DAS CC Historical Building Elevator Replacements PH1

Agency: State Government of Iowa
State: Iowa
Type of Government: State & Local
NAICS Category:
  • 236220 - Commercial and Institutional Building Construction
Posted Date: Jun 19, 2026
Due Date: Jul 9, 2026
Solicitation No: RFB944001-01
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Bid Information
Bid Number

RFB944001-01

Solicitation

DAS CC Historical Building Elevator Replacements PH1

Solicitation Type

Request for Bids

County
Description
Description

The Iowa Department of Administrative Services will be receiving bids for Freight and Passenger Elevator Replacements at the State Historical Building, 600 E. Locust St. Des Moines, Iowa 50319.
Agency Information
Number

005

Name

Administrative Services, Dept

Address 1

1305 E. Walnut St.

Address 2

City/State/Zip

Des Moines, IA 50319
Contact Information
Contact Name

Construction Procurement

Contact Title

Michael Bradbury


Contact Phone Number

(515) 823-9327

Contact Phone Extension

Contact Other Number

Contact Fax Number
Valid Dates
From

6/19/2026 10:00:00 AM

Until

7/9/2026 2:00:00 PM
Documents/Attachments

6/17/2026 8:51:03 AM

6/17/2026 8:50:47 AM

Attachment Preview

2024 INTERNATIONAL BUILDING CODE AS ADOPTED BY IOWA ADMINISTRATI VE RULE CHAPTERS 481 - 280 AND 481 - 301
2010 AMERICANS WITH DISABILITIES ACT AS ADOPTED BY IOWA ADMINIST RATIVE RULE CHAPTER 481 - 301
STATE MECHANICAL CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC HEA LTH IOWA ADMINISTRATIVE RULE CHAPTER 481 - 426
STATE PLUMBING CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC HEALT H IOWA ADMINISTRATIVE RULE CHAPTER 481 - 425
DEMO FLOOR PLANS - ELEVATOR 3 (6514)
2024 INTERNATIONAL FIRE CODE AS ADOPTED BY IOWA ADMINISTRATIVE R ULE CHAPTERS 481 - 280
DEMO FLOOR PLANS - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)
STATE ELECTRICAL CODE AS ADOPTED BY THE STATE ELECTRICAL LICENS ING BOARD IOWA ADMINISTRATIVE RULE CHAPTER 481 - 404
EXISTING CONDITIONS - ELEVATOR 3 (6514)
2024 INTERNATIONAL EXISTING BUILDING CODE AS ADOPTED BY IOWA ADM INISTRATIVE RULE CHAPTERS 481 - 301
EXISTING CONDITIONS - ELEVATOR 4 (6512)
EXISTING CONDITIONS - ELEVATOR 5 (6513)
Primary Occupancy:
The use and occupancy classification of the existing building are unchanged.
IBC Chapter 5 - General Building Heights and Areas
ENLARGED FLOOR PLANS - ELEVATOR 3 (6514)
IBC Chapter 6 - Types of Construction
ENLARGED FLOOR PLANS - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)
IBC Chaper 7 - Fire and Smoke Protection Features
New construction is limited and existing construction is not being modified.
For construction purposes, shaft is considered to be 2 HR construction.
IBC Chapter 8 - Interior Finishes
IBC Chapter 10 -Means of Egress
IBC Chapter 30 -Elevators and Conveying Systems
Fire resistance rated construction is provided at the elevator machine room.
Smoke protection at hoistway openings is not required per IBC 3006.2.
The updates to the existing building conform to the requirements of the code for new construction and are to be made
with the same materials of which the original building is constructed. The existing building is in compliance with the
mandatory fire safety requirements, the mandatory means of egress requirements, and the general safety
requirements of this chapter.
Iowa Administrative Code, Chapter 16, Division VII - Accessibility Requirements For Facilities Used by the General Public:
Iowa Administrative Code, Chapter 72 - Conveyances Installed on or After January 1, 1975
ELECTRICAL / MECHANICAL DEMO PLANS ELEVATOR 4 (6512) /
ELEVATOR 5 (6513)
NFPA - 13 Chapter 8 - Section 8.15.5
Building is fully sprinklered. In accordance with NFPA 13 - 2013, sprinkler coverage will not be provided in the new
elevator machine room nor at the bottom of the elevator pit (traction elevators). A sprinkler is not required a the top of
the hoistway due to compliance with 8.15.5.6.
ELECTRICAL / MECHANICAL PLANS ELEVATOR 4 (6512) /
ELEVATOR 5 (6513)

APPLICABLE CODE INFORMATION
THE PROJECT SHALL COMPLY WITH THE FOLLOWING CODES
2024 INTERNATIONAL BUILDING CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-280 AND 481-301
2010 AMERICANS WITH DISABILITIES ACT AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTER 481-301
STATE MECHANICAL CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-426
STATE PLUMBING CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-425
2024 INTERNATIONAL FIRE CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-280
STATE ELECTRICAL CODE AS ADOPTED BY THE STATE ELECTRICAL LICENSING BOARD IOWA ADMINISTRATIVE RULE CHAPTER 481-404
2024 INTERNATIONAL EXISTING BUILDING CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-301
2026 IOWA STATE ELEVATOR CODE
IBC Chapter 2 -Use and Occupancy Classification
Primary Occupancy:
The use and occupancy classification of the existing building are unchanged.
IBC Chapter 5 -General Building Heights and Areas
Existing building use and size to remain unchanged.
IBC Chapter 6 -Types of Construction
The type of construction for the existing building is unchanged.
IBC Chaper 7 -Fire and Smoke Protection Features
New construction is limited and existing construction is not being modified.
For construction purposes, shaft is considered to be 2 HR construction.
IBC Chapter 8 -Interior Finishes
New construction is limited and matches existing interior finishes.
IBC Chapter 10 -Means of Egress
All means of egress are being maintained in the existing building.
IBC Chapter 30 -Elevators and Conveying Systems
Fire resistance rated construction is provided at the elevator machine room.
Smoke protection at hoistway openings is not required per IBC 3006.2.
IBE Chapter 34 Existing Structures:
The updates to the existing building conform to the requirements of the code for new construction and are to be made
with the same materials of which the original building is constructed. The existing building is in compliance with the
mandatory fire safety requirements, the mandatory means of egress requirements, and the general safety
requirements of this chapter.
Iowa Administrative Code, Chapter 16, Division VII -Accessibility Requirements For Facilities Used by the General Public:
Accessibility within the building will be maintained.
Iowa Administrative Code, Chapter 72 -Conveyances Installed on or After January 1, 1975
Elevator pit sump pump currently exists, and will be maintained.
NFPA-13 Chapter 8 -Section 8.15.5
Building is fully sprinklered. In accordance with NFPA 13-2013, sprinkler coverage will not be provided in the new
elevator machine room nor at the bottom of the elevator pit (traction elevators). A sprinkler is not required a the top of
the hoistway due to compliance with 8.15.5.6.
STATE OF IOWA - 9440.01 - STATE HISTORICAL
BUILDING ELEVATOR REPLACEMENTS
600 E LOCUST STREET, DES MOINES, IA 50319
100 Court Ave. Suite 100, Des Moines, IA 50309
P: 515-309-0722 F: 515-309-0725 www.opnarchitects.com
ARCHITECT CONSTRUCTION MANAGER MECHANICAL ENGINEER ELECTRICAL ENGINEER ELEVATOR CONSULTANT
OPN ARCHITECTS DCI GROUP KCL ENGINEERING KCL ENGINEERING LERCH BATES
100 COURT AVENUE 220 SE 6th STREET, SUITE 200 300 4th STREET 300 4th STREET 7625 GOLDEN TRIANGLE DRIVE, SUITE T
DES MOINES, IA 50309 DES MOINES, IA 50309 WEST DES MOINES, IA 50317 WEST DES MOINES, IA 50317 EDEN PRAIRIE, MN 55344
6202/01/60
TES
EUSSI
DIB
100GA
PROJECT LOCATION MAP SHEET INDEX
AG001 COVER SHEET
AG002 SITE LOGISTICS PLAN
AG100 OVERALL FLOOR PLANS
AD101 DEMO FLOOR PLANS -ELEVATOR 3 (6514)
PROJECT SITE AD102 DEMO FLOOR PLANS -ELEVATOR 4 (6512) / ELEVATOR 5 (6513)
AD201 EXISTING CONDITIONS -ELEVATOR 3 (6514)
AD202 EXISTING CONDITIONS -ELEVATOR 4 (6512)
AD203 EXISTING CONDITIONS -ELEVATOR 5 (6513)
A101 ENLARGED FLOOR PLANS -ELEVATOR 3 (6514)
A102 ENLARGED FLOOR PLANS -ELEVATOR 4 (6512) / ELEVATOR 5 (6513)
A103 ELEVATOR CAB DETAILS
ME000 ELECTRICAL / MECHANICAL GENERAL NOTES & SYMBOLS
ME100 ELECTRICAL / MECHANICAL OVERALL PLANS
MD101 ELECTRICAL / MECHANICAL DEMO PLANS ELEVATOR 3 (6514)
MD102 ELECTRICAL / MECHANICAL DEMO PLANS ELEVATOR 4 (6512) /
ELEVATOR 5 (6513)
ME101 ELECTRICAL / MECHANICAL PLANS ELEVATOR 3 (6514)
ME102 ELECTRICAL / MECHANICAL PLANS ELEVATOR 4 (6512) /
ELEVATOR 5 (6513)

