DeCordova Bend Dam Bridge Load Rating IDIQ

Agency: State Government of Texas
State: Texas
Type of Government: State & Local
NAICS Category:
  • 237310 - Highway, Street, and Bridge Construction
  • 541330 - Engineering Services
Posted Date: Dec 3, 2025
Due Date: Jan 14, 2026
Solicitation No: RFP_No._26-1378
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

DeCordova Bend Dam Bridge Load Rating IDIQ
Solicitation ID:

RFP_No._26-1378

Status:

Posted

Contact Name:

Allison Sheeler

Contact Number:

(254) 761-3153

Contact Email:

Allison.Sheeler@Brazos.org

Response Due Date:

1/14/2026

Response Due Time:

10:00 AM

Agency/Texas SmartBuy Member Number:

K4600

Posting Requirement:

21+ Days for Solicitation Notice

Solicitation Posting Date:

12/3/2025

Last Modified:

12/3/2025 3:22 pm

Class/Item Code:

12025-Bridges, Passenger Loading;
92513-Bridge Engineering;

Solicitation Description:

The purpose of this RFP is to select an engineering firm(s) based on their qualifications and experience of the firm’s personnel to perform bridge load rating analyses at DeCordova Bend Dam. The Firm selected will enter into an Indefinite Delivery, Indefinite Quantity (IDIQ) Professional Services Contract and shall thereafter, upon request, perform bridge load rating services.

A general scope of services will be developed in conjunction with a cost reimbursable contract between the BRA and the selected Engineering Firm(s). The following is an overview of services that may be required, but not limited to:

a. Work with the BRA to develop a scope of services and not-to-exceed fee for proposed services a. for each project.

b. Review existing documentation.

c. Conduct site visit(s) as necessary to verify geometry, dimensions, material properties, and conditions not adequately documented.

d. Perform nondestructive testing where necessary to confirm material properties.

e. Perform load rating analyses in accordance with current AASHTO Manual for Bridge Evaluation and applicable TXDOT Load Rating Manual for equipment such as trucks, tractors, cranes, etc.

f. Analyze both inventory and operating ratings.

g. Develop bridge model(s).

h. Provide load rating summary report(s) that are signed and sealed by a qualified structural engineer licensed in the State of Texas.

i. Provide third party expert opinion for other load rating analyses for facilities throughout the Brazos River basin.

Work under the anticipated contract will be billed on a cost reimbursable basis. Hourly costs for Firms staff will be included as an attachment to the contract and will be changed only by prior approval of the BRA. Each specific assignment will be set out in a Service Order under the Contract, and the scope and not-to-exceed fee for such Service Order will be negotiated in advance and approved individually by the BRA.

Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Wichita Falls Generator Replacement Follow Solicitation Solicitation ID: 405-27R0002622 Status: Posted Contact Name:

State Government of Texas

Due by 11/26/2026

Electric Motors Follow Solicitation Solicitation ID: IW270104 Status: Posted Contact Name: Candice Johnson

State Government of Texas

Due by 11/12/2026

Follow Sources Sought -Building 493 Generator and Backup Power Installation- Red River Army

DEPT OF DEFENSE

Due by 11/13/2026

Project: Applied Information School Clocks with Solar D/C Back Panel Ref. #: 601310000103328

State Government of Texas

Due by 11/20/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.