Crossroads Building Electrical System Upgrade & Install

Agency: Laramie County Community College
State: Wyoming
Type of Government: State & Local
Caegory:
  • Y - Construction of Structures and Facilities
Posted Date: Mar 1, 2018
Due Date: Mar 13, 2018
Solicitation No: IFB-18127
Bid Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Quote/Bid/ Proposal Reference # Documents Title or Description Pre-Bid or Pre-Proposal Meeting or Tour Document Due Date Awarded To

IFB-18127

Crossroads Building Electrical System Upgrade & Install

A mandatory pre-bid meeting will be held on Mar. 7, 2018 at 10 a.m. in the College Community Center (CCC-178). Doors will be locked at 10:00 a.m.
  • Questions due, via email, no later than Mar. 13, 2018 to jspezzano@lccc.wy.edu .
  • Bids due date: Mar. 22, 2018 by 3 p.m. in Administration AM-108.

Attachment Preview

1
E
D
C
B
A
1
2
3
4
SYMBOL
POWER LEGEND
(Not all symbols listed below are used on these drawings)
DESCRIPTION
SYMBOL
DESCRIPTION
SINGLE RECEPTACLE
PM
PLUG MOLD (MULTI-OUTLET ASSEMBLY)
DUPLEX RECEPTACLE
WM
WIREMOLD (SURFACE RACEWAY)
DOUBLE DUPLEX RECEPTACLE
CONDUIT CONCEALED
DUPLEX RECEPTACLE, HALF SWITCHED
CLG DUPLEX RECEPTACLE, CEILING MOUNTED
DUPLEX RECEPTACLE, FLOOR MOUNTED
CONDUIT EXPOSED
CONDUIT, UNDERGROUND OR CONCEALED IN FLOOR
AS ALLOWED PER SPECIFICATIONS
CONDUIT TURNING DOWN
DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED
CONDUIT TURNING UP
SPECIAL RECEPTACLE
SPECIAL RECEPTACLE, FLOOR MOUNTED
J
JUNCTION BOX, WALL OR CEILING MOUNTED
A-1,3,5
CONDUIT CAPPED
BRANCH CIRCUIT HOME RUN, NUMBER OF ARROWS INDICATES
NUMBER OF CIRCUITS, SUBSCRIPTS INDICATE PANEL & CIRCUITS
GROUND BAR
J
JUNCTION BOX, FLOOR MOUNTED
MAIN SWITCHBOARD/DISTRIBUTION CENTER
M
MOTOR
T
TRANSFORMER
DISCONNECT SWITCH (NON-FUSED)
CT
CURRENT TRANSFORMER
DISCONNECT SWITCH (FUSED)
T
THERMOSTAT
VARIABLE SPEED DRIVE WITH DISCONNECT
M
UTILITY METER
ELECTRICAL PANELBOARD, CONTROL PANEL, OR OTHER
CABINET AS NOTED
GANN
A-1
GENERATOR ANNUNCIATOR PANEL
SHADING INDICATES EMERGENCY SYSTEM
TEXT INDICATES PANEL AND CIRCUIT DESIGNATION
LIGHTING LEGEND
(Not all symbols listed below are used on these drawings)
SYMBOL
a
A
DESCRIPTION
SHADING INDICATES EM SYSTEM, LOWER CASE SUBSCRIPT INDICATES
SWITCHING, UPPER CASE SUBSCRIPT INDICATES LUMINAIRE TYPE (TYP)
SURFACE OR PENDANT MOUNTED LUMINAIRE
SYMBOL
DESCRIPTION
DECORATIVE ADJUSTABLE ACCENT DOWNLIGHT
SQUARE DOWNLIGHT
LENSED TROFFER
SQUARE WALL WASH DOWNLIGHT
DIRECT/INDIRECT TROFFER
SQUARE ADJUSTABLE ACCENT DOWNLIGHT
PATIENT OVERBED LIGHT
SQUARE DOWNLIGHT
DIRECT/INDIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT
SQUARE WALL WASH DOWNLIGHT
INDIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT
SQUARE ADJUSTABLE ACCENT DOWNLIGHT
DIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT
DECORATIVE PENDANT
DIRECT/INDIRECT DISTRIBUTION, WALL MOUNT LINEAR
PENDANT
INDIRECT DISTRIBUTION, WALL MOUNT LINEAR
RECESS MOUNTED WALL LUMINAIRE
