DCS Plumbing Improvement Project - Wyandot Elementary School

Agency: Dublin City Schools
State: Ohio
Type of Government: State & Local
NAICS Category:
  • 236220 - Commercial and Institutional Building Construction
  • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
Posted Date: May 8, 2026
Due Date: May 19, 2026
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

DCS Plumbing Improvement Project - Wyandot Elementary School

Bids are due on or before 2pm EST on May 19th 2026

Legal Notice

Wyandot Plumbing Improvement Project- Bid  Specs

Wyandot Plumbing Improvement Project - Bid Drawing

Addendum 1 (5.8.26)

Attachment Preview

DRAWING INDEX
DWG NO. SHEET TITLE
COVER SHEET
P-001 GENERAL INFORMATION - PLUMBING
P-101 PARTIAL FIRST FLOOR PLAN - PLUMBING - DEMOLITION
P-102 PARTIAL FIRST FLOOR PLAN - PLUMBING
E-001 GENERAL INFORMATION - ELECTRICAL
E-101 PARTIAL FIRST FLOOR PLAN - ELECTRICAL - DEMOLITION
E-102 PARTIAL FIRST FLOOR PLAN - ELECTRICAL

DUBLIN CITY SCHOOL DISTRICT BOARD OF EDUCATION
DCS PLUMBING IMPROVEMENTS PROJECT
WYANDOT ELEMENTARY SCHOOL
5620 DUBLINSHIRE DR
DUBLIN, OHIO 43017
BID SET
May 1, 2026
DRAWING INDEX
DWG NO. SHEET TITLE
COVER SHEET
P-001 GENERAL INFORMATION - PLUMBING
P-101 PARTIAL FIRST FLOOR PLAN - PLUMBING - DEMOLITION
P-102 PARTIAL FIRST FLOOR PLAN - PLUMBING
PREPARED BY
E-001 GENERAL INFORMATION - ELECTRICAL
E-101 PARTIAL FIRST FLOOR PLAN - ELECTRICAL - DEMOLITION
E-102 PARTIAL FIRST FLOOR PLAN - ELECTRICAL
PERMITS AND REGULATIONS GENERAL NOTE(S) TO CONTRACTOR:
THE CONTRACTOR SHALL OBTAIN ALL RELATED PERMITS REQUIRED BY LAWS, ORDINANCES, RULES, REGULATIONS,
AND PUBLIC AUTHORITY HAVING JURISDICTION (CITY OF COLUMBUS). THE CONTRACTOR SHALL OBTAIN Advanced Engineering Consultants
CERTIFICATES OF INSPECTIONS AS REQUIRED BY THE PERMIT DOCUMENTS AND SHALL SUBMIT SAME TO THE A/E. THE
1405 Dublin Road Tel: (614) 486-4778
CONTRACTOR SHALL PAY ALL FEES, CHARGES, AND EXPENSES IN CONNECTION THEREWITH. THE CONTRACTOR SHALL
FURNISH TO THE OWNER A CERTIFICATE OF FINAL INSPECTION FROM THE PROPER AUTHORITY PRIOR TO FINAL Columbus, Ohio 43215 Fax: (614) 486-4082
PAYMENT. OBTAIN AND PAY FOR EASEMENTS REQUIRED TO BRING TEMPORARY UTILITIES TO THE SITE, WHERE THE
OWNER'S EASEMENT CANNOT BE UTILIZED FOR THAT PURPOSE.
THE CONTRACTOR SHALL NOT ALLOW OR CAUSE ANY OF THE WORK TO BE COVERED UP OR ENCLOSED UNTIL THE A/E
OR OWNER HAS BEEN NOTIFIED AND GIVEN REASONABLE OPPORTUNITY (5 WORKING DAYS) TO REVIEW THE WORK.
WHEN REQUIRED BY LAW OR REGULATIONS, THE GOVERNMENTAL AGENCY HAVING JURISDICTION FOR INSPECTIONS
SHALL BE GIVEN REASONABLE NOTICE AND OPPORTUNITY TO INSPECT THE WORK. ANY WORK THAT IS ENCLOSED OR
COVERED UP BEFORE SUCH INSPECTION AND TEST SHALL BE UNCOVERED AT THE CONTRACTOR'S EXPENSE; AFTER IT
HAS BEEN INSPECTED, THE CONTRACTOR SHALL RESTORE THE WORK TO ITS ORIGINAL CONDITION AT HIS OWN
EXPENSE.