4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
PRINTED:
1 2 3 20 21 22 23 24 25
U
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722
www.opnarchitects.com
All reports, plans, specifications, computer files, field data,
notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain
the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved
T rights, including the copyright thereto.
(C) 2025 OPN Architects, Inc.
Owner
S
Project
R
CONSTRUCTION MANAGER
DCI GROUP
220 SE 6TH STREET, SUITE 200
DES MOINES, IA 50309
ELEVATOR CONSULTANT
LERCH BATES
7625 GOLDEN TRIANGLE DRIVE,
SUITE T
EDEN PRAIRIE, MN 55344
Mechanical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Electrical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Key Plan
OPN Project No.
Sheet Issue Date
Sheet Name
Sheet Number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
6/11/2026
6:37:42
AM
CONTRACTOR TO UTILIZE STREET PARKING OR
THE CAPITOL COMPLEX GARAGE LOCATED HERE.
CONTRACTOR TO BE RESPONSIBLE FOR ALL
ASSOCIATED PARKING COSTS.
STATE OF IOWA -9440.01
109 SE 13TH STREET
DES MOINES, IA 50319
LOADING DOCK ENTRY
STATE HISTORICAL BUILDING ELEVATOR
REPLACEMENTS
DUMPSTER LOCATION AT STREET CURB -
600 E LOCUST STREET
DES MOINES, IA 50319
CONTRACTOR TO COORDINATE WITH CITY OF
DES MOINES FOR PERMITTING.
PROJECT ELEVATORS
FACILITY MAIN ENTRY
Revision Description Date
25832000
BID ISSUE SET 06/10/26
SITE LOGISTICS PLAN
AG002

ROOF
ACCESS MEN ROTAVELE RODIRROC WOMEN 3# ELEV. LOBBY STAIR #3 ELEV. #4 S TAIR HI LCP-I
EXHIBIT SPACE GALLERY LOCKER VEST. LOUNGE ELEV. #2 L MICROFILM READING ROOM ELEV. #5 ELEV. OBBY READING ROOM READING ROOM CLOSED HISTORICAL COLLECTION STACKS
LOBBY WOMEN MEN READING ROOM
V EST. P12 AD101 P12 A101
HCTAM ENIL
CHEMICAL PAINT FUMIGATION METAL STORAGE BOOTH ROOM SHOP LO R ME LLAH CKER LOCKER OOM ROOM N WOMEN RIATS ESAHC LLAH CORRIDOR MAINT. OFFICE JANITOR JANITORS STORAGE 053 LEA DISC. T2-LEA RIATS
WOOD SHOP DARK RM. STORAGE AHU L1 AHU L2 FSTSB LF MECH. MECH. RM. RM. C RODIRROC AHU L3 PROCESSING ONSERVATION LAB 054 DUPLICATION FILM CORRIDOR LG RODIRROC CAMERA RM. KRAD .MR ELEV. EQUIP.
RODIRROC GRAPHICS DEPT. AHU L4 T5-LG DISC. P1 AD101 P1 A101
PUMP RM. STAIR CORRIDOR ELEV. LOBBY ALTER STOR NATE AGE 057 ALTERNATE STORAGE
AUDITORIUM STAGE ELEV. EQUIP. STORAGE
HCTAM ENIL
BUILDING USE AT ALL TIMES.
COORDINATE ANY MAJOR DELIVERIE
OR HEAVY USE TIME WITH BUILDING.
K MEN RIATS WOMEN RODIRR ELEV. #5
OC COAT RM. LEA EA SEC1U25RITY NEWSPAPER STORAGE
EXHIBIT SPACE STAI VEST. R ORIENTATION OFFICE 130 STORAGE WORK RM. RODIRROC
HD LG LGA LCP-D LCP-GA GIFT SHOP DISPLAY STAIR HALL ARCHIVAL STORAGE
HALL PANTRY JAN. OFFICE MEN READING RM. ARCHIVAL MANUSCRIPT WOMEN PROCESSING
STAIR LOBBY LOBBY H1 AD101 H1 A101
NOITCEJORP VEST. VEST.
AUDITORIUM
VEST. P CO STORAGE ORTE PORTE CHERE COCHERE HCTAM ENIL STORAGE
STAIR #1 SUB-PANE EASJ3TA0 N2W.ALL LN L MEN ROTAVELE RODIRROC WOMEN 3# STAIR #3 ELEV. #4
RECEPTION BOARD ROOM
OPEN OFFICE LOBBY ST AIR
CONFERENCE ROOM DIRECTOR A D S IR S E IS C T T A O N R T MEETING ROOM YNOCLAB STAIR VENDING CONFERENCE WOMEN MEN ROOM WORK ROOM RECEPTION HISTORIC PRESERVATION
VEST. PANTRY
LUNCH ROOM ELEV. #5
COOLING TOWERH12 AD101 H12 A101
HCTAM ENIL

STAIR
TRANSFORMER
ROOM
ELECTRICAL ROOM
AHU L1
AHU L3 AHU
L2
AHU L4
RODIROC
LOCKER LOCKER
ROOM ROOM
CHEMICAL PAINT FUMIGATION METAL STORAGE BOOTH ROOM SHOP
MAIL ROOM
MEN WOMEN
LLAH ESAHC LLAH
ELEV. EQUIP.
CORRIDOR
CLEANING
ELEV. EQUIP.
REGISTRAR
RODIRROC
JANITOR
WOOD SHOP
WOOD STORAGE STORAGE
WOOD DARK
STORAGE RM.
WASH RM. GRAPHICS
DEPT.
PRINT RM.
PUMP
RM.
STAIR CORRIDOR L E O L B E B V. Y
ELEV.
EQUIP.
AUDITORIUM
STAGE
STORAGE
RIATS
MAINT. OFFICE
JANITORS STORAGE
MECH. MECH. RM. RM.
CONSERVATION LAB
CORRIDOR
ALTERNATE STORAGE
ALTERNATE
STORAGE
RODIRROC
ELEV. EQUIP.
RIATS
RODIRROC
PROCESSING
CAMERA RM.
DUPLICATION FILM
KRAD .MR
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A A
B B
053
LEA DISC.
T2-LEA
C C
LF
D 054 D
E E
LG
T5-LG DISC.
F F
057
G G
H H
J J
K K
HCTAM
HCTAM
ENIL
ENIL
FSTSB
ST Y O A R R A D GE EQ TE U L IP. MEN STAIR
TRASH RM.
WOMEN DOCK
VEST.
DELIVERY
EXHIBIT SPACE
STAIR
RODIRROC
AUDITORIUM
NOITCEJORP
VEST.
STORAGE
RIATS
COAT
RM.
NEWSPAPER STORAGE
SECURITY
VEST.
ORIENTATION OFFICE
WORK RM. STAIR
STORAGE
STAIR GIFT SHOP
LOBBY
LOBBY
VEST.
VEST.
PORTE PORTE COCHERE COCHERE
RODIRROC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
A
ELEV. #5 B
LEA EA
125
C
D
ELEV. 130
#2 HD LG LGA
LCP-D LCP-GA ARCHIVAL STORAGE
HALL
DISPLAY
E
OFFICE
MEN
READING
HALL RM.
ARCHIVAL
MANUSCRIPT WOMEN PROCESSING
PANTRY JAN.
F
G
H
STORAGE
J
K
HCTAM
HCTAM
ENIL
ENIL
STAIR
#1
A
B
C
D
E
F
G
H
J
K
ROTAVELE
3#
AC RO C O E F SS MEN
STAIR #3
WOMEN
ELEV.
#4
EXHIBIT
SPACE
GALLERY
ELEV. #5
RODIRROC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
ELEVATOR
#1
ELEV. LOBBY
STAIR
HI
LCP-I
READING ROOM
CLOSED
HISTORICAL
M R IC R E R A O D O O I F M N IL G M R R EA O D O I M NG CO S L T L A E C C K T S ION
LOCKER
VEST. LOUNGE
ELEV.
#2 ELEV.
LOBBY
LOBBY
READING WOMEN ROOM
MEN
VEST.
HCTAM
HCTAM
ENIL
ENIL
A A
B B
C C
D D
E E
F F
G G
H H
J J
K
STAIR #1
ROTAVELE
3#
MEN
JAN.
STAIR #3
RECEPTION BOARD WOMEN ROOM ELEV.
#4
LOBBY
OPEN
OFFICE
MEETING
ROOM
CON R F O E O R M ENCE DIRECTOR A D S IR S E IS C T T A O N R T VENDING VEST. PANTRY
L R U O N O C M H ELEV. #5
RODIRROC
YNOCLAB
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
SUB-PANEL
EAS3T0 2WALL
LN
STAIR
HISTORIC
PRESERVATION
CONFERENCE WOMEN MEN
ROOM
STAIR
WORK
ROOM
RECEPTION
COOLING
TOWER
HCTAM
HCTAM
ENIL
ENIL
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
GENERAL NOTES
1. DIMENSIONS ARE MEASURED FACE-
L2 L2 L2 L15 OF-FINISH TO FACE-OF-FINISH OR
AD102 A102 AD103 A102 ROUGH MASONRY OPENING UNLESS
NOTED OTHERWISE -TYPICAL FOR ALL
DRAWINGS.
2. FIELD VERIFY ALL DIMENSIONS AND
EXISTING CONDITIONS -TYPICAL FOR
ALL DRAWINGS.
3. IN THE EVENT OF A DISCREPANCY
BETWEEN ARCHITECTURAL AND
CONSULTANT DRAWINGS, NOTIFY
ARCHITECT IMMEDIATELY PRIOR TO
COMMENCING WORK -TYPICAL FOR
ALL DRAWINGS.
4. ALL PENETRATIONS IN FIRE RATED
FLOORS AND WALLS MUST BE SEALED
WITH APPROPRIATE FIRESTOPPING
SYSTEM.
5. PATCH AND REPAIR EXISTING FLOOR
SLABS AND WALL SURFACES
DAMAGED FROM DEMOLITION.
P1 P1
AD101 A101
P12 P12
AD101 A101
Q
P
N
M
A2 A1 A2 A15
AD102 A102 AD103 A102
L
A A
K B B
C C
J
D D
E E
H
H12 H12
AD101 A101
F F
H1 H1
AD101 A101
G
G G
H H
F
J J
E K
D
LL1155
AADD110032
6 6.5 7 8 9 10
A1 A1
C AD101 A101
A
D
MECH. LCP-C
RM. T M 7- 1 L 0 H 1 /LHB HC STAIR A.5
STAIR
LH
M101 LHB
B ELEV.
IW-1 LOBBY T2-LI
IW-2 LCP-F(ABOVE)
I I W W - - 3 4 LI HF E
B
M110
LOBBY
MECH. RM. 110
C
F
A
PRINTED:
1 2 3 20 21 22 23 24 25
U
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722
www.opnarchitects.com
All reports, plans, specifications, computer files, field data,
notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain
the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved
T rights, including the copyright thereto.
(C) 2025 OPN Architects, Inc.
Owner
S
Project
R
CONSTRUCTION MANAGER
DCI GROUP
220 SE 6TH STREET, SUITE 200
DES MOINES, IA 50309
ELEVATOR CONSULTANT
LERCH BATES
7625 GOLDEN TRIANGLE DRIVE, SUITE T
EDEN PRAIRIE, MN 55344
Mechanical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Electrical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Key Plan
OPN Project No.
Sheet Issue Date
Sheet Name
Sheet Number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
6/11/2026
6:40:38
AM
STATE OF IOWA -9440.01
109 SE 13TH STREET
DES MOINES, IA 50319
ALL ELEVATOR WORK SHOULD UTILIZE THE BASEMENT LEVEL FOR
ACCESS AND TRANSPORT OF
MATERIALS. EXISTING CONCRETE
STATE HISTORICAL BUILDING ELEVATOR
FLOORS SHOULD BE MAINTAINED AND
REPLACEMENTS
PROPER PROTECTION (INCLUDING
WHEEL PROTECTION) SHOULD BE 600 E LOCUST STREET USED TO PREVENT DAMAGE TO DES MOINES, IA 50319
FLOORS AND WALL SURFACES.
IF WORK IS REQUIRED AT OTHER
LEVELS, PROPER PROTECTION
SHOULD BE PROVIDED TO PROTECT
ALL FINISHES FROM DAMAGE.
ALL CORRIDORS ARE AVAILABLE FOR
USE BY CONTRACTORS AS REQUIRED
FOR CONSTRUCTION . CORRIDORS
CANNOT BE BLOCKED AT ANY TIME
AND MUST BE KEPT OPEN FOR
BUILDING USE AT ALL TIMES.
COORDINATE ANY MAJOR DELIVERIES
OR HEAVY USE TIME WITH BUILDING.
N OVERALL PLAN - BASEMENT N OVERALL PLAN - SECOND FLOOR
M1 M12
1/32" = 1'-0" 1/32" = 1'-0"
Revision Description Date
N OVERALL PLAN - FIRST FLOOR N OVERALL PLAN - THIRD FLOOR
D1 D12
1/32" = 1'-0" 1/32" = 1'-0"
25832000
BID ISSUE SET 06/10/26
OVERALL PLAN - MEZZANINE - WEST OVERALL PLAN - MEZZANINE - EAST
A1 A6
1/32" = 1'-0" 1/32" = 1'-0"
OVERALL PLANS
AG100