DIRECT DISTRIBUTION, WALL MOUNT LINEAR
WALL PACK OR EXTERIOR NON-DECORATIVE WALL SIGNAGE
DECORATIVE LINEAR WALLMOUNT
DECORATIVE SCONCE
STRIP LINEAR WALLMOUNT
DECORATIVE POLE
SURFACE OR PENDANT MOUNTED STRIP OR INDUSTRIAL LUMINAIRE
POLE
THEATRICAL PIPE OR TRACK LIGHTING
TRACK HEAD
SURFACE DOWNLIGHT
K PC
BOLLARD
PORCELAIN KEYLESS LAMPHOLDER, BRYANT #5228 W/ 100W A19
I.F. LAMP. 'PC' INDICATES PULLCHAIN
EMERGENCY LIGHTING UNIT
DOWNLIGHT
WALL WASH DOWNLIGHT
EXTERIOR STAKE MOUNTED
DOCK LIGHT
ADJUSTABLE ACCENT DOWNLIGHT
DECORATIVE DOWNLIGHT
DARKROOM SAFE LIGHT (TWO COMPARTMENT SHOWN)
UNDERCABINET LIGHT
DECORATIVE WALL WASH DOWNLIGHT
EXIT LIGHT, ARROWS AS INDICATED, FACES INDICATED BY SHADING
SYMBOL
Sa
S2
S3
S4
SK
SM
SD
SPI
SP
SLV
CONTROLS LEGEND
(Not all symbols listed below are used on these drawings)
DESCRIPTION
SYMBOL
DESCRIPTION
SINGLE POLE SWITCH (SUBSCRIPT DENOTES SWITCHING)
TWO POLE SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
KEY OPERATED SWITCH
SVS
S EP
STO
S MC
S
VARIABLE SPEED/SPEED CONTROLLER SWITCH
EXPLOSION PROOF SWITCH
THERMAL OVERLOAD SWITCH
MOMENTARY CONTACT SWITCH
COMBINATION SWITCH AND DUPLEX RECEPTACLE
MANUAL SWITCH, HORSEPOWER RATE
P
PHOTOCELL
DIMMER SWITCH
SWITCH WITH PILOT LIGHT
(PILOT LIGHT IS 'ON' WHEN SWITCH IS 'ON')
SWITCH WITH PILOT LIGHT LOCATOR
(CONTINUOUSLY LIGHTED HANDLE)
LOW VOLTAGE SWITCH
PUSH BUTTON
TC
TIME CLOCK
OCCUPANCY SENSOR - WALL MOUNTED
IR=INFRARED, US=ULTRASONIC, DT=DUAL TECHNOLOGY
REFERENCE SYMBOLS LEGEND
(Not all symbols listed below are used on these drawings)
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
1
KEY NOTE REFERENCE
1
KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE
LPA-#
TYPICAL CIRCUIT NUMBER
E
EXISTING TO REMAIN
TG#
TYPICAL LUMINAIRE TYPE
X
X
TYPICAL ROOM REFERENCE (TOP = RM #, BOTTOM = FLR)
R
EXISTING TO BE REMOVED
RL
EXISTING TO BE RELOCATED
UH
MECHANICAL EQUIPMENT REFERENCE
ER
EXISTING TO REMAIN - REPLACE DEVICE
LC1
LIGHTING CONTROL / EQUIPMENT REFERENCE
RR
EXISTING TO BE REMOVED AND REPLACED
SYMBOL
A
AC
AFF
AFG
ANN
ARF
ASSD
ATS
BFG
C
CATV
CB
CCTV
(E)
EM
EMDC
EP
EPO
EVO
EWC
FA
G
GCP
GFCI
HOA
IG
MAX
MCB
MCC
MDC
ABBREVIATIONS LEGEND
(Not all symbols listed below are used on these drawings)
DESCRIPTION
SYMBOL
DESCRIPTION
AMPERES
ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE
OF DEVICE, +6" ABOVE COUNTER OR BACK SPLASH
ABOVE FINISHED FLOOR
MCP
MOTOR CIRCUIT PROTECTOR
MEC
SEE MECHANICAL EQUIPMENT SCHEDULE
MIN
MINIMUM
ABOVE FINISHED GRADE
MLO
MAIN LUGS ONLY
ANNUNCIATOR
MTS
MANUAL TRANSFER SWITCH
ABOVE RAISED FLOOR
NC
NORMALLY CLOSED
AIR SAMPLING SMOKE DETECTION
NIC
NOT IN CONTRACT
AUTOMATIC TRANSFER SWITCH
NL
NIGHT LIGHT
BELOW FINISHED GRADE
NO
NORMALLY OPEN
CONDUIT
NTS
NOT TO SCALE
CABLE TELEVISION
OC
ON CENTER
CIRCUIT BREAKER
OFCI
OWNER FURNISHED, CONTRACTOR INSTALLED
CLOSED CIRCUIT TELEVISION
OFOI
OWNER FURNISHED, OWNER INSTALLED
EXISTING
OSWF
ON SITE WORK FORCE
EMERGENCY
PB
PULL BOX