ABBREVIATIONS ABBREVIATIONS SYMBOLS LIST GENERAL NOTES: 1. PROVIDE NEW COMBINATION DOMESTIC WATER AND FIRE PROTECTION SERVICE (NOT ALL MAY BE USED) NOTE: NOT ALL ABBREVIATIONS MAY BE USED. NOTE: NOT ALL ABBREVIATIONS MAY BE USED. FOR THE BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY (A) EXISTING TO BE ABANDONED IN INCHES PIPING OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION.COORDINATE THE (D) EXISTING TO BE DEMOLISHED INV EL INVERT ELEVATION LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS EXISTING TO REMAIN (E) (E) EXISTING TO REMAIN IW INDIRECT WASTE FOR EQUIPMENT WITH OTHER TRADES. (F) FUTURE KW KILOWATT EXISTING TO BE DEMOLISHED (D) 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY (R) EXISTING TO BE RELOCATED L LAVATORY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS. FIRE PROTECTION WATER FP A COMPRESSED AIR (SHOP AIR) LB POUNDS 3. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO ABV ABOVE LF LINEAR FEET SHOW THE EXACT LOCATIONS OF COMPONENTS, NOR SHOW ALL SYSTEM DOMESTIC COLD WATER CW COMPONENTS. CONTRACTOR SHALL PROVIDE ADDITIONAL OFFSETS OR FITTINGS AE ANESTHESIA EVACUATION LG LENGTH REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER TRADES, AFF ABOVE FINISHED FLOOR LN LIQUID NITROGEN PIPING (FITTINGS, VALVES, AND MISCELLANEOUS) AND/OR TO MAINTAIN PROPER CLEARANCES. AMP AMPERE LOX LIQUID OXYGEN 4. DRAWINGS ARE NOT TO BE SCALED. DIMENSIONS SHALL GOVERN. CONTRACTOR DROP APPROX APPROXIMATE MA COMPRESSED AIR (MEDICAL GAS) SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE CONCERNING EXISTING AND NEW WORK BEFORE PROCEEDING WITH EITHER FABRICATION OR AR ARGON MAX MAXIMUM RISE INSTALLATION IN MECHANICAL AREAS WITH NUMEROUS OBSTRUCTIONS ARCH ARCHITECT MECH MECHANICAL INCLUDING DUCTWORK, EQUIPMENT AND PIPING. THIS WILL REQUIRE ON SITE AUTO AUTOMATIC MFG MANUFACTURER TEE CUTTING AND VERIFICATION. AV ACID VENT MIN MINIMUM 5. ANY INFORMATION CONFLICTS BETWEEN THE SPECIFICATIONS AND DRAWINGS CAP AVG AVERAGE MS MOP SINK SHALL BE BROUGHT TO THE ENGINEERS'S ATTENTION. THE CONTRACTOR(S) SHALL NOT PROCEED WITH ANY WORK, EXCEPT AT THEIR OWN RISK, UNTIL AW ACID WASTE MV VACUUM (MEDICAL GAS) FLOW ARROW CLARIFICATIONS OF THE CONFLICTS ARE ISSUED TO THE CONTRACTOR(S) BY THE BF BELOW FLOOR N20 NITROUS OXIDE ENGINEER. BFV BUTTERFLY VALVE N NITROGEN PUMP 6. ALL MATERIAL AND LABOR SHALL BE UNDER WARRANTY FOR ONE YEAR FROM THE BLDG BUILDING N/A NOT APPLICABLE DATE OF FINAL ACCEPTANCE BY THE OWNER. ANY NEW DEVICES OR EQUIPMENT GLOBE VALVE FOUND FAULTY SHALL BE REPLACED AS PART OF THE WARRANTY. BOP BOTTOM OF PIPE NC NORMALLY CLOSED BT BATHTUB NIC NOT IN CONTRACT PLUG VALVE 7. A SET OF APPROVED DRAWINGS SHALL BE MAINTAINED ON SITE AND ALL FIELD CHANGES SHALL BE RED LINED ON THE DRAWINGS. CONTRACTOR SHALL CAP CAPACITY NO NORMALLY OPEN PREPARE "AS-BUILT" DRAWINGS IN ELECTRONIC (PDF) FORMAT, REFLECTING SOLENOID VALVE S CFH CUBIC FEET PER HOUR NO. NUMBER ACCURATE FIELD CONDITIONS. CFM CUBIC FEET PER MINUTE NPW NON-POTABLE WATER GAS PRESSURE REGULATOR 8. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE CONN CONNECTION OR CONNECT NTS NOT TO SCALE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE CONT CONTINUATION O OXYGEN PRESSURE REDUCING VALVE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER. CS CLINIC SINK OFCI OWNER FURNISHED CONTRACTOR INSTALLED OUTSIDE STEM & YOKE VALVE CU FT CUBIC FEET OS&Y OUTSIDE STEM AND YOKE VALVE 9. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER THAN THE PIPE DIAMETER OF THE PENETRATING PIPE. CU IN CUBIC INCH PD PUMPED DISCHARGE REDUCED PRESSURE BACKFLOW PREVENTER D DRAIN PLBG PLUMBING 10. DUCTWORK, PIPING, MECHANICAL EQUIPMENT AND CEILINGS SHALL NOT BE USED AS LADDERS, SCAFFOLDING OR WORK PLATFORMS. DEPT DEPARTMENT PPM PARTS PER MILLION BUTTERFLY VALVE DIA DIAMETER PR FUEL POLISH RETURN 11. NO STRUCTURAL MEMBERS SHALL BE CUT, DRILLED, OR BURNED WITHOUT THE BALL VALVE KNOWLEDGE AND WRITTEN APPROVAL OF THE OWNER. DI DEIONIZED WATER PRESS PRESSURE DN DOWN PRV PRESSURE REDUCING VALVE CHECK VALVE 12. EQUIPMENT, MATERIALS, INSTALLATION WORKMANSHIP, EXAMINATION AND DW DISTILLED WATER PS FUEL POLISH SUPPLY TESTING SHALL BE IN ACCORDANCE WITH CURRENT PLUMBING CODE. INSTALL PIPING STRAIGHT AND TRUE TO BEAR EVENLY ON HANGARS AND SUPPORTS. PIPE DWG DRAWING PSI POUNDS PER SQUARE INCH BALANCE VALVE SHALL NOT INTERFERE WITH OTHER EQUIPMENT AND CONSTRUCTION. E EMERGENCY FIXTURE PSIG PSI GAUGE STRAINER 13. CONTRACTOR SHALL BE RESPONSIBLE FOR AVOIDING ALL CONFLICTS WITH EL ELEVATION RCP RECIRCULATING PUMP LIGHTING FIXTURES, DIFFUSERS, GRILLES, DUCTS, STRUCTURAL MEMBERS, EQUIP EQUIPMENT RD ROOF DRAIN UNION MECHANICAL EQUIPMENT AND PIPES. EWC ELECTRIC WATER COOLER RPBP REDUCED PRESSURE BACKFLOW PREVENTER 14. NO FABRICATION OR INSTALLATION IS ALLOWED WITHOUT APPROVED SHOP TEMPERATURE & PRESSURE RELIEF VALVE EXH EXHAUST RPM REVOLUTIONS PER MINUTE DRAWING SUBMITTALS. EXP EXPANSION RO REVERSE OSMOSIS WATER METER M 15. CONTRACTOR SHALL SUBMIT SYSTEM CATALOG PRODUCT DATA SHEETS OF ALL EXIST EXISTING S SINK COMPONENTS PROPOSED FOR USE PRIOR TO INSTALLATION FOR APPROVAL. SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL. degreesF DEGREES FAHRENHEIT SEC SECOND PIPE SLEEVE FD FLOOR DRAIN SH SHOWER 16. ALL MATERIALS AND EQUIPMENT SHALL BE NEW. WATER HAMMER ARRESTOR A FIN FL EL FINISHED FLOOR ELEVATION SHT SHEET 17. PIPING SHALL NOT SHARE SUPPORTS WITH OTHER BUILDING SYSTEMS. IN FOD FUEL OIL DISCHARGE SPEC SPECIFICATION PRESSURE/TEMPERATURE TEST PLUG MECHANICAL AREAS, PIPING SHALL NOT BE ATTACHED TO THE DUCT WORK. FOF FUEL OIL FILL SRD SECONDARY ROOF DRAIN STANCHIONS SHALL BE USED WHERE PIPING IS UNABLE TO BE HUNG FROM A ABOVE. FOG FUEL OIL GAUGE LINE STSTL STAINLESS STEEL AQUASTAT FOO FUEL OIL OVER FLOW LINE STD STANDARD 18. PIPING IN AREAS WITH FINISHED CEILINGS SHALL BE INSTALLED ABOVE FINISHED WALL HYDRANT OR HOSE BIBB CEILINGS. FOR FUEL OIL RETURN STR STRAINER FOS FUEL OIL SUPPLY SW SOFT POTABLE WATER CO 19. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL PIPING. CLEANOUT FOV FUEL OIL TANK VENT TE TOP ELEVATION 20. PIPING SHALL NOT BE INSTALLED PASSING THROUGH ELECTRICAL ROOMS OR CO F.S. FLOW SWITCH TEMP TEMPERATURE CLEANOUT AT FLOOR OR AT GRADE OVER ELECTRICAL PANELS / EQUIPMENT WHICH SERVES OTHER AREAS. COORDINATE THE LOCATION OF ALL PIPING WITH ELECTRICAL EQUIPMENT AND FT FOOT OR FEET TMV THERMOSTATIC MIXING VALVE FLOOR OR AREA DRAIN OTHER TRADES AND ADJUST AS NECESSARY. GA GAUGE TOP TOP OF PIPE GAL GALLONS TS TAMPER SWITCH ROOF DRAIN 21. MAKE REASONABLE AND NECESSARY MODIFICATIONS IN LAYOUTS AND COMPONENTS NEEDED TO PREVENT CONFLICTS WITH WORK OF OTHER TRADES GPD GALLONS PER DAY TWS TEMPERED WATER SUPPLY AND TO COORDINATE IN ACCORDANCE WITH SPECIFICATIONS. GPH GALLONS PER HOUR TYP TYPICAL THERMOMETER 22. MAINTAIN MAXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT GPM GALLONS PER MINUTE UNO UNLESS NOTED OTHERWISE TO THE UNDERSIDE OF DECK AS POSSIBLE. AL EXPOSED PIPING SHALL BE H HYDROGEN UR URINAL APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES. PRESSURE GAUGE WITH STOPCOCK HD HEAD V VOLT/VENT 23. CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, FEES, AND PERMITS FOR A HE HELIUM VB VACUUM BREAKER COMPLETE INSTALLATION. CONTRACTOR SHALL COMPLY WITH ALL GENERAL NOTATIONS CONDITIONS LISTED ON THE ARCHITECTURAL DOCUMENTS. HGT HEIGHT VTR VENT THRU ROOF CONNECT TO EXISTING HP HORSEPOWER W WATER HVAC HEATING, VENTILATING, AND AIR CONDITIONING WC WATER CLOSET BEGINNING AND/OR END OF DEMOLITION HZ HERTZ WF WASH FOUNTAIN Advanced Engineering Consultants 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL 04/02/26 SUBMITTAL: BID SET GENERAL INFORMATION P-001 PLUMBING SCALE: NONE DSN: P. MELCHER DRN: P. MELCHER CHK: J. HILL DATE: MAY 1, 2026
Advanced Engineering Consultants 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082
REV NUMBER REV DESCRIPTION REV DATE
DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL
04/02/26
GENERAL INFORMATION PLUMBING SUBMITTAL: BID SET P-001
SCALE: NONE
DSN: P. MELCHER DRN: P. MELCHER CHK: J. HILL DATE: MAY 1, 2026
ABBREVIATIONS
NOTE: NOT ALL ABBREVIATIONS MAY BE USED.
(A) EXISTING TO BE ABANDONED
(D) EXISTING TO BE DEMOLISHED
(E) EXISTING TO REMAIN
(F) FUTURE
(R) EXISTING TO BE RELOCATED
A COMPRESSED AIR (SHOP AIR)
ABV ABOVE
AE ANESTHESIA EVACUATION
AFF ABOVE FINISHED FLOOR
AMP AMPERE
APPROX APPROXIMATE
AR ARGON
ARCH ARCHITECT
AUTO AUTOMATIC
AV ACID VENT
AVG AVERAGE
AW ACID WASTE
BF BELOW FLOOR
BFV BUTTERFLY VALVE
BLDG BUILDING
BOP BOTTOM OF PIPE
BT BATHTUB
CAP CAPACITY
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CONN CONNECTION OR CONNECT
CONT CONTINUATION
CS CLINIC SINK
CU FT CUBIC FEET
CU IN CUBIC INCH
D DRAIN
DEPT DEPARTMENT
DIA DIAMETER
DI DEIONIZED WATER
DN DOWN
DW DISTILLED WATER
DWG DRAWING
E EMERGENCY FIXTURE
EL ELEVATION
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXP EXPANSION
EXIST EXISTING
degreesF DEGREES FAHRENHEIT
FD FLOOR DRAIN
FIN FL EL FINISHED FLOOR ELEVATION
FOD FUEL OIL DISCHARGE
FOF FUEL OIL FILL
FOG FUEL OIL GAUGE LINE
FOO FUEL OIL OVER FLOW LINE
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL TANK VENT
F.S. FLOW SWITCH
FT FOOT OR FEET
GA GAUGE
GAL GALLONS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H HYDROGEN
HD HEAD
HE HELIUM
HGT HEIGHT
HP HORSEPOWER
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HZ HERTZ
ABBREVIATIONS
NOTE: NOT ALL ABBREVIATIONS MAY BE USED.
IN INCHES
INV EL INVERT ELEVATION
IW INDIRECT WASTE
KW KILOWATT
L LAVATORY
LB POUNDS
LF LINEAR FEET
LG LENGTH
LN LIQUID NITROGEN
LOX LIQUID OXYGEN
MA COMPRESSED AIR (MEDICAL GAS)
MAX MAXIMUM
MECH MECHANICAL
MFG MANUFACTURER
MIN MINIMUM
MS MOP SINK
MV VACUUM (MEDICAL GAS)
N20 NITROUS OXIDE
N NITROGEN
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO. NUMBER
NPW NON-POTABLE WATER
NTS NOT TO SCALE
O OXYGEN
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OS&Y OUTSIDE STEM AND YOKE VALVE
PD PUMPED DISCHARGE
PLBG PLUMBING
PPM PARTS PER MILLION
PR FUEL POLISH RETURN
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PS FUEL POLISH SUPPLY
PSI POUNDS PER SQUARE INCH
PSIG PSI GAUGE
RCP RECIRCULATING PUMP
RD ROOF DRAIN
RPBP REDUCED PRESSURE BACKFLOW PREVENTER
RPM REVOLUTIONS PER MINUTE
RO REVERSE OSMOSIS WATER
S SINK
SEC SECOND
SH SHOWER
SHT SHEET
SPEC SPECIFICATION
SRD SECONDARY ROOF DRAIN
STSTL STAINLESS STEEL
STD STANDARD
STR STRAINER
SW SOFT POTABLE WATER
TE TOP ELEVATION
TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TOP TOP OF PIPE
TS TAMPER SWITCH
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UR URINAL
V VOLT/VENT
VB VACUUM BREAKER
VTR VENT THRU ROOF
W WATER
WC WATER CLOSET
WF WASH FOUNTAIN
SYMBOLS LIST (NOT ALL MAY BE USED)
PIPING
EXISTING TO REMAIN (E) EXISTING TO BE DEMOLISHED (D) FIRE PROTECTION WATER FP DOMESTIC COLD WATER CW
PIPING (FITTINGS, VALVES, AND MISCELLANEOUS)
DROP RISE TEE CAP FLOW ARROW PUMP GLOBE VALVE PLUG VALVE SOLENOID VALVE S GAS PRESSURE REGULATOR PRESSURE REDUCING VALVE OUTSIDE STEM & YOKE VALVE REDUCED PRESSURE BACKFLOW PREVENTER BUTTERFLY VALVE BALL VALVE CHECK VALVE BALANCE VALVE STRAINER UNION TEMPERATURE & PRESSURE RELIEF VALVE METER M PIPE SLEEVE WATER HAMMER ARRESTOR A PRESSURE/TEMPERATURE TEST PLUG A AQUASTAT WALL HYDRANT OR HOSE BIBB CO CLEANOUT CO CLEANOUT AT FLOOR OR AT GRADE FLOOR OR AREA DRAIN ROOF DRAIN THERMOMETER PRESSURE GAUGE WITH STOPCOCK
NOTATIONS
CONNECT TO EXISTING BEGINNING AND/OR END OF DEMOLITION