SEE ELEVATOR SPECIFICATIONS FOR
DEMO ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN.
SEE ELEVATOR SPEC FOR DEMO
ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN.
SEE ELEVATOR SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING ELEVATOR ITEMS
TO REMAIN.
EXISTING SHEET METAL ENCLOSURE
TO REMAIN. REPAIR AS REQUIRED
FROM ANY REMOVED CONDUITS TO
MAINTAIN PROPER SEPARATION
WITHIN ROOM.
REMOVE AND REPLACE EXISTING SHAFT
PROTECTION AS REQUIRED FOR NEW
INSTALL - SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
E L #
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL ANY
MODIFY EXISTING DISCONNECT - SEE
ELECTRICAL.
DEMO EXISTING DOORS AND OPENERS - SEE
ELEVATOR SPEC.
EXISTING FIXTURES TO BE REMOVED
AND REPLACED. NEW FIXTURES TO
COVER EXISTING OPENINGS
COMPLETELY.
EXISTING FIXTURES TO BE REMOVED AND
REPLACED. NEW FIXTURES TO COVER
EXISTING OPENINGS COMPLETELY.
EXISTING PAINTED FRAMES TO REMAIN
PROTECT IN PLACE. CLEAN, PATCH / FIL
ANY DAMAGE TO FRAME AND REPAINT.
DEMO EXISTING DOORS AND OPENERS
SEE ELEVATOR SPEC.
ELEV. #5
ST
SEE ELEVATOR SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING ELEVATOR ITEMS
TO REMAIN.
SEE ELEVATOR SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING ELEVATOR ITEMS
TO REMAIN.
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL ANY
DAMAGE TO FRAME AND REPAINT.
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL ANY
DAMAGE TO FRAME AND REPAINT.
DEMO EXISTING DOORS AND OPENERS - SEE
ELEVATOR SPEC.
DEMO EXISTING DOORS AND OPENERS - SEE
ELEVATOR SPEC.
EXISTING FIXTURES TO BE REMOVED AND
REPLACED. NEW FIXTURES TO COVER
EXISTING OPENINGS COMPLETELY.
EXISTING FIXTURES TO BE REMOVED AND
REPLACED. NEW FIXTURES TO COVER
EXISTING OPENINGS COMPLETELY.
DOOR REMAIN LOCKED DURING
CONSTRUCTION AND NO ACCESS ALLOWED
TO CONTRACTORS.
STA IR
SEE ELEVATOR SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING ELEVATOR ITEMS
TO REMAIN.
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL ANY
DAMAGE TO FRAME AND REPAINT.
DEMO EXISTING DOORS AND OPENERS - SEE
F(ABOV ELEVATOR SPEC.
EXISTING FIXTURES TO BE REMOVED AND
REPLACED. NEW FIXTURES TO COVER
EXISTING OPENINGS COMPLETELY.

4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
LOCKER
SEE ELEVATOR SPECIFICATIONS FOR
DEMO ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN.
SEE ELEVATOR SPEC FOR DEMO
ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN.
ELEV.
ELEV.
EXISTING SHEET METAL ENCLOSURE
LOUNGE
TO REMAIN. REPAIR AS REQUIRED
EQUIP. FROM ANY REMOVED CONDUITS TO #5
FILM MAINTAIN PROPER SEPARATION
WITHIN ROOM.
REMOVE AND REPLACE EXISTING SHAFT ELEV.
PROTECTION AS REQUIRED FOR NEW
INSTALL -SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
#2
ELEV.
MODIFY EXISTING DISCONNECT -SEE
ELECTRICAL.
LOBBY
EXISTING FIXTURES TO BE REMOVED
AND REPLACED. NEW FIXTURES TO
COVER EXISTING OPENINGS
COMPLETELY.
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL
ANY DAMAGE TO FRAME AND REPAINT.
Q
DEMO EXISTING DOORS AND OPENERS -
SEE ELEVATOR SPEC.
P
N
M
STAIR
ELEV.
#5
L
K
HALL
DISPLAY
J
H
G
F
STAIR
E
D
ELEV.
LOBBY
T2-LI
C LCP-F(ABOVE)
LI HF
B
A
PRINTED:
1 2 3 20 21 22 23 24 25
U
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722
www.opnarchitects.com
All reports, plans, specifications, computer files, field data,
notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain
the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved
T rights, including the copyright thereto.
(C) 2025 OPN Architects, Inc.
Owner
S
Project
R
CONSTRUCTION MANAGER
DCI GROUP
220 SE 6TH STREET, SUITE 200
DES MOINES, IA 50309
ELEVATOR CONSULTANT
LERCH BATES
7625 GOLDEN TRIANGLE DRIVE,
SUITE T
EDEN PRAIRIE, MN 55344
Mechanical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Electrical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Key Plan
OPN Project No.
Sheet Issue Date
Sheet Name
Sheet Number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
6/11/2026
6:40:34
AM
SEE ELEVATOR SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING ELEVATOR ITEMS
TO REMAIN.
STATE OF IOWA -9440.01
109 SE 13TH STREET
DES MOINES, IA 50319
STATE HISTORICAL BUILDING ELEVATOR
EXISTING PAINTED FRAMES TO REMAIN -
REPLACEMENTS
PROTECT IN PLACE. CLEAN, PATCH / FILL ANY
600 E LOCUST STREET
DAMAGE TO FRAME AND REPAINT.
DES MOINES, IA 50319
DEMO EXISTING DOORS AND OPENERS -SEE
ELEVATOR SPEC.
EXISTING FIXTURES TO BE REMOVED AND
REPLACED. NEW FIXTURES TO COVER
EXISTING OPENINGS COMPLETELY.
DEMO ENLARGED PLAN - BASEMENT - ELEVATOR 3 (6514) DEMO ENLARGED PLAN - SECOND FLOOR - ELEVATOR 3 (6514)
P1 P12
1/4" = 1'-0" 1/4" = 1'-0"
SEE ELEVATOR SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING ELEVATOR ITEMS SEE ELEVATOR SPECIFICATIONS FOR DEMO
TO REMAIN. ITEMS AND FOR EXISTING ELEVATOR ITEMS
TO REMAIN.
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL ANY EXISTING PAINTED FRAMES TO REMAIN -
DAMAGE TO FRAME AND REPAINT. PROTECT IN PLACE. CLEAN, PATCH / FILL ANY
DAMAGE TO FRAME AND REPAINT.
DEMO EXISTING DOORS AND OPENERS -SEE
ELEVATOR SPEC. DEMO EXISTING DOORS AND OPENERS -SEE
ELEVATOR SPEC.
EXISTING FIXTURES TO BE REMOVED AND
REPLACED. NEW FIXTURES TO COVER EXISTING FIXTURES TO BE REMOVED AND
EXISTING OPENINGS COMPLETELY. REPLACED. NEW FIXTURES TO COVER
EXISTING OPENINGS COMPLETELY.
DEMO ENLARGED PLAN - FIRST FLOOR - ELEVATOR 3 (6514) DEMO ENLARGED PLAN - THIRD FLOOR - ELEVATOR 3 (6514)
H1 H12
1/4" = 1'-0" 1/4" = 1'-0"
DOOR REMAIN LOCKED DURING
CONSTRUCTION AND NO ACCESS ALLOWED
TO CONTRACTORS.
SEE ELEVATOR SPECIFICATIONS FOR DEMO Revision Description Date
ITEMS AND FOR EXISTING ELEVATOR ITEMS
TO REMAIN.
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL ANY
DAMAGE TO FRAME AND REPAINT.
DEMO EXISTING DOORS AND OPENERS -SEE
ELEVATOR SPEC.
EXISTING FIXTURES TO BE REMOVED AND
REPLACED. NEW FIXTURES TO COVER
EXISTING OPENINGS COMPLETELY.
25832000
BID ISSUE SET 06/10/26
DEMO ENLARGED PLAN - MEZZANINE - EAST - ELEVATOR 3 (6514)
A1
1/4" = 1'-0"
ENLARGED DEMO PLANS -
ELEVATOR 3 (6514)
AD101

