Upgrade Central Florida Tourism Oversight District
Advertisement Status: OPEN
Last Edit Date/Time: 06/02/2026, 01:59 AM
Advertisement Number: RFP-16143
Agency Advertisement Number: C007098
Version Number: 1
Published Date/Time: 06/02/2026 01:59 AM
Start Date/Time: 06/02/2026 01:59 AM
End Date/Time:  06/26/2026 03:00 AM
Commodity Codes
Code Description
81101500 Civil engineering
81101505 Structural engineering
81101527 Wastewater engineering
81101528 Stormwater engineering
81101600 Mechanical engineering

The Central Florida Tourism Oversight District (“District”) is seeking professional engineering services to design and develop plans and technical specifications for the rehabilitation and upgrade of Lift Station #60 (LS-60) located on the western side of Disney's Animal Kingdom adjacent to a stormwater pond.

The general scope includes addition of a permanent, independently powered surface-mounted backup pump capable of pumping full design flow, removal of the existing backup generator, along with full rehabilitation to all electrical and mechanical components. Including, but not limited to:

A. Preliminary engineering report, comprehensive design, permitting, and construction services.
B. Design a bypass pumping system to maintain continuous station operations during rehabilitation activities.
C. Assess and replace electrical control panel with alternative for adding conditioned electrical structure onsite.
D. Assess the need and placement of conditioning pumps (including but not limited to grinder/chopper, flush pumps, etc.) one for each of the two cells, and a mixer pump in the common influent channel.
E. Assess condition of influent gravity main (30”) and provide recommendation if lining is needed.
F. Install pump soft starters.
G. Install fall protection devices.
H. Install new diesel-powered emergency pump, controls, and piping and the removal of existing generator and controls.
I. Provide condition assessment and recommended repair and replacements for the above-ground crane system existing onsite.
J. Provide condition and performance assessment of all four (4) pumps.
a. Analyze current performance and runtimes versus original design points.
b. Provide recommendations for purchasing replacements or stock spares.
K. Replace lift station risers and bases.
L. Recoat wet well (two compartments totaling 21’) and upstream manhole.
M. Replace inoperable wet well isolation gates to restore intended use.
N. Replace existing isolation valves and discharge piping with an above-grade assembly to eliminate confined space entry requirements in the vault.
O. Replace various controls and appurtenances including floats, flow meter, wet well liquid level measurement device, air release valves, etc.
P. Replace and/or modify the supervisory control and data acquisition (SCADA) equipment.
Q. SCADA and controls coding shall support 24/7 monitoring of station operations, with real-time data communicated to the RCES control room using existing onsite radio and fiber systems.

Please direct all questions to:
Name: Karina Rodrigues
Phone: (689) 254-3170
Address: 1900 Hotel Plaza Blvs Lake Buena Vista, FL 32830
Email: krodrigues@oversightdistrict.org
Description Date/Time
MFMP Flyer Jun 2, 2026, 1:59:26 AM
For questions on a specific advertisement, contact the agency advertisement owner. Advertisements include the contact information for the agency advertisement. The agency advertisement owner is the point of contact for vendors with specific questions.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

RFQ-26-D-00030 26-D-00030 Ybor Pumping Station Force Main Repairs Design View Details Posted: Monday,

City of Tampa

Bid Due: 8/20/2026

Main Agency Orlando Utilities Commission Status Active Fiscal Year 2026 Primary Contact Robert

Orlando Utilities Commission

Bid Due: 8/11/2026

Project ID: 26-B-115JS Title: Ocean Center Parking Garage Level 3, 4 & 5

Volusia County

Bid Due: 8/27/2026

1412186879 (RFP) District II Building 6 Renovations - Design Phase The purpose of

JEA

Bid Due: 7/28/2026