Advanced Engineering Consultants
1405 Dublin Road Tel: (614) 486-4778
Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE
DCSD 2026 PLUMBING IMPROVEMENTS PROJECT
WYANDOT ELEMENTARY SCHOOL
04/02/26
SUBMITTAL: BID SET
SCALE:
DSN: DRN: CHK: DATE: MAY 1, 2026
sdleiF.neK:tidE
tsaL
\todnayW\steehS
DAC\DAC\sedargpU
gnibmulP
dna
CAVH
SCD
700-200-52\jorp
5202\:Z:noitacoL
eliF
MP
95:21
6202/03/4:etaD
ABBREVIATIONS ABBREVIATIONS SYMBOLS LIST GENERAL NOTES:
1. PROVIDE NEW COMBINATION DOMESTIC WATER AND FIRE PROTECTION SERVICE
(NOT ALL MAY BE USED)
NOTE: NOT ALL ABBREVIATIONS MAY BE USED. NOTE: NOT ALL ABBREVIATIONS MAY BE USED.
FOR THE BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY
(A) EXISTING TO BE ABANDONED IN INCHES PIPING OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE
REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION.COORDINATE THE
(D) EXISTING TO BE DEMOLISHED INV EL INVERT ELEVATION LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS
EXISTING TO REMAIN (E)
(E) EXISTING TO REMAIN IW INDIRECT WASTE FOR EQUIPMENT WITH OTHER TRADES.
(F) FUTURE KW KILOWATT EXISTING TO BE DEMOLISHED (D) 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY
(R) EXISTING TO BE RELOCATED L LAVATORY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS.
FIRE PROTECTION WATER FP
A COMPRESSED AIR (SHOP AIR) LB POUNDS
3. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO
ABV ABOVE LF LINEAR FEET SHOW THE EXACT LOCATIONS OF COMPONENTS, NOR SHOW ALL SYSTEM
DOMESTIC COLD WATER CW
COMPONENTS. CONTRACTOR SHALL PROVIDE ADDITIONAL OFFSETS OR FITTINGS
AE ANESTHESIA EVACUATION LG LENGTH
REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER TRADES,
AFF ABOVE FINISHED FLOOR LN LIQUID NITROGEN PIPING (FITTINGS, VALVES, AND MISCELLANEOUS) AND/OR TO MAINTAIN PROPER CLEARANCES.
AMP AMPERE LOX LIQUID OXYGEN
4. DRAWINGS ARE NOT TO BE SCALED. DIMENSIONS SHALL GOVERN. CONTRACTOR
DROP
APPROX APPROXIMATE MA COMPRESSED AIR (MEDICAL GAS) SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE CONCERNING
EXISTING AND NEW WORK BEFORE PROCEEDING WITH EITHER FABRICATION OR
AR ARGON MAX MAXIMUM
RISE INSTALLATION IN MECHANICAL AREAS WITH NUMEROUS OBSTRUCTIONS
ARCH ARCHITECT MECH MECHANICAL
INCLUDING DUCTWORK, EQUIPMENT AND PIPING. THIS WILL REQUIRE ON SITE
AUTO AUTOMATIC MFG MANUFACTURER TEE CUTTING AND VERIFICATION.
AV ACID VENT MIN MINIMUM
5. ANY INFORMATION CONFLICTS BETWEEN THE SPECIFICATIONS AND DRAWINGS
CAP
AVG AVERAGE MS MOP SINK SHALL BE BROUGHT TO THE ENGINEERS'S ATTENTION. THE CONTRACTOR(S)
SHALL NOT PROCEED WITH ANY WORK, EXCEPT AT THEIR OWN RISK, UNTIL
AW ACID WASTE MV VACUUM (MEDICAL GAS)
FLOW ARROW CLARIFICATIONS OF THE CONFLICTS ARE ISSUED TO THE CONTRACTOR(S) BY THE
BF BELOW FLOOR N20 NITROUS OXIDE ENGINEER.
BFV BUTTERFLY VALVE N NITROGEN PUMP
6. ALL MATERIAL AND LABOR SHALL BE UNDER WARRANTY FOR ONE YEAR FROM THE
BLDG BUILDING N/A NOT APPLICABLE DATE OF FINAL ACCEPTANCE BY THE OWNER. ANY NEW DEVICES OR EQUIPMENT
GLOBE VALVE
FOUND FAULTY SHALL BE REPLACED AS PART OF THE WARRANTY.
BOP BOTTOM OF PIPE NC NORMALLY CLOSED
BT BATHTUB NIC NOT IN CONTRACT PLUG VALVE 7. A SET OF APPROVED DRAWINGS SHALL BE MAINTAINED ON SITE AND ALL FIELD
CHANGES SHALL BE RED LINED ON THE DRAWINGS. CONTRACTOR SHALL
CAP CAPACITY NO NORMALLY OPEN
PREPARE "AS-BUILT" DRAWINGS IN ELECTRONIC (PDF) FORMAT, REFLECTING
SOLENOID VALVE S
CFH CUBIC FEET PER HOUR NO. NUMBER
ACCURATE FIELD CONDITIONS.
CFM CUBIC FEET PER MINUTE NPW NON-POTABLE WATER
GAS PRESSURE REGULATOR 8. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE
CONN CONNECTION OR CONNECT NTS NOT TO SCALE
PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE
CONT CONTINUATION O OXYGEN PRESSURE REDUCING VALVE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO
THE RATING OF THE PENETRATED BARRIER.
CS CLINIC SINK OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OUTSIDE STEM & YOKE VALVE
CU FT CUBIC FEET OS&Y OUTSIDE STEM AND YOKE VALVE 9. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER
THAN THE PIPE DIAMETER OF THE PENETRATING PIPE.
CU IN CUBIC INCH PD PUMPED DISCHARGE
REDUCED PRESSURE BACKFLOW PREVENTER
D DRAIN PLBG PLUMBING 10. DUCTWORK, PIPING, MECHANICAL EQUIPMENT AND CEILINGS SHALL NOT BE USED
AS LADDERS, SCAFFOLDING OR WORK PLATFORMS.
DEPT DEPARTMENT PPM PARTS PER MILLION BUTTERFLY VALVE
DIA DIAMETER PR FUEL POLISH RETURN 11. NO STRUCTURAL MEMBERS SHALL BE CUT, DRILLED, OR BURNED WITHOUT THE
BALL VALVE
KNOWLEDGE AND WRITTEN APPROVAL OF THE OWNER.
DI DEIONIZED WATER PRESS PRESSURE
DN DOWN PRV PRESSURE REDUCING VALVE
CHECK VALVE 12. EQUIPMENT, MATERIALS, INSTALLATION WORKMANSHIP, EXAMINATION AND
DW DISTILLED WATER PS FUEL POLISH SUPPLY TESTING SHALL BE IN ACCORDANCE WITH CURRENT PLUMBING CODE. INSTALL
PIPING STRAIGHT AND TRUE TO BEAR EVENLY ON HANGARS AND SUPPORTS. PIPE
DWG DRAWING PSI POUNDS PER SQUARE INCH BALANCE VALVE
SHALL NOT INTERFERE WITH OTHER EQUIPMENT AND CONSTRUCTION.
E EMERGENCY FIXTURE PSIG PSI GAUGE
STRAINER 13. CONTRACTOR SHALL BE RESPONSIBLE FOR AVOIDING ALL CONFLICTS WITH
EL ELEVATION RCP RECIRCULATING PUMP
LIGHTING FIXTURES, DIFFUSERS, GRILLES, DUCTS, STRUCTURAL MEMBERS,
EQUIP EQUIPMENT RD ROOF DRAIN UNION MECHANICAL EQUIPMENT AND PIPES.
EWC ELECTRIC WATER COOLER RPBP REDUCED PRESSURE BACKFLOW PREVENTER
14. NO FABRICATION OR INSTALLATION IS ALLOWED WITHOUT APPROVED SHOP
TEMPERATURE & PRESSURE RELIEF VALVE
EXH EXHAUST RPM REVOLUTIONS PER MINUTE DRAWING SUBMITTALS.
EXP EXPANSION RO REVERSE OSMOSIS WATER
METER M 15. CONTRACTOR SHALL SUBMIT SYSTEM CATALOG PRODUCT DATA SHEETS OF ALL
EXIST EXISTING S SINK COMPONENTS PROPOSED FOR USE PRIOR TO INSTALLATION FOR APPROVAL.
SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL.
degreesF DEGREES FAHRENHEIT SEC SECOND PIPE SLEEVE
FD FLOOR DRAIN SH SHOWER 16. ALL MATERIALS AND EQUIPMENT SHALL BE NEW.
WATER HAMMER ARRESTOR A
FIN FL EL FINISHED FLOOR ELEVATION SHT SHEET
17. PIPING SHALL NOT SHARE SUPPORTS WITH OTHER BUILDING SYSTEMS. IN
FOD FUEL OIL DISCHARGE SPEC SPECIFICATION
PRESSURE/TEMPERATURE TEST PLUG MECHANICAL AREAS, PIPING SHALL NOT BE ATTACHED TO THE DUCT WORK.
FOF FUEL OIL FILL SRD SECONDARY ROOF DRAIN STANCHIONS SHALL BE USED WHERE PIPING IS UNABLE TO BE HUNG FROM
A
ABOVE.
FOG FUEL OIL GAUGE LINE STSTL STAINLESS STEEL AQUASTAT
FOO FUEL OIL OVER FLOW LINE STD STANDARD 18. PIPING IN AREAS WITH FINISHED CEILINGS SHALL BE INSTALLED ABOVE FINISHED
WALL HYDRANT OR HOSE BIBB CEILINGS.
FOR FUEL OIL RETURN STR STRAINER
FOS FUEL OIL SUPPLY SW SOFT POTABLE WATER CO 19. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL PIPING.
CLEANOUT
FOV FUEL OIL TANK VENT TE TOP ELEVATION
20. PIPING SHALL NOT BE INSTALLED PASSING THROUGH ELECTRICAL ROOMS OR
CO
F.S. FLOW SWITCH TEMP TEMPERATURE CLEANOUT AT FLOOR OR AT GRADE OVER ELECTRICAL PANELS / EQUIPMENT WHICH SERVES OTHER AREAS.
COORDINATE THE LOCATION OF ALL PIPING WITH ELECTRICAL EQUIPMENT AND
FT FOOT OR FEET TMV THERMOSTATIC MIXING VALVE
FLOOR OR AREA DRAIN OTHER TRADES AND ADJUST AS NECESSARY.
GA GAUGE TOP TOP OF PIPE
GAL GALLONS TS TAMPER SWITCH ROOF DRAIN 21. MAKE REASONABLE AND NECESSARY MODIFICATIONS IN LAYOUTS AND
COMPONENTS NEEDED TO PREVENT CONFLICTS WITH WORK OF OTHER TRADES
GPD GALLONS PER DAY TWS TEMPERED WATER SUPPLY
AND TO COORDINATE IN ACCORDANCE WITH SPECIFICATIONS.
GPH GALLONS PER HOUR TYP TYPICAL
THERMOMETER
22. MAINTAIN MAXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT
GPM GALLONS PER MINUTE UNO UNLESS NOTED OTHERWISE
TO THE UNDERSIDE OF DECK AS POSSIBLE. AL EXPOSED PIPING SHALL BE
H HYDROGEN UR URINAL APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES.
PRESSURE GAUGE WITH STOPCOCK
HD HEAD V VOLT/VENT
23. CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, FEES, AND PERMITS FOR A
HE HELIUM VB VACUUM BREAKER COMPLETE INSTALLATION. CONTRACTOR SHALL COMPLY WITH ALL GENERAL
NOTATIONS
CONDITIONS LISTED ON THE ARCHITECTURAL DOCUMENTS.
HGT HEIGHT VTR VENT THRU ROOF
CONNECT TO EXISTING
HP HORSEPOWER W WATER
HVAC HEATING, VENTILATING, AND AIR CONDITIONING WC WATER CLOSET
BEGINNING AND/OR END OF DEMOLITION
HZ HERTZ WF WASH FOUNTAIN
GENERAL INFORMATION P-001
PLUMBING
NONE
P. MELCHER P. MELCHER J. HILL