EMERGENCY MAIN DISTRIBUTION CENTER
SB
STAND-BY
EXPLOSION PROOF
SDC
SUB-DISTRIBUTION CENTER
EMERGENCY POWER OFF
SPD
SURGE PROTECTIVE DEVICE
EMERGENCY VENTILATION ON/OFF
TP
TAMPER PROOF
ELECTRIC WATER COOLER
TYP
TYPICAL
FIRE ALARM
UF
UNDER FLOOR
GROUND
UG
UNDER GROUND
GENERATOR CONTROL PANEL
UON
UNLESS OTHERWISE NOTED
GROUND FAULT CIRCUIT INTERRUPTER
UPS
UNINTERRUPTIBLE POWER SUPPLY
HAND OFF AUTOMATIC
V
VOLTS
ISOLATED GROUND
VFD
VARIABLE FREQUENCY DRIVE
MAXIMUM
W/
WITH
MAIN CIRCUIT BREAKER
W/O
WITHOUT
MOTOR CONTROL CENTER
WP
WEATHER PROOF
MAIN DISTRIBUTION CENTER
XFMR
TRANSFORMER
SYMBOL
FIRE ALARM SYSTEM LEGEND
(Not all symbols listed below are used on these drawings)
DESCRIPTION
SYMBOL
DESCRIPTION
FACP
FAPS
FSA
FAA
GZM
RACP
FSC
FAD
P
F
UV
FIRE ALARM CONTROL PANEL
FIRE ALARM (NAC) POWER SUPPLY
FIRE ALARM SYSTEM ANNUNCIATOR PANEL (GRAPHIC/LED)
REMOTE ANNUNCIATOR PANEL
GRAPHIC ZONE MAP
RESCUE ASSISTANCE SYSTEM HEAD END UNIT
FIRE FIGHTER SMOKE CONTROL PANEL
FIRE ALARM DIRECTORY ANNUNCIATOR
SMOKE DETECTOR (P=PHOTOELECTRIC, SB=WITH SOUNDER BASE,
BR=BEAM RECEIVER, BT=BEAM TRANSMITTER)
THERMAL DETECTOR F=FIXED TEMPERATURE,
R=FIXED TEMPERATURE & RATE OF RISE (TEMP. RATING)
FLAME DETECTOR (UV=ULTRAVIOLET, IR=INFRARED)
DUCT SMOKE DETECTOR S=SUPPLY, R=RETURN
M
MANUAL PULL STATION
AIM
ADDRESSABLE INPUT MODULE
AOM ADDRESSABLE OUTPUT MODULE
AUDIOVISUAL DEVICE (H##cd=HORN/STROBE COMBINATION
H15cd S=SPEAKER/STROBE COMBINATION, C=CHIME/STROBE COMBINATION)
H
AUDIBLE DEVICE (H=HORN, S=SPEAKER, C=CHIME)
15cd FIRE ALARM STROBE (cd= CANDELA RATING 15, 30, 75, 110)
J
EMERGENCY TELEPHONE STATION (J=JACK, H=HANDSET)
RA
RESCUE ASSISTANCE TELEPHONE STATION)
MAGNETIC DOOR HOLD
TAMPER SWITCH
FLOW DETECTOR SWITCH
PRESSURE SWITCH
RTS DUCT DETECTOR REMOTE INDICATOR ALARM AND TEST
REMOTE INDICATOR LIGHT
FSD FIRE/SMOKE DAMPER
CO
CARBON MONOXIDE ALARM/DETECTOR
ONE-LINE DIAGRAM LEGEND
(Not all symbols listed below are used on these drawings)
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
DISCONNECT SWITCH
A
PANELBOARD "A"
DISCONNECT SWITCH, FUSED
PM
EM=ENERGY METER, PM=POWER METER, CM=CIRCUIT MONITOR
CIRCUIT BREAKER
VS
VOLTMETER TEST SWITCH
FUSE
AS
AMMETER TEST SWITCH
GROUND
T
#
STEP DOWN TRANSFORMER, ## INDICATES KVA
TK
K-RATED STEP DOWN TRANSFORMER
#
## INDICATES KVA, # INDICATES K RATING
CURRENT TRANSFORMER
V
VOLTMETER
A
AMMETER
XXX
SEE FEEDER/MEC/TRANSFORMER SCHEDULES FOR FEEDER SIZE
G
ENGINE GENERATOR
POTENTIAL TRANSFORMER
CONTACTOR/RELAY/CAPACITOR (AS NOTED)
OR
SERVICE ENTRANCE TRANSFORMER
TRANSFER SWITCH - ATS=AUTOMATIC, MTS=MANUAL
M
METER
GFI
GROUND FAULT INTERRUPTER
EQUIPMENT ENCLOSURE
SPD
SURGE PROTECTIVE DEVICE
SERVICE WEATHERHEAD
ST
SHUNT TRIP
ISCA
Ka
Ea
M
SHORT CIRCUIT CURRENT AVAILABLE
KIRK KEY INTERLOCK, SUBSCRIPT INDICATES INTERLOCKED GROUP
ELECTRICAL INTERLOCK, SUBSCRIPT INDICATES INTERLOCKED GROUP
MECHANICAL INTERLOCK
TERMINATIONS LB=LOAD BREAK, NLB=NO LOAD BREAK
DRAW-OUT DEVICE