LCP-C 01 HC
STAIR
H/LHB LH LHB
-1 -2 -3 -4
ELEV. EQUIP. RIATS
SEE ELEVATOR SPEC FOR
DEMO ITEMS AND FOR
EXISTING ELEVATOR ITEMS TO
REMAIN.
SEE ELEVATOR SPEC FOR
DEMO ITEMS AND FOR
EXISTING ELEVATOR ITEMS TO
REMAIN.
ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN
SEE ELEVATOR SPEC FOR
DEMO ITEMS AND FOR
SEE ELEVATOR
SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN.
EXISTING FIXTURES TO BE REMOVED
AND REPLACED. NEW FIXTURES TO
COVER EXISTING OPENINGS
COMPLETELY.
EXISTING PAINTED FRAMES TO
REMAIN - PROTECT IN PLACE.
CLEAN, PATCH / FILL ANY DAMAGE
TO FRAME AND REPAINT.
AND CORNER GUARDS AT EACH JAMB
(TO +4' - 0" AFF) -
DEMO EXISTING DOORS AND OPENERS -
SEE ELEVATOR SPEC
DEMO EXISTING DOORS AND
OPENERS - SEE ELEVATOR SPEC.
DEMO EXISTING DOORS AND OPENERS -
SEE ELEVATOR SPE
EXISTING FIXTURES TO BE REMOVED
AND REPLACED. NEW FIXTURES TO
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL
ANY DAMAGE TO FRAME AND REPAINT.
EXISTING FIXTURES TO BE
REMOVED AND REPLACED. NEW
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
DEMO DISCONNECT - SEE
ELECTRICAL
ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN.
DEMO EXISTING DOORS AND
OPENERS -
EXISTING FIXTURES TO BE
REMOVED AND REPLACED. NEW
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
DEMO EXISTING DOORS AND
OPENERS - SEE ELEVATOR SPEC.
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
EXISTING PAINTED FRAMES TO
REMAIN - PROTECT IN PLACE.
CLEAN, PATCH / FILL ANY DAMAGE
TO FRAME AND REPAINT.

LOCKER
ROOM
WOMEN
LLAH
ELEV.
EQUIP.
JANITOR
RIATS
MEN
RODIRROC
RIATS
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
SEE ELEVATOR SPEC FOR
DEMO ITEMS AND FOR
EXISTING ELEVATOR ITEMS TO
REMAIN.
SEE ELEVATOR SPEC FOR
DEMO ITEMS AND FOR
EXISTING ELEVATOR ITEMS TO
REMAIN.
LCP-C
MECH.
DEMO DISCONNECT -SEE
RM. M101 HC STAIR
ELECTRICAL
SEE ELEVATOR
SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING
SEE ELEVATOR SPEC FOR T7-LH/LHB ELEVATOR ITEMS TO REMAIN.
DEMO ITEMS AND FOR
Q EXISTING ELEVATOR ITEMS TO
REMAIN.
LH
SEE ELEVATOR
SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING
P ELEVATOR ITEMS TO REMAIN.
LHB
M101
N
EXISTING FIXTURES TO BE REMOVED IW-1
EXISTING PAINTED FRAMES TO
AT EACH JAMB, REMOVE PLYWOOD AND AND REPLACED. NEW FIXTURES TO REMAIN -PROTECT IN PLACE.
PROVIDE NEW STAINLESS STEEL PLATE COVER EXISTING OPENINGS CLEAN, PATCH / FILL ANY DAMAGE
AND CORNER GUARDS AT EACH JAMB COMPLETELY. IW-2 TO FRAME AND REPAINT.
(TO +4'-0" AFF) -BOTH SIDES.
DEMO EXISTING DOORS AND OPENERS - DEMO EXISTING DOORS AND
DEMO EXISTING DOORS AND OPENERS - SEE ELEVATOR SPEC. IW-3 OPENERS -SEE ELEVATOR SPEC.
SEE ELEVATOR SPEC.
M EXISTING FIXTURES TO BE REMOVED EXISTING PAINTED FRAMES TO REMAIN - IW-4
AND REPLACED. NEW FIXTURES TO PROTECT IN PLACE. CLEAN, PATCH / FILL EXISTING FIXTURES TO BE
COVER EXISTING OPENINGS ANY DAMAGE TO FRAME AND REPAINT. REMOVED AND REPLACED. NEW
COMPLETELY. FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
DEMO DISCONNECT -SEE
ELECTRICAL
L DEMO ENLARGED PLAN - BASEMENT - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)
L2
1/4" = 1'-0"
K
J
H
G
F
E
SEE ELEVATOR
SPECIFICATIONS FOR DEMO
ELEV.
ITEMS AND FOR EXISTING
D
ELEVATOR ITEMS TO REMAIN.
#5
C
DEMO EXISTING DOORS AND EXISTING FIXTURES TO BE
OPENERS -SEE ELEVATOR SPEC. REMOVED AND REPLACED. NEW
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
EXISTING FIXTURES TO BE DEMO EXISTING DOORS AND
REMOVED AND REPLACED. NEW OPENERS -SEE ELEVATOR SPEC.
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
B EXISTING PAINTED FRAMES TO
REMAIN -PROTECT IN PLACE.
CLEAN, PATCH / FILL ANY DAMAGE
TO FRAME AND REPAINT.
A
PRINTED:
1 2 3 20 21 22 23 24 25
U
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722
www.opnarchitects.com
All reports, plans, specifications, computer files, field data,
notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain
the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved
T rights, including the copyright thereto.
(C) 2025 OPN Architects, Inc.
Owner
S
Project
R
CONSTRUCTION MANAGER
DCI GROUP
220 SE 6TH STREET, SUITE 200
DES MOINES, IA 50309
ELEVATOR CONSULTANT
LERCH BATES
7625 GOLDEN TRIANGLE DRIVE,
SUITE T
EDEN PRAIRIE, MN 55344
Mechanical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Electrical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Key Plan
OPN Project No.
Sheet Issue Date
Sheet Name
Sheet Number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
6/11/2026
6:40:34
AM
STATE OF IOWA -9440.01
109 SE 13TH STREET
DES MOINES, IA 50319
STATE HISTORICAL BUILDING ELEVATOR
REPLACEMENTS
600 E LOCUST STREET
DES MOINES, IA 50319
DEMO ENLARGED PLAN - MEZZANINE - WEST - ELEVATOR 5 (6513)
L15
1/4" = 1'-0"
Revision Description Date
25832000
BID ISSUE SET 06/10/26
DEMO ENLARGED PLAN - FIRST FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)
A2
1/4" = 1'-0"
ENLARGED DEMO PLANS -
ELEVATOR 4 (6512) /
ELEVATOR 5 (6513)
AD102

LCP-C 01 HC
STAIR
H/LHB LH LHB
-1 -2 -3 -4
ELEV. #4
DEMO EXISTING DOORS AND
OPENERS - SEE ELEVATOR SPEC
EXISTING PAINTED FRAMES TO
REMAIN - PROTECT IN PLACE.
CLEAN, PATCH / FILL ANY DAMAGE
TO FRAME AND REPAINT.
PROTECT IN PLACE. CLEAN, PATCH / FILL
ANY DAMAGE TO FRAME AND REPAINT.
EXISTING FIXTURES TO BE
REMOVED AND REPLACED. NEW
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
DEMO EXISTING DOORS AND
OPENERS - SEE ELEVATOR SPEC.
DEMO EXISTING DOORS AND OPENERS
SEE ELEVATOR SPEC.
EXISTING FIXTURES TO BE
REMOVED AND REPLACED. NEW
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
EXISTING FIXTURES TO BE REMOVED AND
REPLACED. NEW FIXTURES TO COVER
EXISTING OPENINGS COMPLETELY.
STAIR #3 ELEV. #4
ROTAVELE 3#
ELEV. #4
ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN
DEMO EXISTING DOORS AND
OPENERS - SEE ELEVATOR SPEC.
EXISTING PAINTED FRAMES TO
REMAIN - PROTECT IN PLACE.
CLEAN, PATCH / FILL ANY DAMAGE
TO FRAME AND REPAINT.
EXISTING FIXTURES TO BE
REMOVED AND REPLACED. NEW
FIXTURES TO COVER EXISTING
DEMO EXISTING DOORS AND
OPENERS - SEE ELEVATOR SPEC.
EXISTING FIXTURES TO BE
REMOVED AND REPLACED. NEW
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.