GENERAL NOTES: A. DEMOLISH COMPLETE EXISTING COMBINATION WATER SERVICE BACK TO CONNECTIONS AT SLAB. DEMO CW AND SPRINKLER PIPING TO OVERHEAD. PREPARE FOR CONNECTION TO NEW WATER SERVICE PIPING. CODED NOTES: 1. 6" COMBINATION WATER SERVICE FROM SITE. DEMOLISH BACK TO FLANGE AT FLOOR. 2. EXISTING WATER METER TO BE REMOVED AND RETAINED FOR RE-INSTALLATION AS PART OF NEW WORK. 103 106 3. DEMOLISH 3" CW PIPING BACK TO OVERHEAD. PREPARE FOR CONNECTION TO NEW WORK. 4. EXISTING CHECK VALVES TO BE DEMOLISHED. 5. DEMOLISH 4" SPRINKLER PIPING BACK TO OVERHEAD. PREPARE FOR CONNECTION TO NEW WORK. 123T 122 6. 6" LINE TO SITE FIRE HYDRANT. DEMOLISH BACK TO FLANGE AT FLOOR. 126 7. EXISTING BAS PANEL TO BE RELOCATED. REFER TO ELECTRICAL DRAWINGS. 8. EXISTING BAS PANEL TO REMAIN. 124 8 7 5 4 127 121M 6 3 125 2 M 128 129 1 EXTERIOR MECHANICAL COURTYARD PARTIAL FIRST FLOOR PLAN - PLUMBING - DEMOLITION 1 N 1/8"=1'-0" 0 4' 8' 16' KEY PLAN SCALE: NTS Advanced Engineering Consultants 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL 04/02/26 SUBMITTAL: BID SET PARTIAL FIRST FLOOR PLAN P-101 PLUMBING - DEMOLITION SCALE: 1/8" = 1'-0" DSN: P. MELCHER DRN: P. MELCHER CHK: J. HILL DATE: MAY 1, 2026
Advanced Engineering Consultants 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082
REV NUMBER REV DESCRIPTION REV DATE
DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL
04/02/26
PARTIAL FIRST FLOOR PLAN PLUMBING - DEMOLITION SUBMITTAL: BID SET P-101
SCALE: 1/8" = 1'-0"
DSN: P. MELCHER DRN: P. MELCHER CHK: J. HILL DATE: MAY 1, 2026

GENERAL NOTES:
A. DEMOLISH COMPLETE EXISTING COMBINATION WATER
SERVICE BACK TO CONNECTIONS AT SLAB. DEMO CW AND
SPRINKLER PIPING TO OVERHEAD. PREPARE FOR
CONNECTION TO NEW WATER SERVICE PIPING.
CODED NOTES:
1. 6" COMBINATION WATER SERVICE FROM SITE. DEMOLISH BACK TO FLANGE AT
FLOOR.
2. EXISTING WATER METER TO BE REMOVED AND RETAINED FOR
RE-INSTALLATION AS PART OF NEW WORK.
103 106
3. DEMOLISH 3" CW PIPING BACK TO OVERHEAD. PREPARE FOR CONNECTION TO
NEW WORK.
4. EXISTING CHECK VALVES TO BE DEMOLISHED.
5. DEMOLISH 4" SPRINKLER PIPING BACK TO OVERHEAD. PREPARE FOR
CONNECTION TO NEW WORK.
123T
122 6. 6" LINE TO SITE FIRE HYDRANT. DEMOLISH BACK TO FLANGE AT FLOOR.
126
7. EXISTING BAS PANEL TO BE RELOCATED. REFER TO ELECTRICAL DRAWINGS.
8. EXISTING BAS PANEL TO REMAIN.
124
127
121M
125
128 129
PARTIAL FIRST FLOOR PLAN - PLUMBING - DEMOLITION
1 N
1/8"=1'-0" 0 4' 8' 16'
KEY PLAN
SCALE: NTS
M
8
7
5
4
6
3
2
1
EXTERIOR MECHANICAL COURTYARD
Advanced Engineering Consultants
1405 Dublin Road Tel: (614) 486-4778
Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE
DCSD 2026 PLUMBING IMPROVEMENTS PROJECT
WYANDOT ELEMENTARY SCHOOL
04/02/26
SUBMITTAL: BID SET
SCALE:
DSN: DRN: CHK: DATE: MAY 1, 2026
sdleiF.neK:tidE
tsaL
\todnayW\steehS
DAC\DAC\sedargpU
gnibmulP
dna
CAVH
SCD
700-200-52\jorp
5202\:Z:noitacoL
eliF
MP
95:21
6202/03/4:etaD
PARTIAL FIRST FLOOR PLAN P-101
PLUMBING - DEMOLITION
1/8" = 1'-0"
P. MELCHER P. MELCHER J. HILL

GENERAL NOTES: A. PROVIDE NEW COMBINATION WATER SERVICE ADHERING TO CITY COLUMBUS DIVISION OF WATER REQUIREMENTS. B. DIMENSIONS SHOWN AROUND AROUND SERVICE ARE REQUIRED BY CITY OF COLUMBUS. CODED NOTES: 1. RECONNECT TO EXISTING 6" WATER FROM SITE AT FLOOR FLANGE. 2. RECONNECT TO EXISTING 6" WATER LINE SERVING SITE HYDRANT AT FLOOR FLANGE. 103 106 3. CONNECT NEW 3" DOMESTIC WATER AND 4" SPRINKLER TO EXISTING UTILITIES OF SAME TYPE OVERHEAD. 4. NEW 3" ASSE 1013 DOMESTIC WATER BACKFLOW DEVICE AND 6" ASSE 1048 FIRE PROTECTION BACKFLOW DEVICE STACKED AT THIS APPROXIMATE LOCATION. 5. EXISTING BAS PANEL. ENSURE NO NEW PIPING IS ROUTED THROUGH CLEARANCE SPACE DIRECTLY IN FRONT OF PANEL. 123T 122 126 124 5 3 4 127 2 121M 2'-0" 125 3" ASSE 1013 BACKFLOW PREVENTER SIMILAR TO NEW 24V ALARM. 2'-0" WATTS MODEL 4000SS. COORDINATE WITH FIRE ZINC COATED ALL ALARM CONTRACTOR. 128 129 THREAD (TYP) RE-INSTALL RETAINED F.S. WATER METER. WIRE TO NEW 4" SPRINKLER BUILDING REMOTE READER. "0-'2 1 RISER VALVE. OS&Y VALVE (TYP.) T.S. T.S. T.S. T.S. 2" DRAIN THROUGH WALL. EXTEND 2" DRAIN TO T.S. T.S. PROVIDE BIRD SCREEN BUILDING EXTERIOR. AT TERMINATION POINT. N.C. FLOOR SUPPORTS (TYP.) (E)6" WATER FROM SITE. 6" ASSE 1048 BACKFLOW PREVENTER SIMILAR TO (E)6" WATER TO HYDRANT. WATTS MODEL 3000SS. NOTES: 1. BUILDING SPRINKLER SYSTEM DOES NOT CONTAIN ANY CHEMICAL SYSTEMS 2. ENTIRE SERVICE SHALL BE PER CITY OF COLUMBUS DIVISION OF WATER DETAILS: L-6317A, L-6317C, L-6317D, L-9002A, L-9002B, AND L-9002F. 3. EXISTING FIRE DEPARTMENT CONNECTION IS DOWNSTREAM OF WATER SERVICE. DETAIL - COMBINATION WATER SERVICE ENTRANCE 2 NTS PARTIAL FIRST FLOOR PLAN - PLUMBING 1 N 1/8"=1'-0" 0 4' 8' 16' KEY PLAN SCALE: NTS Advanced Engineering Consultants 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL 04/02/26 SUBMITTAL: BID SET PARTIAL FIRST FLOOR PLAN P-102 PLUMBING SCALE: 1/8" = 1'-0" DSN: P. MELCHER DRN: P. MELCHER CHK: J. HILL DATE: MAY 1, 2026
SUBMITTAL: BID SET P-102
SCALE: 1/8" = 1'-0"
DRN: P. MELCHER CHK: J. HILL DATE: MAY 1, 2026
.S. T.S
REV NUMBER REV DESCRIPTION REV DATE