PLUG-IN DEVICE
EO
ELECTRICALLY OPERATED
5
GENERAL NOTES:
1. FOR REMODELING, WORK INCLUDED IS DENOTED IN BOLD. EXISTING
CONDITIONS TO REMAIN ARE DENOTED LIGHTLY.
2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE.
IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE
CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE
CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE
OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING
DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK.
3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE
NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE
SURROUNDING AREA.
4. ALL PENETRATIONS FOR RACEWAY AND CABLE THAT ARE BY THE
CONTRACTOR, WHICH PENETRATE FLOORS, FIRE AND/OR SMOKE BARRIERS
AND SEPERATIONS SHALL BE SEALED WITH A SYSTEM SPECIFICALLY U.L.
APPROVED FOR THE APPLICATION. REFER TO ARCHITECTURAL DRAWINGS
FOR FIRE ASSEMBLIES AND RATINGS.
5. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL
EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR
PRIOR TO ROUGH-IN AND ORDERING MATERIALS OR EQUIPMENT.
6. COORDINATE OUTAGES WITH OWNER TWO WEEKS IN ADVANCE. PROVIDE
WRITTEN METHOD OF PROCEDURES WHEN OUTAGE AFFECTS LIFE SAFETY
OR BUILDING SECURITY SYSTEMS.
7. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM
OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS.
CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF
ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO
CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE
DRAWINGS.
8. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER,
HOMERUN AND BRANCH CIRCUITS.
DEMOLITION NOTES:
1. UNLESS NOTED OTHERWISE, BOLD ITEMS INDICATE EQUIPMENT, DEVICES,
ETC. TO BE REMOVED WHILE EXISTING CONDITIONS TO REMAIN ARE
DENOTED WITH A LIGHTER PEN WEIGHT. REFER TO SPECIFICATIONS FOR
DETAILED REQUIREMENTS ON REMODEL/DEMOLITION RESPONSIBILITIES.
2. DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED.
CONTRACTOR SHALL VISIT SITE TO DETERMINE AND COORDINATE THE
EXACT EXTENT OF DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE
CONTRACT DOCUMENTS PRIOR TO QUOTATION. NO EXTRAS WILL BE
ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS
INDICATED BY THE CONTRACT DOCUMENTS. REWORK EXISTING
TERMINATIONS, CONNECTIONS, CONDUIT, WIRING, ETC. TO ACCEPT NEW
WORK. MAINTAIN CIRCUIT CONTINUITY TO EXISTING CIRCUITS AND DEVICES
TO REMAIN OR REMODEL/DEMOLITION DETAILED REQUIREMENTS TO BE
RELOCATED. PRIOR TO COMMENCEMENT OF ANY DEMO WORK, CONFIRM
EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR
RESOLUTION.
3. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR
ENTIRETY INCLUDING ALL WIRING AND EXPOSED CONDUIT AND CONDUIT
SUPPORTS BACK TO POINT OF ORIGIN OR NEXT DEVICE TO REMAIN.
REMOVED ITEMS SHALL BE TURNED OVER TO THE OWNER, UNLESS NOTED
OTHERWISE, AND STORED IN THE AREA DESIGNATED BY THE OWNER.
REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER
CHOOSES NOT TO ACCEPT.