ROTAVELE
3#
STAIR
#3
ELEV.
#4
RODIRROC
ELEV.
LOBBY
ROTAVELE
3#
MEN
STAIR
#3
ELEV.
#4
LOBBY
RODIRROC
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
LCP-C
MECH.
SEE ELEVATOR RM. M101 HC STAIR SEE ELEVATOR SPECIFICATIONS FOR
SPECIFICATIONS FOR DEMO DEMO ITEMS AND FOR EXISTING
ITEMS AND FOR EXISTING ELEVATOR ITEMS TO REMAIN.
ELEVATOR ITEMS TO REMAIN.
T7-LH/LHB
Q
LH
P
LHB
M101
N IW-1
DEMO EXISTING DOORS AND EXISTING PAINTED FRAMES TO
OPENERS -SEE ELEVATOR SPEC. REMAIN -PROTECT IN PLACE. EXISTING PAINTED FRAMES TO REMAIN -
CLEAN, PATCH / FILL ANY DAMAGE PROTECT IN PLACE. CLEAN, PATCH / FILL
TO FRAME AND REPAINT. IW-2 ANY DAMAGE TO FRAME AND REPAINT.
EXISTING FIXTURES TO BE DEMO EXISTING DOORS AND
DEMO EXISTING DOORS AND OPENERS -
REMOVED AND REPLACED. NEW OPENERS -SEE ELEVATOR SPEC. IW-3
SEE ELEVATOR SPEC.
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
EXISTING FIXTURES TO BE
EXISTING FIXTURES TO BE REMOVED AND
IW-4
REMOVED AND REPLACED. NEW
M REPLACED. NEW FIXTURES TO COVER
FIXTURES TO COVER EXISTING
EXISTING OPENINGS COMPLETELY.
OPENINGS COMPLETELY.
L DEMO ENLARGED PLAN - SECOND FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)
L2
1/4" = 1'-0"
K
J
H
G
F
SEE ELEVATOR
SPECIFICATIONS FOR DEMO
ITEMS AND FOR EXISTING
ELEVATOR ITEMS TO REMAIN.
E
D
C
DEMO EXISTING DOORS AND EXISTING PAINTED FRAMES TO
OPENERS -SEE ELEVATOR SPEC. REMAIN -PROTECT IN PLACE.
CLEAN, PATCH / FILL ANY DAMAGE
TO FRAME AND REPAINT.
EXISTING FIXTURES TO BE
REMOVED AND REPLACED. NEW
DEMO EXISTING DOORS AND
FIXTURES TO COVER EXISTING
OPENERS -SEE ELEVATOR SPEC.
OPENINGS COMPLETELY.
B
EXISTING FIXTURES TO BE
REMOVED AND REPLACED. NEW
FIXTURES TO COVER EXISTING
OPENINGS COMPLETELY.
DEMO ENLARGED PLAN - THIRD FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)
A A2
1/4" = 1'-0"
PRINTED:
1 2 3 20 21 22 23 24 25
U
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722
www.opnarchitects.com
All reports, plans, specifications, computer files, field data,
notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain
the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved
T rights, including the copyright thereto.
(C) 2025 OPN Architects, Inc.
Owner
S
Project
R
CONSTRUCTION MANAGER
DCI GROUP
220 SE 6TH STREET, SUITE 200
DES MOINES, IA 50309
ELEVATOR CONSULTANT
LERCH BATES
7625 GOLDEN TRIANGLE DRIVE,
SUITE T
EDEN PRAIRIE, MN 55344
Mechanical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Electrical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Key Plan
OPN Project No.
Sheet Issue Date
Sheet Name
Sheet Number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
6/11/2026
6:40:35
AM
STATE OF IOWA -9440.01
109 SE 13TH STREET
DES MOINES, IA 50319
STATE HISTORICAL BUILDING ELEVATOR
REPLACEMENTS
600 E LOCUST STREET
DES MOINES, IA 50319
ENLARGED PLAN - MEZZANINE - WEST - ELEVATOR 5 (6513)
L15
1/4" = 1'-0"
Revision Description Date
25832000
BID ISSUE SET 06/10/26
ENLARGED DEMO PLANS -
ELEVATOR 4 (6512) /
ELEVATOR 5 (6513)
AD103

REMOVE AND REPLACE EXISTING
SIGNAGE AND CONTROLS.
PROVIDE NEW PREFINISHED ELEVATOR
DOORS AND OPENERS - SEE ELEVATOR
SPEC. FINISH TO MATCH EXISTING.
PROVIDE NEW PREFINISHED ELEVATOR
DOORS AND OPENERS - SEE ELEVATOR
SPEC. FINISH TO MATCH EXISTING.
PROVIDE NEW PREFINISHED ELEVATOR
DOORS AND OPENERS - SEE ELEVATOR
SPEC. FINISH TO MATCH EXISTING.
EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL
EXISTING PAINTED FRAMES TO REMAIN
PROTECT IN PLACE. CLEAN, PATCH / FILL
ANY DAMAGE TO FRAME AND REPAINT.
FLOOR SIGNAGE TO BE REMOVED AND
REPLACED
FLOOR SIGNAGE TO BE REMOVED AND
REPLACED
REPLACED -
REMOVE AND REPLACE EXISTING
SIGNAGE AND CONTROLS. REQUIRED
REMOVE AND REPLACE EXISTING
SIGNAGE AND CONTROLS. REQUIRED
ELEVATOR SIGNAGE TO BE INTEGRAL TO
CONTROLS. NEW FIXTURES SHOULD
COMPLETELY COVER OLD BOXES /
SIGNAGE AND CONTROLS. REQUIRED
ELEVATOR SIGNAGE TO BE INTEGRAL TO
CONTROLS. NEW FIXTURES SHOUL
COMPLETELY COVER OLD BOXES /
PENETRATIONS.
SIGNAGE AND CONTROLS. REQUIRED
ELEVATOR SIGNAGE TO BE INTEGRAL TO
CONTROLS. NEW FIXTURES SHOULD
COMPLETELY COVER OLD BOXES /
PENETRATIONS.
CONTROLS. NEW FIXTURES SHOULD
COMPLETELY COVER OLD BOXES /
PENETRATIONS.
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION
EXISTING SHAFT AND RAILS TO REMAIN
SEE ELEVATOR SPEC FOR ELEVATOR
REQUIREMENTS.
REMOVE AND REPLACE EXISTING
ELEVATOR CEILING AND LIGHTING - SE
ELEVATOR SPEC AND DRAWINGS FOR
SPECIFIC REQUIREMENTS.
PROVIDE NEW PREFINISHED ELEVATOR
DOORS AND OPENERS -SEE ELEVATOR
SPEC. FINISH TO MATCH EXISTING
ALL EXISTING FINISHES TO BE REPLACED
IN ELEVATOR. SEE ELEVATOR SPEC AND
EXISTING PAINTED FRAMES TO REMAIN
PROTECT IN PLACE. CLEAN, PATCH / FIL
ANY DAMAGE TO FRAME AND REPAINT.
FLOOR SIGNAGE TO BE REMOVED AND
REPLACED
ELEVATOR TO BE PROVIDED / COORDINATED
WITH A COMBINATION CARD ACCESS / PIN
CODE FOR ACCESS - SEE ELECTRICAL
EXISTING COUNTERWEIGHTS - SEE
REMOVE AND REPLACE EXISTING ELEVATOR
CONTROL PANEL - SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
PROVIDE BRAILLE AND MATCH ALL LABELING
ON ALL BUTTONS, INCLUDING SIGNAGE BELOW.
ALL BRAILLE AND SIGNAGE PLATES TO BE
AFFIXED PLATES TO ELEVATOR CONTROL
PANEL FOR ABILITY TO REPLACE IN FUTURE.
ALL OTHER SIGNAGE TO BE ENGRAVED O
CONTROL PANEL.
REMOVE AND REPLACE EXISTING
ELEVATOR FINISHES -
SPEC AND ELEVATOR ELEVATION
DRAWINGS FOR SPECIFIC
REQUIREMENTS.
PROVIDE NEW ELEVATOR DOORS AND
OPENERS - SEE ELEVATOR SPEC.
ELEVATOR SIGNAGE TO BE INTEGRAL T
CONTROLS. NEW FIXTURES SHOULD
COMPLETELY COVER OLD BOXES
PENETRATIONS.
ALL EXISTING FINISHES TO BE REPLACED
IN ELEVATOR. SEE ELEVATOR SPEC AND
SEE ELECTRICAL FOR SHAFT DETECTION
REQUIREMENTS.
REMOVE AND REPLACE EXISTING
ELEVATOR FLOORING - SEE ELEVATOR
PROVIDE NEW COMPLIANT SHAFT LIGHTING -
SEE ELECTRICAL.
AND ELEVATOR ELEVATION DRAWINGS
FOR MATERIALS.
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION
GOVERNOR WITH REMOTE RESET -SEE
ELEVATOR SPEC FOR REQUIREMENTS.
POLISH AND CLEAN ALL SILLS TO
REMAIN - TYPICAL ALL ELEVATORS.
SEE ELEVATOR SPEC FOR ELEVATOR
REQUIREMENTS.
EXISTING MECHANICAL ROOM IS
CONDITIONED / VENTED - SEE MECHANICAL
SEE ELECTRICAL FOR ALL RELAYS TO
REMAIN OR BE REUSED. SEE ELECTRICAL
REMOVE AND REPLACE EXISTING ELEVATOR
CONTROLLER -
SPECIFIC REQUIREMENTS
REMOVE AND REPLACE EXISTING ELEVATOR
CONTROLLER - SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
MACHINERY - SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
REMOVE AND REPLACE EXISTING SHAFT
PROTECTION AS REQUIRED FOR NEW
INSTALL - SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
PROVIDE NEW COMPLIANT SHAFT LIGHTING
SEE ELECTRICAL.
EXISTING PIT IS DRY AND FREE OF SIGNS
OF WATER INTRUSION. THERE IS AN
EXISTING COVERED PIT THAT IS TO REMA
AS IS. PAINT COVER WITH FLOOR
REMOVE AND REPLACE ELEVATOR PIT
LADDER. NEW LADDER TO BE IN COMPLIANCE
WITH ALL CURRENT APPLICABLE CODE
REMOVE AND REPLACE EXISTING
ELEVATOR MACHINERY - SEE
MACHINERY - SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
PIT FLOOR TO BE CLEANED AND PREPPED
FOR NEW PAINT FINISH -SEE ELEVATOR
SPEC.
PIT FLOOR TO BE CLEANED AND PREPPE
FOR NEW PAINT FINISH - SEE ELEVATOR
SPEC.
PREP EXISTING FLOOR AS REQUIRED FOR
NEW PAINT FINISH - SEE SPECS
NEW PAINT FINISH -