GENERAL NOTES:
A. PROVIDE NEW COMBINATION WATER SERVICE ADHERING
TO CITY COLUMBUS DIVISION OF WATER REQUIREMENTS.
B. DIMENSIONS SHOWN AROUND AROUND SERVICE ARE
REQUIRED BY CITY OF COLUMBUS.
CODED NOTES:
1. RECONNECT TO EXISTING 6" WATER FROM SITE AT FLOOR FLANGE.
2. RECONNECT TO EXISTING 6" WATER LINE SERVING SITE HYDRANT AT FLOOR
FLANGE.
103 106 3. CONNECT NEW 3" DOMESTIC WATER AND 4" SPRINKLER TO EXISTING UTILITIES
OF SAME TYPE OVERHEAD.
4. NEW 3" ASSE 1013 DOMESTIC WATER BACKFLOW DEVICE AND 6" ASSE 1048 FIRE
PROTECTION BACKFLOW DEVICE STACKED AT THIS APPROXIMATE LOCATION.
5. EXISTING BAS PANEL. ENSURE NO NEW PIPING IS ROUTED THROUGH
CLEARANCE SPACE DIRECTLY IN FRONT OF PANEL.
123T
122
126
124
127
121M
125
2'-0"
128 129
DETAIL - COMBINATION WATER SERVICE ENTRANCE
2
NTS
PARTIAL FIRST FLOOR PLAN - PLUMBING
1 N
1/8"=1'-0" 0 4' 8' 16'
KEY PLAN
SCALE: NTS
"0-'2
5
3
4
2
2'-0"
3" ASSE 1013 BACKFLOW
PREVENTER SIMILAR TO NEW 24V ALARM.
WATTS MODEL 4000SS. COORDINATE WITH FIRE
ZINC COATED ALL ALARM CONTRACTOR.
THREAD (TYP)
RE-INSTALL RETAINED
F.S. WATER METER. WIRE TO
NEW 4" SPRINKLER BUILDING REMOTE READER.
1 RISER VALVE.
OS&Y VALVE (TYP.)
T.S. T.S. T.S. T.S.
2" DRAIN THROUGH WALL.
EXTEND 2" DRAIN TO T.S.
T.S. PROVIDE BIRD SCREEN
BUILDING EXTERIOR.
AT TERMINATION POINT.
N.C.
FLOOR
SUPPORTS (TYP.)
(E)6" WATER FROM SITE.
6" ASSE 1048 BACKFLOW
PREVENTER SIMILAR TO (E)6" WATER TO HYDRANT.
WATTS MODEL 3000SS.
NOTES:
1. BUILDING SPRINKLER SYSTEM DOES NOT CONTAIN ANY
CHEMICAL SYSTEMS
2. ENTIRE SERVICE SHALL BE PER CITY OF COLUMBUS
DIVISION OF WATER DETAILS: L-6317A, L-6317C, L-6317D,
L-9002A, L-9002B, AND L-9002F.
3. EXISTING FIRE DEPARTMENT CONNECTION IS
DOWNSTREAM OF WATER SERVICE.
Advanced Engineering Consultants
1405 Dublin Road Tel: (614) 486-4778
Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE
DCSD 2026 PLUMBING IMPROVEMENTS PROJECT
WYANDOT ELEMENTARY SCHOOL
04/02/26
SUBMITTAL: BID SET
SCALE:
DSN: DRN: CHK: DATE: MAY 1, 2026
sdleiF.neK:tidE
tsaL
\todnayW\steehS
DAC\DAC\sedargpU
gnibmulP
dna
CAVH
SCD
700-200-52\jorp
5202\:Z:noitacoL
eliF
MP
95:21
6202/03/4:etaD
PARTIAL FIRST FLOOR PLAN P-102
PLUMBING
1/8" = 1'-0"
P. MELCHER P. MELCHER J. HILL