4. WHERE EXISTING CONDUITS ARE SHOWN TO BE REMOVED AND HAVE BEEN
ROUTED IN CONCRETE FLOOR SLABS, CONCRETE WALLS OR CONCRETE
CEILINGS, THEY SHALL BE CUT BACK FLUSH WITH CONCRETE. FILL WITH
GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE
SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED.
5. REUSE EXISTING CONDUIT WHERE CURRENT NEC AND LOCAL CODE
REQUIREMENTS ARE MAINTAINED. PROVIDE NEW CONDUIT AND WIRE FOR
NEW INSTALLATIONS AND EXTENSION OF EXISTING INSTALLATIONS. REUSE
EXISTING CONDUIT IN PLACE, DO NOT REINSTALL EXISTING CONDUIT.
PROVIDE LABELING PER SPECIFICATIONS FOR REUSED CONDUIT.
6. RELOCATED EQUIPMENT AND DEVICES ARE TO BE CLEANED OF ALL
FOREIGN MATERIAL. REPLACE EQUIPMENT OR DEVICES WHICH ARE
DEFECTIVE OR DAMAGED DURING RELOCATION.
7. WHERE EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO
BE REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE
PATCHED TO MATCH ORIGINAL FINISH. BLANK COVERPLATES OVER
EXISTING BOXES ARE NOT ACCEPTABLE, UNLESS NOTED OTHERWISE.
6
LIGHTING PLAN NOTES:
1. REFER TO ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS
FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES.
2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING,
DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR
COORDINATION REQUIREMENTS.
3. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V
CIRCUIT.
4. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT
CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE
INDICATED. WHERE CIRCUITS ARE COMBINED WITHIN A SINGLE CONDUIT,
PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR
INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE
CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES.
5. FIELD COORDINATE EXACT LOCATION OF CEILING MOUNTED OCCUPANCY
SENSORS PER MANUFACTURER'S INSTRUCTIONS. OCCUPANCY/VACANCY
SENSING DEVICES ARE SHOWN FOR GENERAL DESIGN INTENT ONLY.
CONTRACTOR SHALL PROVIDE THE TYPE AND QUANTITY OF
OCCUPANCY/VACANCY SENSING DEVICES AS NECESSARY FOR PROPER
COVERAGE AND CONTROL OF LUMINAIRES WHERE INDICATED ON THE
LIGHTING PLANS. FIELD ADJUSTMENT TO DEVICE LOCATIONS SHALL BE
MADE AS REQUIRED TO CAPTURE ALL OCCUPANTS, WHETHER SITTING AT A
DESK OR MOVING AROUND THE SPACE. ADDTIONAL DEVICES SHALL BE
PROVIDED AND FIELD ADJUSTMENTS SHALL BE MADE AS NECESSARY, AT NO
ADDITIONAL COST TO OWNER. CONTRACTOR SHALL PROVIDE A COMPLETE
AND OPERATIONAL SYSTEM.
6. ALL EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO PANEL
EM IN ADJACENT STUDENT SERVICES BUILDING TO THE EAST. CIRCUIT
SHOWN ON LIGHTING PLANS MUST BE FIELD VERIFIED BY CONTRACTOR.
hord|coplan|macht
1331 Nineteenth Street
Denver, CO. 80202
P 303.607.0977
www.hcm2.com
CONSULTANT:
POWER PLAN NOTES:
1. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING
ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL
MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT.
2. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL
EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR
PRIOR TO ROUGH-IN.
3. PROVIDE FUSES SIZED PER EQUIPMENT MANUFACTURER'S REQUIREMENTS.
4. DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY AND
SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS TO SUIT EQUIPMENT AND
SPACE. DISCONNECT SWITCHES SHALL BE WITHIN SIGHT OF THE
EQUIPMENT THEY SERVE AND MOUNTED AT 6'-3", MAXIMUM, TO TOP OF
CABINET. MAINTAIN NEC WORK SPACE REQUIREMENTS.
5. RECEPTACLES INDICATED TO BE MOUNTED ABOVE COUNTER ARE TO BE
MOUNTED HORIZONTALLY 6" ABOVE COUNTER UNLESS OTHERWISE NOTED.
6. PROVIDE 4-SQUARE, ELECTRICAL BOX, SINGLE GANG MUD RING AND BLANK
SINGLE GANG COVER PLATE FOR ALL THERMOSTAT LOCATIONS. ROUTE 1"
CONDUIT WITH PULL WIRE TO 6" ABOVE ACCESSIBLE CEILING. PROVIDE
INSULATED THROAT CONNECTOR ON CONDUIT END.
7. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL AND
FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE
OR SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH-IN.