4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
PRINTED:
1 2 3 20 21 22 23 24 25
U
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722
www.opnarchitects.com
All reports, plans, specifications, computer files, field data,
notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain
the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved
T rights, including the copyright thereto.
(C) 2025 OPN Architects, Inc.
Owner
S
Project
R
CONSTRUCTION MANAGER
DCI GROUP
220 SE 6TH STREET, SUITE 200
DES MOINES, IA 50309
ELEVATOR CONSULTANT
LERCH BATES
7625 GOLDEN TRIANGLE DRIVE,
SUITE T
EDEN PRAIRIE, MN 55344
Mechanical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Electrical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Key Plan
OPN Project No.
Sheet Issue Date
Sheet Name
Sheet Number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
6/11/2026
6:37:39
AM
REMOVE AND REPLACE EXISTING
SIGNAGE AND CONTROLS.
PROVIDE NEW PREFINISHED ELEVATOR
DOORS AND OPENERS -SEE ELEVATOR
SPEC. FINISH TO MATCH EXISTING.
PROVIDE NEW PREFINISHED ELEVATOR PROVIDE NEW PREFINISHED ELEVATOR PROVIDE NEW PREFINISHED ELEVATOR
DOORS AND OPENERS -SEE ELEVATOR DOORS AND OPENERS -SEE ELEVATOR DOORS AND OPENERS -SEE ELEVATOR
SPEC. FINISH TO MATCH EXISTING. SPEC. FINISH TO MATCH EXISTING. SPEC. FINISH TO MATCH EXISTING.
EXISTING PAINTED FRAMES TO REMAIN - EXISTING PAINTED FRAMES TO REMAIN - EXISTING PAINTED FRAMES TO REMAIN - EXISTING PAINTED FRAMES TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL PROTECT IN PLACE. CLEAN, PATCH / FILL PROTECT IN PLACE. CLEAN, PATCH / FILL PROTECT IN PLACE. CLEAN, PATCH / FILL
ANY DAMAGE TO FRAME AND REPAINT. ANY DAMAGE TO FRAME AND REPAINT. ANY DAMAGE TO FRAME AND REPAINT. ANY DAMAGE TO FRAME AND REPAINT.
STATE OF IOWA -9440.01
FLOOR SIGNAGE TO BE REMOVED AND FLOOR SIGNAGE TO BE REMOVED AND FLOOR SIGNAGE TO BE REMOVED AND FLOOR SIGNAGE TO BE REMOVED AND
109 SE 13TH STREET
REPLACED -SEE ELEVATOR SPEC. REPLACED. REPLACED. REPLACED.
DES MOINES, IA 50319
EXISTING SIGNAGE TO REMAIN. EXISTING SIGNAGE TO REMAIN.
EXISTING SIGNAGE TO REMAIN.
STATE HISTORICAL BUILDING ELEVATOR
REPLACEMENTS
600 E LOCUST STREET
EXISTING SIGNAGE TO REMAIN.
DES MOINES, IA 50319
REMOVE AND REPLACE EXISTING REMOVE AND REPLACE EXISTING REMOVE AND REPLACE EXISTING REMOVE AND REPLACE EXISTING
SIGNAGE AND CONTROLS. REQUIRED SIGNAGE AND CONTROLS. REQUIRED SIGNAGE AND CONTROLS. REQUIRED SIGNAGE AND CONTROLS. REQUIRED
ELEVATOR SIGNAGE TO BE INTEGRAL TO ELEVATOR SIGNAGE TO BE INTEGRAL TO ELEVATOR SIGNAGE TO BE INTEGRAL TO ELEVATOR SIGNAGE TO BE INTEGRAL TO
CONTROLS. NEW FIXTURES SHOULD CONTROLS. NEW FIXTURES SHOULD CONTROLS. NEW FIXTURES SHOULD CONTROLS. NEW FIXTURES SHOULD
COMPLETELY COVER OLD BOXES / COMPLETELY COVER OLD BOXES / COMPLETELY COVER OLD BOXES / COMPLETELY COVER OLD BOXES /
PENETRATIONS. PENETRATIONS. PENETRATIONS. PENETRATIONS.
PROTECT ALL EXISTING HALLWAY PROTECT ALL EXISTING HALLWAY PROTECT ALL EXISTING HALLWAY PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION. FINISHES DURING CONSTRUCTION. FINISHES DURING CONSTRUCTION. FINISHES DURING CONSTRUCTION.
IMAGE 1 IMAGE 2 IMAGE 3 IMAGE 4
1 2 3 4
EXISTING SHAFT AND RAILS TO REMAIN -
SEE ELEVATOR SPEC FOR ELEVATOR
PROVIDE NEW ELEVATOR DOORS AND REQUIREMENTS.
OPENERS -SEE ELEVATOR SPEC.
REMOVE AND REPLACE EXISTING
PROVIDE NEW PREFINISHED ELEVATOR ELEVATOR CEILING AND LIGHTING -SEE
DOORS AND OPENERS -SEE ELEVATOR ELEVATOR SPEC AND DRAWINGS FOR
SPEC. FINISH TO MATCH EXISTING. SPECIFIC REQUIREMENTS.
ALL EXISTING FINISHES TO BE REPLACED
IN ELEVATOR. SEE ELEVATOR SPEC AND
EXISTING PAINTED FRAMES TO REMAIN -
DRAWINGS FOR NEW FINISHES.
PROTECT IN PLACE. CLEAN, PATCH / FILL
ANY DAMAGE TO FRAME AND REPAINT.
FLOOR SIGNAGE TO BE REMOVED AND
ELEVATOR TO BE PROVIDED / COORDINATED REPLACED. EXISTING COUNTERWEIGHTS -SEE
WITH A COMBINATION CARD ACCESS / PIN
ELEVATOR SPEC FOR ELEVATOR
CODE FOR ACCESS -SEE ELECTRICAL.
REQUIREMENTS.
RELOCATE BUILDING MAP AS REQUIRED FOR
NEW ELEVATOR CONTROLS.
REMOVE AND REPLACE EXISTING ELEVATOR REMOVE AND REPLACE EXISTING
CONTROL PANEL -SEE ELEVATOR SPEC FOR ELEVATOR FINISHES -SEE ELEVATOR
SPECIFIC REQUIREMENTS. SPEC AND ELEVATOR ELEVATION
EXISTING SIGNAGE TO REMAIN. PROVIDE BRAILLE AND MATCH ALL LABELING DRAWINGS FOR SPECIFIC
EXISTING VENT SHAFT TO REMAIN. NO
ON ALL BUTTONS, INCLUDING SIGNAGE BELOW. REQUIREMENTS.
CHANGE.
ALL BRAILLE AND SIGNAGE PLATES TO BE
AFFIXED PLATES TO ELEVATOR CONTROL
PANEL FOR ABILITY TO REPLACE IN FUTURE.
ALL OTHER SIGNAGE TO BE ENGRAVED ON
PROVIDE NEW ELEVATOR DOORS AND
CONTROL PANEL.
OPENERS -SEE ELEVATOR SPEC.
REMOVE AND REPLACE EXISTING
SIGNAGE AND CONTROLS. REQUIRED
SEE ELECTRICAL FOR SHAFT DETECTION
ELEVATOR SIGNAGE TO BE INTEGRAL TO ALL EXISTING FINISHES TO BE REPLACED
REQUIREMENTS.
CONTROLS. NEW FIXTURES SHOULD IN ELEVATOR. SEE ELEVATOR SPEC AND
REMOVE AND REPLACE EXISTING
COMPLETELY COVER OLD BOXES / DRAWINGS FOR NEW FINISHES.
ELEVATOR FLOORING -SEE ELEVATOR
PENETRATIONS.
SPEC FOR INSTALLATION REQUIREMENTS
PROVIDE NEW COMPLIANT SHAFT LIGHTING -
AND ELEVATOR ELEVATION DRAWINGS
SEE ELECTRICAL.
FOR MATERIALS.
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION.
GOVERNOR WITH REMOTE RESET -SEE
POLISH AND CLEAN ALL SILLS TO ELEVATOR SPEC FOR REQUIREMENTS.
REMAIN -TYPICAL ALL ELEVATORS.
IMAGE 5 IMAGE 6 IMAGE 7 IMAGE 8
5 6 7 8
EXISTING SHAFT AND RAILS TO REMAIN - EXISTING SHAFT AND RAILS TO REMAIN -
SEE ELEVATOR SPEC FOR ELEVATOR SEE ELEVATOR SPEC FOR ELEVATOR EXISTING MECHANICAL ROOM IS SEE ELECTRICAL FOR ALL RELAYS TO
REQUIREMENTS. REQUIREMENTS. CONDITIONED / VENTED -SEE MECHANICAL. REMAIN OR BE REUSED. SEE ELECTRICAL
/ TELECOM FOR REQUIREMENTS.
Revision Description Date
REMOVE AND REPLACE EXISTING ELEVATOR REMOVE AND REPLACE EXISTING ELEVATOR REMOVE AND REPLACE EXISTING ELEVATOR
MACHINERY -SEE ELEVATOR SPEC FOR CONTROLLER -SEE ELEVATOR SPEC FOR CONTROLLER -SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS. SPECIFIC REQUIREMENTS. SPECIFIC REQUIREMENTS.
REMOVE AND REPLACE EXISTING SHAFT
PROTECTION AS REQUIRED FOR NEW
INSTALL -SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
PROVIDE NEW COMPLIANT SHAFT LIGHTING - EXISTING PIT IS DRY AND FREE OF SIGNS
SEE ELECTRICAL. OF WATER INTRUSION. THERE IS AN
EXISTING COVERED PIT THAT IS TO REMAIN
AS IS. PAINT COVER WITH FLOOR.
REMOVE AND REPLACE ELEVATOR PIT
LADDER. NEW LADDER TO BE IN COMPLIANCE
REMOVE AND REPLACE EXISTING
WITH ALL CURRENT APPLICABLE CODES.
ELEVATOR MACHINERY -SEE
COORDINATE EXACT LOCATION WITH
ELEVATOR SPEC FOR SPECIFIC
ELEVATOR PROVIDER.
REQUIREMENTS.
REMOVE AND REPLACE EXISTING ELEVATOR
MACHINERY -SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
PIT FLOOR TO BE CLEANED AND PREPPED PIT FLOOR TO BE CLEANED AND PREPPED
FOR NEW PAINT FINISH -SEE ELEVATOR FOR NEW PAINT FINISH -SEE ELEVATOR
SPEC. SPEC.
PREP EXISTING FLOOR AS REQUIRED FOR PREP EXISTING FLOOR AS REQUIRED FOR
25832000
NEW PAINT FINISH -SEE SPECS. NEW PAINT FINISH -SEE SPECS.
BID ISSUE SET 06/10/26
IMAGE 9 IMAGE 10 IMAGE 11 IMAGE 12
9 10 11 12
EXISTING CONDITIONS -
ELEVATOR 3 (6514)
AD201