GENERAL NOTES: ABBREVIATIONS LINE TYPE LEGEND POWER SYMBOLS FIRE ALARM SYMBOLS A. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIAL, NOTE: NOT ALL ABBREVIATIONS MAY BE USED. NOTE: NOT ALL SYMBOLS MAY BE USED. NOTE: NOT ALL SYMBOLS MAY BE USED. EQUIPMENT, AND CONTRACTOR SERVICES NECESSARY TO COMPLETE (A) EXISTING TO BE ABANDONED EXISTING TO REMAIN X 20A DUPLEX RECEPTACLE WITH COVER PLATE: MANUAL PULL STATION WITH PROTECTIVE COVER INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITH APPLICABLE F Y X=TYPE, Y"=NON-STANDARD MOUNTING HEIGHT, (48" TO HANDLE OF DEVICE); NC = NO COVER (D) EXISTING TO BE DEMOLISHED CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL AND Z Z=SPECIAL DESIGNATION, (18" AFF TYPICAL) (E) EXISTING TO REMAIN EXISTING TO BE REMOVED COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL APPURTENANCES FOR A H HEAT DETECTOR DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT COMPLETE SYSTEM. (F) FUTURE X WITH COVER PLATE: X=TYPE, Y"=NON-STANDARD NEW WORK Y (R) EXISTING TO BE RELOCATED MTG HEIGHT, Z=SPECIAL DESIGNATION, (18" AFF Z TYPICAL) S SMOKE DETECTOR B. ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND A AMPERE LOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY AC ALTERNATING CURRENT OR AIR CONDITIONER F,C FLOOR OR CEILING MOUNTED DUPLEX ACCEPTED CODES AND STANDARDS. THE ELECTRICAL CONTRACTOR WILL BEAR RECEPTACLE: F=FLOOR, C=CEILING CO COMBINATION SMOKE/CARBON MONOXIDE ALL COSTS ARISING IN CORRECTING ANY NONCOMPLIANCE WITH THE AFF ABOVE FINISHED FLOOR S DETECTOR REQUIREMENTS OF APPLICABLE CODES. AFG ABOVE FINISHED GRADE DUPLEX RECEPTACLE: ABOVE COUNTER (48" AFF AIC AMPS INTERRUPTING CAPACITY TYPICAL) MC MULTI-CRITERIA DETECTOR (SMOKE, HEAT AND S C. MINIMUM CONDUCTORS SIZE SHALL BE #12 AWG AND OTHER CONDUCTOR SIZES CARBON MONOXIDE) ANNC ANNUNCIATOR DOUBLE-DUPLEX RECEPTACLE WITH SINGLE MUST COMPLY WITH TABLE 310.16 OF NATIONAL ELECTRICAL CODE (NFPA 70, AWG AMERICAN WIRE GAUGE COVER PLATE LATEST EDITION). BPS BOLTED PRESSURE SWITCH SIMPLEX RECEPTACLE WITH COVER PLATE S DUCT MOUNTED SMOKE DETECTOR D. CONTRACTOR SHALL PROVIDE A NEAT AND ORDERLY PROFESSIONAL C CONDUIT WEATHER RESISTANT DUPLEX RECEPTACLE, WP INSTALLATION. ALL REQUIREMENTS OF THE LATEST APPROVED ADDITION OF CB CIRCUIT BREAKER GROUND FAULT CIRCUIT INTERRUPTING WITH IN-USE SPEAKER; C = CEILING MOUNTED COVER S C (80" AFF TO BOTTOM OF DEVICE) NFPA 70E SHALL BE FOLLOWED. CCTV CLOSED CIRCUIT TELEVISION WALL MOUNTED SPECIAL RECEPTACLE: REFER TO CKT CIRCUIT SPEAKER WITH STROBE; C = CEILING MOUNTED E. ALL WALL AND FLOOR PENETRATIONS ARE TO BE SLEEVED AND FIRE STOPPED PLANS FOR ADDITIONAL INFORMATION C (80" AFF TO BOTTOM OF DEVICE) THE SAME DAY THAT THE PENETRATION IS MADE. FIRE STOPS ARE TO BE THE CM CONSTRUCTION MANAGER FLOOR OR CEILING MOUNTED SPECIAL SAME RATING AS THE EXISTING STRUCTURE BEING PENETRATED, MINIMUM OF 2 DC DIRECT CURRENT F,C HORN; C = CEILING MOUNTED RECEPTACLE: F=FLOOR, C=CEILING REFER TO C F (80" AFF TO BOTTOM OF DEVICE) HOURS. DP DISTRIBUTION PANELBOARD PLANS FOR ADDITIONAL INFORMATION DTT DOUBLE TWIN TUBE SURFACE MOUNTED RACEWAY C HORN WITH STROBE; C = CEILING MOUNTED F. CONTRACTOR TO USE EXTREME CARE DURING DEMOLITION TO MINIMIZE DAMAGE (80" AFF TO BOTTOM OF DEVICE) EB ELECTRONIC BALLAST X STANDARD DISCONNECT SWITCH: X=DISCONNECT TO SURROUNDING AREAS. PATCH, REPAIR, PREP, AND PAINT ANY DAMAGED Y SIZE, Y=NUMBER OF POLES WALLS, CEILINGS, OR FLOOR FROM REMOVED ITEMS RESULTING FROM THIS EC ELECTRICAL CONTRACTOR Z CEILING MOUNTED STROBE WORK. MATCH ADJACENT SURFACES, REPLACE CEILING TILE, AND HARDWARE EM EMERGENCY X STANDARD FUSED DISCONNECT SWITCH: WITH NEW MATERIAL OF THE SAME TYPE AS EXISTING. ALL CUTTING, PATCHING, EMT ELECTRICAL METAL TUBING Y X=DISCONNECT SIZE, Y=FUSE SIZE, Z=NUMBER OF WALL MOUNTED STROBE Z POLES (80" AFF TO BOTTOM OF DEVICE) AND REPAIR WORK SHOULD BE DONE BY APPROPRIATE TRADE. EWC ELECTRIC WATER COOLER X MOTOR STARTER: X=STARTER SIZE, Y=NUMBER OF FA FIRE ALARM Y G. PROVIDE STAINLESS STEEL BLANK COVER PLATES FOR CLOSURE OF RECESSED POLES F FIRE BELL Z BOXES IN MECHANICAL SPACES AND BRICK OR BLOCK WALLS. RECESSED BOXES FLA FULL LOAD AMPS X COMBINATION MOTOR STARTER/DISCONNECT WF ADDRESSABLE MODULE FOR WATER FLOW SWITCH IN DRYWALL SHALL BE PATCHED, FINISHED, AND PAINTED. COORDINATE PAINT G GROUND Y SWITCH: X=STARTER SIZE, Y=FUSE SIZE, Z=NUMBER COLORS WITH DCSD. GC GENERAL TRADES CONTRACTOR Z OF POLES T ADDRESSABLE MODULE FOR TAMPER SWITCH GFCI GROUND FAULT CIRCUIT INTERRUPTER M MOTOR (BY OTHERS): PROVIDE POWER AS PV ADDRESSABLE MODULE FOR PIV H. ALL FIRE ALARM ADDRESSABLE DEVICES SHALL BE PERMANENTLY AND VISIBLY INDICATED GEN GENERATOR TAGGED (E.G. P-TOUCH LABEL) WITH FIRE ALARM CIRCUIT AND ADDRESS. TAG ADDRESSABLE INPUT-OUTPUT MODULE (FOR M UTILITY METER M ADDRESS OF ANY CONCEALED FA (E.G. ADDRESSABLE MODULES, DUCT HOA HAND-OFF-AUTOMATIC EQUIPMENT AS NOTED) DETECTORS, ETC.) ON WALL OR CEILING GRID. FRACTIONAL HORSEPOWER MANUAL MOTOR HP HORSEPOWER STARTER DH MAGNETIC DOOR HOLDER - WALL MOUNTED HPC HIGH PRESSURE CONTACT SWITCH F DH MAGNETIC DOOR HOLDER - FLOOR MOUNTED I. SPLICING OF FIRE ALARM WIRING BY MEANS OF WIRE NUTS IS PROHIBITED. ALL J JUNCTION BOX HZ HERTZ WIRING SHALL ORIGINATE FROM PANELS, TERMINAL CABINETS/BOXES, OR REMOTE INDICATOR STATION AND TEST SWITCH FOR IG ISOLATED GROUND TRANSFORMER RI DUCT SMOKE DETECTOR (WALL MOUNTED, 60" AFF) DEVICES. IMC INTERMEDIATE METAL CONDUIT HANDHOLE/POLE BOX: SEE DETAILS FOR RI C REMOTE INDICATOR STATION AND TEST SWITCH FOR J. UNLESS NOTED OTHERWISE, FIRE ALARM ADDRESSABLE MODULES SHOWN ON INCD INCANDESCENT HH DUCT SMOKE DETECTOR (CEILING MOUNTED) ADDITIONAL INFORMATION PLANS ARE TO SERVE ADJACENT DEVICES/EQUIPMENT. KVA KILOVOLT AMPERE R ADDRESSABLE RELAY MODULE CP CONTROL PANEL KW KILOWATT KX KNOX BOX K. CONTRACTOR TO PROVIDE ALL BUILDING FIRE WATCHES (I.E. DURING OUTAGE OF SPD SURGE PROTECTIVE DEVICE LTG LIGHTING OR LIGHT FACP, NOTIFICATION OR DETECTION) AS NECESSARY. COMPLY WITH FIRE WATCH FAAP FIRE ALARM ANNUNCIATOR PANEL REQUIREMENTS OF THE AHJ (WASHINGTON TOWNSHIP FIRE DEPARTMENT). LRA LOCKED ROTOR AMPS PANELBOARD FACP FIRE ALARM CONTROL PANEL MCA MINIMUM CIRCUIT AMPACITY NAC NOTIFICATION APPLIANCE CIRCUIT PANEL MCB MAIN CIRCUIT BREAKER ATS AUTOMATIC TRANSFER SWITCH MCC MOTOR CONTROL CENTER VFD VARIABLE FREQUENCY DRIVE (BY DIVISION 23) MDP MAIN DISTRIBUTION PANEL PUSH BUTTON MLO MAIN LUGS ONLY POWER POLE MOCP MAXIMUM OVERCURRENT PROTECTION CORD REEL MSB MAIN SWITCHBOARD GROUND ROD MH METAL HALIDE X PT POKE THROUGH SERVICE FITTING: X=TYPE MTS MANUAL TRANSFER SWITCH NAC NOTIFICATION APPLIANCE CIRCUIT NC NORMALLY CLOSED NO NORMALLY OPEN NF NON-FUSED OCC OCCUPANCY PA PUBLIC ADDRESS PB PULL BOX OR PUSH BUTTON PVC POLYVINYL CHLORIDE (PLASTIC PIPE) PWR POWER RECPT RECEPTACLE STP SHIELDED, TWISTED PAIR TC TIME CLOCK TRT TRIPLE TUBE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UTP UNSHIELDED, TWISTED PAIR V VOLT W WATT WAP WIRELESS ACCESS POINT WH WATTHOUR WP WEATHERPROOF, NEMA 3R UNO XFMR TRANSFORMER Z IMPEDANCE Advanced Engineering Consultants PHASE 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL 04/02/26 SUBMITTAL: BID SET GENERAL INFORMATION E-001 ELECTRICAL SCALE: NONE DSN: G.LIM DRN: G.LIM CHK: N.ALBAUGH DATE: MAY 1, 2026
Advanced Engineering Consultants 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082
REV NUMBER REV DESCRIPTION REV DATE
DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL
04/02/26
GENERAL INFORMATION ELECTRICAL SUBMITTAL: BID SET
E-001
SCALE: NONE
DSN: G.LIM DRN: G.LIM CHK: N.ALBAUGH DATE: MAY 1, 2026
ABBREVIATIONS
NOTE: NOT ALL ABBREVIATIONS MAY BE USED.
(A) EXISTING TO BE ABANDONED
(D) EXISTING TO BE DEMOLISHED
(E) EXISTING TO REMAIN
(F) FUTURE
(R) EXISTING TO BE RELOCATED
A AMPERE
AC ALTERNATING CURRENT OR AIR CONDITIONER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPS INTERRUPTING CAPACITY
ANNC ANNUNCIATOR
AWG AMERICAN WIRE GAUGE
BPS BOLTED PRESSURE SWITCH
C CONDUIT
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CM CONSTRUCTION MANAGER
DC DIRECT CURRENT
DP DISTRIBUTION PANELBOARD
DTT DOUBLE TWIN TUBE
EB ELECTRONIC BALLAST
EC ELECTRICAL CONTRACTOR
EM EMERGENCY
EMT ELECTRICAL METAL TUBING
EWC ELECTRIC WATER COOLER
FA FIRE ALARM
FLA FULL LOAD AMPS
G GROUND
GC GENERAL TRADES CONTRACTOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GEN GENERATOR
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HPC HIGH PRESSURE CONTACT SWITCH
HZ HERTZ
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCD INCANDESCENT
KVA KILOVOLT AMPERE
KW KILOWATT
LTG LIGHTING OR LIGHT
LRA LOCKED ROTOR AMPS
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MLO MAIN LUGS ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MSB MAIN SWITCHBOARD
MH METAL HALIDE
MTS MANUAL TRANSFER SWITCH
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NORMALLY CLOSED
NO NORMALLY OPEN
NF NON-FUSED
OCC OCCUPANCY
PA PUBLIC ADDRESS
PB PULL BOX OR PUSH BUTTON
PVC POLYVINYL CHLORIDE (PLASTIC PIPE)
PWR POWER
RECPT RECEPTACLE
STP SHIELDED, TWISTED PAIR
TC TIME CLOCK
TRT TRIPLE TUBE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UTP UNSHIELDED, TWISTED PAIR
V VOLT
W WATT
WAP WIRELESS ACCESS POINT
WH WATTHOUR
WP WEATHERPROOF, NEMA 3R UNO
XFMR TRANSFORMER
Z IMPEDANCE
PHASE
LINE TYPE LEGEND
EXISTING TO REMAIN EXISTING TO BE REMOVED NEW WORK
POWER SYMBOLS
NOTE: NOT ALL SYMBOLS MAY BE USED.
X Y Z 20A DUPLEX RECEPTACLE WITH COVER PLATE: X=TYPE, Y"=NON-STANDARD MOUNTING HEIGHT, Z=SPECIAL DESIGNATION, (18" AFF TYPICAL)
X Y Z DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT WITH COVER PLATE: X=TYPE, Y"=NON-STANDARD MTG HEIGHT, Z=SPECIAL DESIGNATION, (18" AFF TYPICAL)
F,C FLOOR OR CEILING MOUNTED DUPLEX RECEPTACLE: F=FLOOR, C=CEILING
DUPLEX RECEPTACLE: ABOVE COUNTER (48" AFF TYPICAL)
DOUBLE-DUPLEX RECEPTACLE WITH SINGLE COVER PLATE
SIMPLEX RECEPTACLE WITH COVER PLATE
WP WEATHER RESISTANT DUPLEX RECEPTACLE, GROUND FAULT CIRCUIT INTERRUPTING WITH IN-USE COVER
WALL MOUNTED SPECIAL RECEPTACLE: REFER TO PLANS FOR ADDITIONAL INFORMATION
F,C FLOOR OR CEILING MOUNTED SPECIAL RECEPTACLE: F=FLOOR, C=CEILING REFER TO PLANS FOR ADDITIONAL INFORMATION
SURFACE MOUNTED RACEWAY
X Y Z STANDARD DISCONNECT SWITCH: X=DISCONNECT SIZE, Y=NUMBER OF POLES
X Y Z STANDARD FUSED DISCONNECT SWITCH: X=DISCONNECT SIZE, Y=FUSE SIZE, Z=NUMBER OF POLES
X Y Z MOTOR STARTER: X=STARTER SIZE, Y=NUMBER OF POLES
X Y Z COMBINATION MOTOR STARTER/DISCONNECT SWITCH: X=STARTER SIZE, Y=FUSE SIZE, Z=NUMBER OF POLES
M MOTOR (BY OTHERS): PROVIDE POWER AS INDICATED
M UTILITY METER
FRACTIONAL HORSEPOWER MANUAL MOTOR STARTER
J JUNCTION BOX
TRANSFORMER
HH HANDHOLE/POLE BOX: SEE DETAILS FOR ADDITIONAL INFORMATION
CP CONTROL PANEL
SPD SURGE PROTECTIVE DEVICE
PANELBOARD
ATS AUTOMATIC TRANSFER SWITCH
VFD VARIABLE FREQUENCY DRIVE (BY DIVISION 23)
PUSH BUTTON
POWER POLE
CORD REEL
GROUND ROD
X PT POKE THROUGH SERVICE FITTING: X=TYPE
FIRE ALARM SYMBOLS
NOTE: NOT ALL SYMBOLS MAY BE USED.
F MANUAL PULL STATION WITH PROTECTIVE COVER (48" TO HANDLE OF DEVICE); NC = NO COVER
H HEAT DETECTOR
S SMOKE DETECTOR
CO S COMBINATION SMOKE/CARBON MONOXIDE DETECTOR
MC S MULTI-CRITERIA DETECTOR (SMOKE, HEAT AND CARBON MONOXIDE)
S DUCT MOUNTED SMOKE DETECTOR
C S SPEAKER; C = CEILING MOUNTED (80" AFF TO BOTTOM OF DEVICE)
C SPEAKER WITH STROBE; C = CEILING MOUNTED (80" AFF TO BOTTOM OF DEVICE)
C F HORN; C = CEILING MOUNTED (80" AFF TO BOTTOM OF DEVICE)
C HORN WITH STROBE; C = CEILING MOUNTED (80" AFF TO BOTTOM OF DEVICE)
CEILING MOUNTED STROBE
WALL MOUNTED STROBE (80" AFF TO BOTTOM OF DEVICE)
F FIRE BELL
WF ADDRESSABLE MODULE FOR WATER FLOW SWITCH
T ADDRESSABLE MODULE FOR TAMPER SWITCH
PV ADDRESSABLE MODULE FOR PIV
M ADDRESSABLE INPUT-OUTPUT MODULE (FOR EQUIPMENT AS NOTED)
DH MAGNETIC DOOR HOLDER - WALL MOUNTED
F DH MAGNETIC DOOR HOLDER - FLOOR MOUNTED
RI REMOTE INDICATOR STATION AND TEST SWITCH FOR DUCT SMOKE DETECTOR (WALL MOUNTED, 60" AFF)
C RI REMOTE INDICATOR STATION AND TEST SWITCH FOR DUCT SMOKE DETECTOR (CEILING MOUNTED)
R ADDRESSABLE RELAY MODULE
KX KNOX BOX
F AAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
NAC NOTIFICATION APPLIANCE CIRCUIT PANEL