8. NO RECEPTACLES SHALL BE MOUNTED BELOW +18" AFF.
9. PROVIDE ISOLATED GROUND FOR EACH CIRCUIT TO FURNITURE PARTITION
AND POWER POLE LOCATIONS.
10. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V CIRCUIT.
11. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT
CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE
INDICATED. WHERE CIRCUITS ARE COMBINED WITHIN A SINGLE CONDUIT,
PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR
INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE
CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES.
12. GFCI RECEPTACLES ARE NOT GENERALLY SHOWN ON DRAWINGS. ALL
RECEPTACLE OUTLETS LOCATED IN TOILET ROOMS, OUTDOOR LOCATIONS,
MECHANICAL ROOMS, WITHIN 6 FEET OF A SINK, OR OTHER WET LOCATIONS
SHALL BE PROVIDED WITH GFI DEVICE AT PANEL BREAKER.
FIRE ALARM PLAN NOTES:
1. FIRE ALARM EQUIPMENT AND DEVICES SHOWN ON THESE DRAWING
INDICATE THE INTENT, PERFORMANCE, AND SCOPE OF THE SYSTEM. THE
FULL DESIGN OF THE FIRE ALARM SYSTEM SHALL BE BE PROVIDED AS A
DEFERRED SUBMITTAL BY THIS CONTACTOR. THE CONTRACTOR SHALL
PROVIDE APPROPRIATE SHOP DRAWINGS AND DESIGN SUBMITTALS FOR
APPROVAL BY THE LOCAL FIRE DEPARTMENT AND/OR THE AUTHORITY
HAVING JURISDICTION. THE ELECTRICAL ENGINEER OF RECORD AT CATOR,
RUMA & ASSOCIATES, CO. WILL NOT BE RESPONSIBLE FOR SEALING AND
SIGNING THE FIRE ALARM SYSTEM SHOP DRAWING SUBMITTALS PROVIDED
BY THE CONTRACTOR. CONTRACTOR SHALL MAKE NECESSARY
ARRANGEMENTS IN JURISDICTIONS WHERE THIS IS REQUIRED AND INCLUDE
COSTS IN BID.
2. LOCATE SMOKE DETECTORS PER NFPA 72 AND MANUFACTURERS
REQUIREMENTS. THE LOCATIONS OF SMOKE DETECTORS ON THE DRAWINGS
ARE DIAGRAMMATIC ONLY. DETECTORS SHALL NOT BE PLACED WITHIN 3'-0"
OF ANY CEILING MOUNTED HVAC SUPPLY AIR DEVICE.
3. NEW FIRE ALARM DEVICES SHALL MATCH EXISTING, UNLESS NOTED
OTHERWISE. PROVIDE RE-PROGRAMMING OF SYSTEM AS REQUIRED TO
ACCOMMODATE NEW DEVICES. REVISE EXISTING ANNUNCIATOR(S) AND
GRAPHIC ZONE MAP(S) TO REFLECT PROJECT FIRE ALARM AND
ARCHITECTURAL MODIFICATIONS. UPDATE GRAPHIC ZONE MAPS AS
REQUIRED. SUBMIT TO ENGINEER AND BUILDING/FIRE DEPARTMENTS FOR
REVIEW PRIOR TO INSTALLATION.
PROJECT:
CROSSROADS
BUILDING
RENOVATION
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
OWNER:
LARAMIE COUNTY
COMMUNITY
COLLEGE
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
ISSUE:
02.19.2018 CONTRACT DOCUMENTS
DRAWING INFORMATION:
PROJECT NO:
11738.001
DRAWN BY:
BJK
CHECKED BY:
CMI
APPROVED BY:
CMI
SHEET TITLE:
ELECTRICAL
LEGENDS & NOTES
E-001
SHEET
OF
2
3
4
5
6
1
E
2
3
A
B
4
C
D
5
6
KEYNOTES
LD1 AREA OUTSIDE OF PROJECT SCOPE.