DOORS AND OPENERS -
SPEC. FINISH TO MATCH EXISTING.
EXISTING MAGNETIC HOLDS TO REMAIN.
PROTECT DURING CONSTRUCTIO
DOORS AND OPENERS -
SPEC. FINISH TO MATCH EXISTING.
EXISTING PAINTED OPENING TO REMAIN
PROTECT IN PLACE. CLEAN, PATCH / FIL
ANY DAMAGE TO FRAME AND REPAINT.
COORDINATE NEW CONTROL FIXTURE TO
PROVIDE OPERATION IN EXISTING
LOCATION. ALLOW ROOM ON NEW
CONTROL PLATE FOR CARD ACCESS
EXISTING PAINTED OPENING TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL
DOORS AND OPENERS -SEE ELEVATOR
SPEC. FINISH TO MATCH EXISTING.
AT EACH JAMB, REMOVE PLYWOOD AND
PROVIDE NEW STAINLESS STEEL PLATE
AND CORNER GUARDS AT EACH JAMB (T
+ 4'- 0" AFF).
AT EACH JAMB, REMOVE PLYWOOD AND
PROVIDE NEW STAINLESS STEEL PLATE
AND CORNER GUARDS AT EACH JAMB (T
+4 '- 0" AFF).
RUN NEW STAINLESS STEEL PLATE FROM
INSIDE ELEVATOR JAMB EQUAL WITH
WALL TO CORNER, THEN TURN CORNER
AND RUN ON CORRIDOR WALL OVER TO
ADJACENT DOOR FRAME
RUN NEW STAINLESS STEEL PLATE FRO
INSIDE ELEVATOR JAMB EQUAL WITH
WALL TO CORNER, THEN TURN CORNER
AND RUN ON CORRIDOR WALL OVER TO
ADJACENT DOOR FRAME
EXISTING BI -PARTING DOORS TO REMAIN.
PROTECT DURING CONSTRUCTION
EXISTING BI - PARTING DOORS TO REMAIN.
PROTECT DURING CONSTRUCTION
SIGNAGE AND CONTROLS. REQUIRED
ELEVATOR SIGNAGE TO BE INTEGRAL TO
CONTROLS. NEW FIXTURES SHOULD
COMPLETELY COVER OLD BOXES /
PENETRATIONS.
COMPLETELY COVER OLD BOXES /
PENETRATIONS.
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION.
EXISTING WALL PANELS TO BE MAINTAINED -
EXISTING VENT SHAFT TO REMAIN -NO
WORK.
FIXTURES TO BE PROVIDED. SEE
ELEVATOR RCP
EXISTING WALL PANELS TO BE MAINTAINED
PREP WALLS AND PROVIDE NEW
ELECTROSTATIC PAINT FINISH
EXISTING PAINTED OPENING TO REMAIN -
PROTECT IN PLACE. CLEAN, PATCH / FILL
PROVIDE NEW COMPLIANT SHAFT LIGHTING -
SEE ELECTRICAL.
AT EACH JAMB, REMOVE PLYWOOD AND
PROVIDE NEW STAINLESS STEEL PLATE
AND CORNER GUARDS AT EACH JAMB (T
+ 4'- 0" AFF).
PROVIDE NEW ELEVATOR CONTROL
PANEL - SEE ELEVATOR SPEC.
RUN NEW STAINLESS STEEL PLATE FROM
INSIDE ELEVATOR JAMB EQUAL WITH
WALL TO CORNER, THEN TURN CORNER
AND RUN TO WALL AS SHOWN.
EXISTING COUNTERWEIGHTS - SEE
EXISTING ELEVATOR FLOOR TO REMAI
CLEAN AND POLISH EXISTING FLOOR - SEE
ELEVATOR SPECIFICATIONS.
OPENERS - SEE ELEVATOR SPEC.
ELEVATOR PROVIDER TO PROVIDE NE
SILL TRIMS AS REQUIRED TO REDUCE GAP
AT EACH FLOOR TRANSITION -
ELEVATOR SPEC
SEE ELECTRICAL FOR SHAFT DETECTION
REQUIREMENTS.
SIGNAGE AND CONTROLS. REQUIRED
ELEVATOR SIGNAGE TO BE INTEGRAL TO
CONTROLS. NEW FIXTURES SHOULD
COMPLETELY COVER OLD BOXES /
PENETRATIONS.
PIT FLOOR TO BE CLEANED AND PREPPED
FOR NEW PAINT FINISH - SEE ELEVATOR
SPEC.
PROVIDE NEW ELEVATOR DOORS AND
OPENERS - SEE ELEVATOR SPEC
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION
VENTED - SEE MECHANICAL.
ROOM LIGHTING - SEE ELECTRICAL
EXISTING CEILING HAS NON - ELEVATOR
RELATED UTILITIES RUNNING THROUG
THE SPACE. A NEW HARD LID CEILING
EXISTING CEILING HAS NON -ELEVATOR
RELATED UTILITIES RUNNING THROUGH
THE SPACE. A NEW HARD LID CEILING
WILL BE REQUIRED TO BE ADDED TO THE
SPACE.
INSTALL - SEE ELEVATOR SPEC FOR
REMOVE AND REPLACE EXISTING ELEVATOR
MACHINERY - SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
REMOVE AND REPLACE EXISTING SHAF
PROTECTION AS REQUIRED FOR NEW
INSTALL -
SPECIFIC REQUIREMENTS.
EXISTING DETECTION AND RELAYS WILL
NEED TO BE RELOCATED AS REQUIRED
FOR NEW HARD LID CEILING, SEE
ELECTRICAL FOR REQUIREMENTS.
PROVIDE NEW COMPLIANT SHAFT LIGHTIN G -
SEE ELECTRICAL.
REMOVE AND REPLACE EXISTING
ELEVATOR MACHINERY -SEE
SEE ELECTRICAL FOR DISCONNECTS
CONTROLLERS TO REMAIN OR BE
REUSED. SEE ELECTRICAL / TELECOM
FOR REQUIREMENTS.
REMOVE AND REPLACE ELEVATOR PIT
LADDER. NEW LADDER TO BE IN
COMPLIANCE WITH ALL CURRENT
PREP EXISTING FLOOR AS REQUIRED FOR
NEW PAINT FINISH -
PIT FLOOR TO BE CLEANED AND PREPPED
FOR NEW PAINT FINISH -SEE ELEVATOR
SPEC.