GENERAL NOTES:
ABBREVIATIONS LINE TYPE LEGEND POWER SYMBOLS FIRE ALARM SYMBOLS
A. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIAL,
NOTE: NOT ALL ABBREVIATIONS MAY BE USED. NOTE: NOT ALL SYMBOLS MAY BE USED. NOTE: NOT ALL SYMBOLS MAY BE USED.
EQUIPMENT, AND CONTRACTOR SERVICES NECESSARY TO COMPLETE
(A) EXISTING TO BE ABANDONED EXISTING TO REMAIN X 20A DUPLEX RECEPTACLE WITH COVER PLATE: MANUAL PULL STATION WITH PROTECTIVE COVER INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITH APPLICABLE
F
Y X=TYPE, Y"=NON-STANDARD MOUNTING HEIGHT, (48" TO HANDLE OF DEVICE); NC = NO COVER
(D) EXISTING TO BE DEMOLISHED CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL AND
Z Z=SPECIAL DESIGNATION, (18" AFF TYPICAL)
(E) EXISTING TO REMAIN EXISTING TO BE REMOVED COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL APPURTENANCES FOR A
H HEAT DETECTOR
DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT COMPLETE SYSTEM.
(F) FUTURE X
WITH COVER PLATE: X=TYPE, Y"=NON-STANDARD
NEW WORK Y
(R) EXISTING TO BE RELOCATED MTG HEIGHT, Z=SPECIAL DESIGNATION, (18" AFF
Z TYPICAL) S SMOKE DETECTOR B. ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND
A AMPERE LOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY
AC ALTERNATING CURRENT OR AIR CONDITIONER F,C FLOOR OR CEILING MOUNTED DUPLEX ACCEPTED CODES AND STANDARDS. THE ELECTRICAL CONTRACTOR WILL BEAR
RECEPTACLE: F=FLOOR, C=CEILING CO COMBINATION SMOKE/CARBON MONOXIDE ALL COSTS ARISING IN CORRECTING ANY NONCOMPLIANCE WITH THE
AFF ABOVE FINISHED FLOOR S
DETECTOR
REQUIREMENTS OF APPLICABLE CODES.
AFG ABOVE FINISHED GRADE DUPLEX RECEPTACLE: ABOVE COUNTER (48" AFF
AIC AMPS INTERRUPTING CAPACITY TYPICAL) MC MULTI-CRITERIA DETECTOR (SMOKE, HEAT AND
S C. MINIMUM CONDUCTORS SIZE SHALL BE #12 AWG AND OTHER CONDUCTOR SIZES
CARBON MONOXIDE)
ANNC ANNUNCIATOR DOUBLE-DUPLEX RECEPTACLE WITH SINGLE MUST COMPLY WITH TABLE 310.16 OF NATIONAL ELECTRICAL CODE (NFPA 70,
AWG AMERICAN WIRE GAUGE COVER PLATE LATEST EDITION).
BPS BOLTED PRESSURE SWITCH SIMPLEX RECEPTACLE WITH COVER PLATE S DUCT MOUNTED SMOKE DETECTOR
D. CONTRACTOR SHALL PROVIDE A NEAT AND ORDERLY PROFESSIONAL
C CONDUIT WEATHER RESISTANT DUPLEX RECEPTACLE,
WP INSTALLATION. ALL REQUIREMENTS OF THE LATEST APPROVED ADDITION OF
CB CIRCUIT BREAKER GROUND FAULT CIRCUIT INTERRUPTING WITH IN-USE SPEAKER; C = CEILING MOUNTED
COVER S C (80" AFF TO BOTTOM OF DEVICE) NFPA 70E SHALL BE FOLLOWED.
CCTV CLOSED CIRCUIT TELEVISION
WALL MOUNTED SPECIAL RECEPTACLE: REFER TO
CKT CIRCUIT SPEAKER WITH STROBE; C = CEILING MOUNTED E. ALL WALL AND FLOOR PENETRATIONS ARE TO BE SLEEVED AND FIRE STOPPED
PLANS FOR ADDITIONAL INFORMATION C
(80" AFF TO BOTTOM OF DEVICE)
THE SAME DAY THAT THE PENETRATION IS MADE. FIRE STOPS ARE TO BE THE
CM CONSTRUCTION MANAGER
FLOOR OR CEILING MOUNTED SPECIAL SAME RATING AS THE EXISTING STRUCTURE BEING PENETRATED, MINIMUM OF 2
DC DIRECT CURRENT F,C HORN; C = CEILING MOUNTED
RECEPTACLE: F=FLOOR, C=CEILING REFER TO C
F (80" AFF TO BOTTOM OF DEVICE) HOURS.
DP DISTRIBUTION PANELBOARD PLANS FOR ADDITIONAL INFORMATION
DTT DOUBLE TWIN TUBE SURFACE MOUNTED RACEWAY C HORN WITH STROBE; C = CEILING MOUNTED F. CONTRACTOR TO USE EXTREME CARE DURING DEMOLITION TO MINIMIZE DAMAGE
(80" AFF TO BOTTOM OF DEVICE)
EB ELECTRONIC BALLAST X STANDARD DISCONNECT SWITCH: X=DISCONNECT TO SURROUNDING AREAS. PATCH, REPAIR, PREP, AND PAINT ANY DAMAGED
Y
SIZE, Y=NUMBER OF POLES WALLS, CEILINGS, OR FLOOR FROM REMOVED ITEMS RESULTING FROM THIS
EC ELECTRICAL CONTRACTOR Z CEILING MOUNTED STROBE
WORK. MATCH ADJACENT SURFACES, REPLACE CEILING TILE, AND HARDWARE
EM EMERGENCY X STANDARD FUSED DISCONNECT SWITCH:
WITH NEW MATERIAL OF THE SAME TYPE AS EXISTING. ALL CUTTING, PATCHING,
EMT ELECTRICAL METAL TUBING Y X=DISCONNECT SIZE, Y=FUSE SIZE, Z=NUMBER OF WALL MOUNTED STROBE
Z POLES (80" AFF TO BOTTOM OF DEVICE) AND REPAIR WORK SHOULD BE DONE BY APPROPRIATE TRADE.
EWC ELECTRIC WATER COOLER
X
MOTOR STARTER: X=STARTER SIZE, Y=NUMBER OF
FA FIRE ALARM Y G. PROVIDE STAINLESS STEEL BLANK COVER PLATES FOR CLOSURE OF RECESSED
POLES F FIRE BELL
Z BOXES IN MECHANICAL SPACES AND BRICK OR BLOCK WALLS. RECESSED BOXES
FLA FULL LOAD AMPS
X COMBINATION MOTOR STARTER/DISCONNECT WF ADDRESSABLE MODULE FOR WATER FLOW SWITCH IN DRYWALL SHALL BE PATCHED, FINISHED, AND PAINTED. COORDINATE PAINT
G GROUND
Y SWITCH: X=STARTER SIZE, Y=FUSE SIZE, Z=NUMBER COLORS WITH DCSD.
GC GENERAL TRADES CONTRACTOR Z OF POLES T ADDRESSABLE MODULE FOR TAMPER SWITCH
GFCI GROUND FAULT CIRCUIT INTERRUPTER M MOTOR (BY OTHERS): PROVIDE POWER AS PV ADDRESSABLE MODULE FOR PIV H. ALL FIRE ALARM ADDRESSABLE DEVICES SHALL BE PERMANENTLY AND VISIBLY
INDICATED
GEN GENERATOR TAGGED (E.G. P-TOUCH LABEL) WITH FIRE ALARM CIRCUIT AND ADDRESS. TAG
ADDRESSABLE INPUT-OUTPUT MODULE (FOR
M UTILITY METER M ADDRESS OF ANY CONCEALED FA (E.G. ADDRESSABLE MODULES, DUCT
HOA HAND-OFF-AUTOMATIC EQUIPMENT AS NOTED)
DETECTORS, ETC.) ON WALL OR CEILING GRID.
FRACTIONAL HORSEPOWER MANUAL MOTOR
HP HORSEPOWER
STARTER DH MAGNETIC DOOR HOLDER - WALL MOUNTED
HPC HIGH PRESSURE CONTACT SWITCH F
DH MAGNETIC DOOR HOLDER - FLOOR MOUNTED I. SPLICING OF FIRE ALARM WIRING BY MEANS OF WIRE NUTS IS PROHIBITED. ALL
J JUNCTION BOX
HZ HERTZ WIRING SHALL ORIGINATE FROM PANELS, TERMINAL CABINETS/BOXES, OR
REMOTE INDICATOR STATION AND TEST SWITCH FOR
IG ISOLATED GROUND TRANSFORMER RI DUCT SMOKE DETECTOR (WALL MOUNTED, 60" AFF) DEVICES.
IMC INTERMEDIATE METAL CONDUIT
HANDHOLE/POLE BOX: SEE DETAILS FOR RI C REMOTE INDICATOR STATION AND TEST SWITCH FOR J. UNLESS NOTED OTHERWISE, FIRE ALARM ADDRESSABLE MODULES SHOWN ON
INCD INCANDESCENT HH DUCT SMOKE DETECTOR (CEILING MOUNTED)
ADDITIONAL INFORMATION PLANS ARE TO SERVE ADJACENT DEVICES/EQUIPMENT.
KVA KILOVOLT AMPERE
R ADDRESSABLE RELAY MODULE
CP CONTROL PANEL
KW KILOWATT KX KNOX BOX K. CONTRACTOR TO PROVIDE ALL BUILDING FIRE WATCHES (I.E. DURING OUTAGE OF
SPD SURGE PROTECTIVE DEVICE
LTG LIGHTING OR LIGHT FACP, NOTIFICATION OR DETECTION) AS NECESSARY. COMPLY WITH FIRE WATCH
FAAP FIRE ALARM ANNUNCIATOR PANEL
REQUIREMENTS OF THE AHJ (WASHINGTON TOWNSHIP FIRE DEPARTMENT).
LRA LOCKED ROTOR AMPS PANELBOARD
FACP FIRE ALARM CONTROL PANEL
MCA MINIMUM CIRCUIT AMPACITY
NAC NOTIFICATION APPLIANCE CIRCUIT PANEL
MCB MAIN CIRCUIT BREAKER ATS AUTOMATIC TRANSFER SWITCH
MCC MOTOR CONTROL CENTER
VFD VARIABLE FREQUENCY DRIVE (BY DIVISION 23)
MDP MAIN DISTRIBUTION PANEL
PUSH BUTTON
MLO MAIN LUGS ONLY
POWER POLE
MOCP MAXIMUM OVERCURRENT PROTECTION
CORD REEL
MSB MAIN SWITCHBOARD
GROUND ROD
MH METAL HALIDE
X
PT POKE THROUGH SERVICE FITTING: X=TYPE
MTS MANUAL TRANSFER SWITCH
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NORMALLY CLOSED
NO NORMALLY OPEN
NF NON-FUSED
OCC OCCUPANCY
PA PUBLIC ADDRESS
PB PULL BOX OR PUSH BUTTON
PVC POLYVINYL CHLORIDE (PLASTIC PIPE)
PWR POWER
RECPT RECEPTACLE
STP SHIELDED, TWISTED PAIR
TC TIME CLOCK
TRT TRIPLE TUBE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UTP UNSHIELDED, TWISTED PAIR
V VOLT
W WATT
WAP WIRELESS ACCESS POINT
WH WATTHOUR
WP WEATHERPROOF, NEMA 3R UNO
XFMR TRANSFORMER
Z IMPEDANCE
Advanced Engineering Consultants
PHASE 1405 Dublin Road Tel: (614) 486-4778
Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE
DCSD 2026 PLUMBING IMPROVEMENTS PROJECT
WYANDOT ELEMENTARY SCHOOL
04/02/26
SUBMITTAL: BID SET
SCALE:
DSN: DRN: CHK: DATE: MAY 1, 2026
miL.nivaG:tidE
tsaL
\todnayW\steehS
DAC\DAC\sedargpU
gnibmulP
dna
CAVH
SCD
700-200-52\jorp
5202\:Z:noitacoL
eliF
MP
95:21
6202/03/4:etaD
GENERAL INFORMATION E-001
ELECTRICAL
NONE
G.LIM G.LIM N.ALBAUGH