hord|coplan|macht
1331 Nineteenth Street
Denver, CO. 80202
P 303.607.0977
www.hcm2.com
CONSULTANT:
D
C
B
A
1
R
R
R
LD1
R
R
R
ER
R
R
R
ER
R
1
E
R
R
ER
R
ER
R
R
E
R
R
ER
R
R
ER
R
R
R
R
R
R
R
R
ER
ER
R
R
ER
E
E
E
R
R
R
FIRST FLOOR LIGHTING DEMOLITION PLAN
SCALE: 1/8" = 1'-0"
2
3
4
N
KEY PLAN
5
6
PROJECT:
CROSSROADS
BUILDING
RENOVATION
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
OWNER:
LARAMIE COUNTY
COMMUNITY
COLLEGE
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
ISSUE:
02.19.2018 CONTRACT DOCUMENTS
DRAWING INFORMATION:
PROJECT NO:
11738.001
DRAWN BY:
BJK
CHECKED BY:
CMI
APPROVED BY:
CMI
SHEET TITLE:
FIRST FLOOR
LIGHTING
DEMOLITION PLAN
ED-111
SHEET
OF
1
E
D
C
B
A
1
2
3
4
5
A
B
C
D
MECHANICAL
101
D3
'f'
PA-6
D3
'f'
PA-6
D3
'f'
PA-6
D3
'f'
PA-6
D3
'f'
PA-6
L3
T2
NL
PA-6
T2
PA-6
T2
L3
EM-34
EM-34
X1
NL T2
T2
EM-34
X1
VESTIBULE
EM-34
PA-4
X3
EM-34
D3 100
'f'
PA-6
T2
L1 LC5 L2
ED
PA-6
3 EM-34
X1
L3
L4
D3
'f'
NL STORAGE
PA-6
RECEPTION/WAITING
104D
L1
104A
PA-6
T2
PA-6
L6
P2
PA-6
P2
PA-6
T2
D3
'f'
PA-6
LC5 L2
PA-4
T1
L3
S1
PA-4
OFFICE
104E
PA-4
T1
L1 LC5 L2
PA-6
CONFERENCE
ROOM
L3
104B
EM-34
NL
NL
EM-34
X1
EM-34
L1 LC2 L2
D
C1
L1 LC2
L1 LC7 L2
L1 LC2 L2
T1
L2
T1
OFFICE
NL
T2
L3
L3
NL
T2
STUDY
X1 SPACE
104C
PA-4
104F
PA-4
T1
1
T1
PA-2
WOMEN'S
TOILET
114
L4
JAN.
CORR.
111
EM-34
EM-34
X2
PA-6
L6
P2
PA-6
P2
EM-34
PA-4
'c' D1
PA-6
'c' D1
PA-6
OFFICE
104M
PA-4
T1
L3
NL
EM-34
T2
PA-4
T1
L1 LC6 L2
MEN'S 112
TOILET
L1 LC2 L2
PA-4
L1 LC2 L2
L5
OFFICE
STUDY /
COMPUTER
110C
113
D
EM-34
NL
L3
L1
STUDENT
VETERANS
LOUNGE
110A
PA-2
LC6 L2
T1
L3
X1
NL
PA-6
T2
PA-6
C1
L1 LC5 L2
PA-6
L6
P2
PA-6
P2
J
'c' D1
L5
PA-6
J COMMUNITY
PA-6
CAFE
108
T2 'c' D1
'c' D1
PA-6
PA-6
T1
PA-4
OFFICE
104L
L1 LC2
EM-34
L3 NL
CORRIDOR
104K
104G
OFFICE
104H
L3
L1 LC2 L2
L2
NL
EM-34
T1
PA-4
L1
X1
X1 LC5
L2
PA-4
T1
'b'
'b'
EM-34
D
D
L1
LC2
'b'
PA-2
L2
L3
NL T2
EM-34
PA-6
L6
P2
PA-6
P2
T2
PA-6
EM-34
'a'
'a'
PA-6
P2
L2
LC2
L1
L1 LC2 L2
OFFICE
104J
SPECIALIST
OFFICE
EM-34
L3
NL
'a'
'a'
'a'
'a'
T1
SVA
'a'
'a'
OFFICE
'b' 110B
'a'
'a'
L5 J
J L5
'a'
'a'
L1 LC5 L2
PA-4
T1
105B
L1 LC2 L2
T1
'a'
'b'
'a'
PA-2
C1 D2
'a'
L2
CONF
ROOM'a'
'a' 109
L1 LC4
'a'
'a'
'a'
'a'
'a'
L3
NLEM-34
'b'
'b'
'b'
D'b' D'a'
T2
PA-6
T2
PA-6
T2
PA-6
T2
PA-6
T2
PA-6
L1 LC5 L2
EM-34
X1
COLLABORATION
'a'
'a'
PA-4
'a'
D'b' D'a'
L5
L3 NL
EM-34 'a'
L5
L1 LC3 L2
J
STORAGE
105C
J
S1
PA-4
PA-4
S1
LC3
L1
L2
103
'b'
'b'
'b'
L3
NL
EM-34
L1 LC5 L2
T1
PA-2
L3
NL
EM-34
EM-34 L3
EM-34
NL
X1
'b'
'b'
PA-2
P2
'b'
L3
NL EM-34
X1
'b'
L3
NL
EM-34
L1 LC5 L2
T1
PA-4
L3
NL
EM-34
L3
T1
NL
EM-34
'b'
'b'
'b'
L3
T1
NL
EM-34
FIRST FLOOR LIGHTING PLAN
SCALE: 1/8" = 1'-0"
2
3
4
5
6
KEYNOTES
L1 OCCUPANCY SENSORS AND TIMECLOCK SWITCHING SHALL BE
PRICED AS ADD ALTERNATE #3.