4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
PRINTED:
1 2 3 20 21 22 23 24 25
U
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722
www.opnarchitects.com
All reports, plans, specifications, computer files, field data,
notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain
the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved
T rights, including the copyright thereto.
(C) 2025 OPN Architects, Inc.
Owner
S
Project
R
CONSTRUCTION MANAGER
DCI GROUP
220 SE 6TH STREET, SUITE 200
DES MOINES, IA 50309
ELEVATOR CONSULTANT
LERCH BATES
7625 GOLDEN TRIANGLE DRIVE,
SUITE T
EDEN PRAIRIE, MN 55344
Mechanical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Electrical Engineer
KCL ENGINEERING
300 4TH STREET
WEST DES MOINES, IA 50317
Key Plan
OPN Project No.
Sheet Issue Date
Sheet Name
Sheet Number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
6/11/2026
6:37:40
AM
PROVIDE NEW PREFINISHED ELEVATOR
DOORS AND OPENERS -SEE ELEVATOR
SPEC. FINISH TO MATCH EXISTING.
PROVIDE NEW PREFINISHED ELEVATOR
EXISTING MAGNETIC HOLDS TO REMAIN.
DOORS AND OPENERS -SEE ELEVATOR PROTECT DURING CONSTRUCTION.
SPEC. FINISH TO MATCH EXISTING.
EXISTING PAINTED OPENING TO REMAIN - COORDINATE NEW CONTROL FIXTURE TO
EXISTING PAINTED OPENING TO REMAIN - PROTECT IN PLACE. CLEAN, PATCH / FILL EXISTING PAINTED OPENING TO REMAIN - PROVIDE OPERATION IN EXISTING
PROTECT IN PLACE. CLEAN, PATCH / FILL ANY DAMAGE TO FRAME AND REPAINT. PROTECT IN PLACE. CLEAN, PATCH / FILL LOCATION. ALLOW ROOM ON NEW
ANY DAMAGE TO FRAME AND REPAINT. ANY DAMAGE TO FRAME AND REPAINT. CONTROL PLATE FOR CARD ACCESS
CONTROLLER TO REPLACE USER KEY
STATE OF IOWA -9440.01
PROVIDE NEW PREFINISHED ELEVATOR COORDINATE ALL REQUIRED SIGNAGE CONTROL.
109 SE 13TH STREET
DOORS AND OPENERS -SEE ELEVATOR LOCATIONS WITH ARCHITECT / OWNER
AT EACH JAMB, REMOVE PLYWOOD AND SPEC. FINISH TO MATCH EXISTING. PRIOR TO INSTALLATION. DES MOINES, IA 50319
PROVIDE NEW STAINLESS STEEL PLATE
AND CORNER GUARDS AT EACH JAMB (TO
+4'-0" AFF).
AT EACH JAMB, REMOVE PLYWOOD AND
PROVIDE NEW STAINLESS STEEL PLATE STATE HISTORICAL BUILDING ELEVATOR
AND CORNER GUARDS AT EACH JAMB (TO
REPLACEMENTS
+4'-0" AFF).
600 E LOCUST STREET
RUN NEW STAINLESS STEEL PLATE FROM RUN NEW STAINLESS STEEL PLATE FROM DES MOINES, IA 50319
INSIDE ELEVATOR JAMB EQUAL WITH INSIDE ELEVATOR JAMB EQUAL WITH
WALL TO CORNER, THEN TURN CORNER WALL TO CORNER, THEN TURN CORNER
AND RUN ON CORRIDOR WALL OVER TO AND RUN ON CORRIDOR WALL OVER TO
ADJACENT DOOR FRAME. ADJACENT DOOR FRAME.
REMOVE AND REPLACE EXISTING
REMOVE AND REPLACE EXISTING SIGNAGE AND CONTROLS. REQUIRED EXISTING BI-PARTING DOORS TO REMAIN. EXISTING BI-PARTING DOORS TO REMAIN.
SIGNAGE AND CONTROLS. REQUIRED ELEVATOR SIGNAGE TO BE INTEGRAL TO PROTECT DURING CONSTRUCTION. PROTECT DURING CONSTRUCTION.
ELEVATOR SIGNAGE TO BE INTEGRAL TO CONTROLS. NEW FIXTURES SHOULD
CONTROLS. NEW FIXTURES SHOULD COMPLETELY COVER OLD BOXES /
COMPLETELY COVER OLD BOXES / PENETRATIONS.
PENETRATIONS.
PROTECT ALL EXISTING HALLWAY
PROTECT ALL EXISTING HALLWAY FINISHES DURING CONSTRUCTION. PROTECT ALL EXISTING HALLWAY PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION. FINISHES DURING CONSTRUCTION. FINISHES DURING CONSTRUCTION.
IMAGE 13 IMAGE 14 IMAGE 15 IMAGE 16
13 14 15 16
EXISTING WALL PANELS TO BE MAINTAINED - EXISTING VENT SHAFT TO REMAIN -NO
PREP WALLS AND PROVIDE NEW WORK.
EXISTING ELEVATOR LIGHTING TO BE ELECTROSTATIC PAINT FINISH.
REMOVED AND NEW SURFACE MOUNTED
FIXTURES TO BE PROVIDED. SEE
ELEVATOR RCP.
REMOVE ALL EXISTING SIGNAGE
EXISTING WALL PANELS TO BE MAINTAINED - COMPLETE AND PROVIDE NEW CODE
EXISTING PAINTED OPENING TO REMAIN -
PREP WALLS AND PROVIDE NEW COMPLIANT SIGNAGE.
PROTECT IN PLACE. CLEAN, PATCH / FILL PROVIDE NEW COMPLIANT SHAFT LIGHTING -
ELECTROSTATIC PAINT FINISH.
ANY DAMAGE TO FRAME AND REPAINT. SEE ELECTRICAL.
WALLS TO MATCH EXISTING COLOR.
CEILING TO BE WHITE.
AT EACH JAMB, REMOVE PLYWOOD AND
PROVIDE NEW STAINLESS STEEL PLATE
PROVIDE NEW ELEVATOR CONTROL
AND CORNER GUARDS AT EACH JAMB (TO
PANEL -SEE ELEVATOR SPEC. EXISTING SHAFT AND RAILS TO REMAIN -
+4'-0" AFF).
SEE ELEVATOR SPEC FOR ELEVATOR
REQUIREMENTS.
RUN NEW STAINLESS STEEL PLATE FROM EXISTING COUNTERWEIGHTS -SEE
INSIDE ELEVATOR JAMB EQUAL WITH EXISTING ELEVATOR FLOOR TO REMAIN. ELEVATOR SPEC FOR ELEVATOR
WALL TO CORNER, THEN TURN CORNER CLEAN AND POLISH EXISTING FLOOR -SEE REQUIREMENTS.
AND RUN TO WALL AS SHOWN. ELEVATOR SPECIFICATIONS.
PROVIDE NEW ELEVATOR DOORS AND
OPENERS -SEE ELEVATOR SPEC.
ELEVATOR PROVIDER TO PROVIDE NEW
SILL TRIMS AS REQUIRED TO REDUCE GAP
REMOVE AND REPLACE EXISTING AT EACH FLOOR TRANSITION -SEE
SEE ELECTRICAL FOR SHAFT DETECTION
SIGNAGE AND CONTROLS. REQUIRED ELEVATOR SPEC. REQUIREMENTS.
ELEVATOR SIGNAGE TO BE INTEGRAL TO
CONTROLS. NEW FIXTURES SHOULD
COMPLETELY COVER OLD BOXES /
PENETRATIONS. PIT FLOOR TO BE CLEANED AND PREPPED
FOR NEW PAINT FINISH -SEE ELEVATOR
PROVIDE NEW ELEVATOR DOORS AND
SPEC.
OPENERS -SEE ELEVATOR SPEC.
PROTECT ALL EXISTING HALLWAY
FINISHES DURING CONSTRUCTION.
IMAGE 17 IMAGE 18 IMAGE 19 IMAGE 20
17 18 19 20
EXISTING MACHINE ROOM IS CONDITIONED /
EXISTING SHAFT AND RAILS TO REMAIN - VENTED -SEE MECHANICAL.
SEE ELEVATOR SPEC FOR ELEVATOR REMOVE AND PROVIDE NEW MACHINE
REQUIREMENTS. ROOM LIGHTING -SEE ELECTRICAL.
EXISTING CEILING HAS NON-ELEVATOR
RELATED UTILITIES RUNNING THROUGH
THE SPACE. A NEW HARD LID CEILING SEE ELECTRICAL FOR ALL RELAYS TO
REMOVE AND REPLACE EXISTING SHAFT WILL BE REQUIRED TO BE ADDED TO THE REMAIN OR BE REUSED. SEE ELECTRICAL
PROTECTION AS REQUIRED FOR NEW SPACE. / TELECOM FOR REQUIREMENTS.
EXISTING CEILING HAS NON-ELEVATOR
INSTALL -SEE ELEVATOR SPEC FOR
RELATED UTILITIES RUNNING THROUGH
SPECIFIC REQUIREMENTS.
REMOVE AND REPLACE EXISTING ELEVATOR THE SPACE. A NEW HARD LID CEILING
CONTROLLER -SEE ELEVATOR SPEC FOR WILL BE REQUIRED TO BE ADDED TO THE Revision Description Date
SPECIFIC REQUIREMENTS. SPACE.
REMOVE AND REPLACE EXISTING ELEVATOR
MACHINERY -SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
REMOVE AND REPLACE EXISTING SHAFT
PROTECTION AS REQUIRED FOR NEW
INSTALL -SEE ELEVATOR SPEC FOR
SPECIFIC REQUIREMENTS.
EXISTING DETECTION AND RELAYS WILL
PROVIDE NEW COMPLIANT SHAFT LIGHTING - REMOVE AND REPLACE EXISTING
NEED TO BE RELOCATED AS REQUIRED
SEE ELECTRICAL. ELEVATOR MACHINERY -SEE
FOR NEW HARD LID CEILING, SEE
ELEVATOR SPEC FOR SPECIFIC
ELECTRICAL FOR REQUIREMENTS.
REQUIREMENTS.
SEE ELECTRICAL FOR DISCONNECTS /
CONTROLLERS TO REMAIN OR BE
REUSED. SEE ELECTRICAL / TELECOM
FOR REQUIREMENTS.
REMOVE AND REPLACE ELEVATOR PIT
LADDER. NEW LADDER TO BE IN
COMPLIANCE WITH ALL CURRENT
APPLICABLE CODES. COORDINATE EXACT
PREP EXISTING FLOOR AS REQUIRED FOR
LOCATION WITH ELEVATOR PROVIDER.
NEW PAINT FINISH -SEE SPECS.
PIT FLOOR TO BE CLEANED AND PREPPED
FOR NEW PAINT FINISH -SEE ELEVATOR
SPEC.
IMAGE 21 IMAGE 22 IMAGE 23 IMAGE 24
21 22 23 24 25832000
BID ISSUE SET 06/10/26
EXISTING CONDITIONS -
ELEVATOR 4 (6512)
AD202

This page summarizes the opportunity, including an overview and a preview of the attached documents.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Pearson Hall-Rooms 1116 and 1138 Remodel Prebid Meeting: 7/27/2026 2:00:00 PM Prebid location:

Iowa State University

Bid Due: 8/11/2026

Bid Information Bid Number RFB953400-01 Solicitation ATOD Will Call Ramp Replacement Solicitation Type

State Government of Iowa

Bid Due: 7/28/2026

ATOD Will Call Ramp Replacement ATOD Will Call Ramp Replacement Open: 6/29/2026 8:00

Iowa Department of Administrative Services

Bid Due: 7/28/2026

Pearson Hall-Rooms 1116 and 1138 Remodel Prebid Meeting: 7/27/2026 2:00:00 PM Prebid location:

Iowa State University

Bid Due: 8/11/2026