CODED NOTES: 1. DISCONNECT EXISTING FIRE ALARM MONITORING CIRCUITS SERVING TAMPER (ZONE #11) AND FLOW (ZONE #10) SWITCHES BACK TO JUNCTION BOX (SEE CODED NOTE 5). COORDINATE PHASING OF DEMOLITION WITH PLUMBING CONTRACTOR. 2. EXISTING BAS PANEL TO BE RELOCATED AND BAS CONTROLLERS WITHIN THE PANEL SHALL BE REPLACED. CONTRACTOR SHALL ENGAGE DCSD BUILDING AUTOMATION VENDOR (EMCOR, KENNY SAYERS, (614) 592-4394, kenny_sayers@emcorgroup.com) TO PERFORM THIS WORK. CONTRACTOR SHALL RELOCATE EXISTING 120V CIRCUIT TO NEW BAS PANEL LOCATION. 3. RELOCATE EXISTING RECEPTACLE CIRCUIT TO NEW RECEPTACLE ON OTHER SIDE OF LADDER. 4. DEMOLISH EXISTING FIRE PROTECTION BELL. 103 106 5. EXISTING FIRE ALARM ZONE CIRCUITS MONITORING TAMPER AND FLOW SWITCHES TO REUSED. 123T 122 126 2 3 (R) 124 (E)BAS PANEL 2 (R)BAS PANEL EXISTING BAS PANEL TO REMAIN EXISTING BAS PANEL TO BE RELOCATED J 5 127 WF 121M T 125 T 1 T 128 129 T F 4 PROPOSED BAS PANEL LOCATION PHOTO - BAS PANEL 2 NONE PARTIAL FIRST FLOOR PLAN - ELECTRICAL - DEMOLITION 1 N 1/8"=1'-0" 0 4' 8' 16' APPROXIMATE LOCATION OF FACP (SIMPLEX 4002) IN MAIN OFFICE KEY PLAN SCALE: NTS Advanced Engineering Consultants 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082 REV NUMBER REV DESCRIPTION REV DATE DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL 04/02/26 SUBMITTAL: BID SET PARTIAL FIRST FLOOR PLAN E-101 ELECTRICAL - DEMOLITION SCALE: 1/8" = 1'-0" DSN: G.LIM DRN: G.LIM CHK: N.ALBAUGH DATE: MAY 1, 2026
Advanced Engineering Consultants 1405 Dublin Road Tel: (614) 486-4778 Columbus, Ohio 43215 Fax: (614) 486-4082
REV NUMBER REV DESCRIPTION REV DATE
DCSD 2026 PLUMBING IMPROVEMENTS PROJECT WYANDOT ELEMENTARY SCHOOL
04/02/26
PARTIAL FIRST FLOOR PLAN ELECTRICAL - DEMOLITION SUBMITTAL: BID SET
E-101
SCALE: 1/8" = 1'-0"
DSN: G.LIM DRN: G.LIM CHK: N.ALBAUGH DATE: MAY 1, 2026
This page summarizes the opportunity, including an overview and a preview of the attached documents.
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Publish Date Due Date Project Number Owner Authority Project Name Primary Service Estimated

Ohio Facility Construction Commission

Due by 9/21/2026

Project Title Bid Date Completion Date Engineer Estimate Legal Advertisement Plan Holders List

Huron County Engineer

Due by 9/24/2026

Bid Number: 24-17.9C Bid Title: 24-17.9C Steel Structures Project Category: Projects Status: Open

City of Piqua

Due by 10/12/2026

Publish Date Due Date Number Owner Contractring Authority Project Name Primary Service Estimated

Ohio Facility Construction Commission

Due by 9/18/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.