L2 IF ADD ALTERNATE #3 IS NOT SELECTED, CONTRACTOR SHALL
PROVIDE LOCAL DIMMERS/SWITCHES AS SHOWN WITH A MINIMUM
OF ONE CONTROL LOCATION PER SPACE.
L3 FIXTURE TO REMAIN ON AS A SECURITY LIGHT. BYPASS LOCAL
SWITCHES AND CONTACTORS.
L4 AREA OUTSIDE OF PROJECT SCOPE.
L5 SPECIALTY LIGHTING. REFER TO ARCHITECTURAL PLANS FOR
FURTHER DETAILS. PROVIDE A SEPARATE SWITCH AT A LOCATION
DICTATED BY OWNER/ARCHITECT.
L6 FIXTURE TO BE INSTALLED ABOVE CEILING. ADJUST PENDANT
LENGTH SO FIXTURE IS JUST ABOVE OPEN GRATING.
hord|coplan|macht
1331 Nineteenth Street
Denver, CO. 80202
P 303.607.0977
www.hcm2.com
CONSULTANT:
PROJECT:
CROSSROADS
BUILDING
RENOVATION
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
OWNER:
LARAMIE COUNTY
COMMUNITY
COLLEGE
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
ISSUE:
02.19.2018 CONTRACT DOCUMENTS
N
KEY PLAN
6
DRAWING INFORMATION:
PROJECT NO:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET TITLE:
11738.001
BJK
CMI
CMI
FIRST FLOOR
LIGHTING PLAN
E-111
SHEET
OF
1
E
D
C
B
A
1
2
3
A
B
4
C
D
5
6
KEYNOTES
ED1 PANEL LA TO BE REPLACED. PULL BACK CIRCUITS AS NEEDED TO
REMOVE PANEL AND INSTALL NEW EQUIPMENT.
ED2 NO POWER SCOPE IN AREA NOTED.
ED3 REMOVE ALL EXISTING FIRE ALARM DEVICES IN SCOPE AREA.
RACEWAY AND CABLE MAY BE REUSED AS AVAILABLE.
ED4 TRANSFORMER TO BE REPLACED.
hord|coplan|macht
1331 Nineteenth Street
Denver, CO. 80202
P 303.607.0977
www.hcm2.com
CONSULTANT:
E
E
ER
ER
R
ED3
R
ED2
R
E
WP
R
R
ER
R
1
R
E
R
R
R
R
ER
ER
ER
R
E
R
E
R
R
ER
R
ER
R
R
ER
R
R
ER
ER
UP
R
R
R
ED3
R
R
+65"
R
R
AC
R
AC
AC
R
ER
ER
R
ER
ER
R
ED3
R
R
AC
R
AC
+65"
R
R
P
ER
UP
ER
R
R
ER
ER
ER
ER
R
ER
R
ED4
T45
ER
LB
ER
ED1 LA
ER
PA
ED2
ED3
ED2
ED3
ER
ER
R
FIRST FLOOR POWER/FA DEMOLITION PLAN
SCALE: 1/8" = 1'-0"
2
3
4
N
KEY PLAN
5
6
PROJECT:
CROSSROADS
BUILDING
RENOVATION
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
OWNER:
LARAMIE COUNTY
COMMUNITY
COLLEGE
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
ISSUE:
02.19.2018 CONTRACT DOCUMENTS
DRAWING INFORMATION:
PROJECT NO:
11738.001
DRAWN BY:
BJK
CHECKED BY:
CMI
APPROVED BY:
CMI
SHEET TITLE:
FIRST FLOOR POWER
DEMOLITION PLAN
ED-121
SHEET
OF
1
E
D
C
B
A
1
2
3
4
5
A
B
C
D
FIRE
SERVICE
102A
FOOD
PANTRY
102
AC USB
LA-45 LA-45
E9
USB AC
LA-45 LA-45
E9
MECHANICAL
101
LA-50,52
HWP
E12
3
M TO
LA-45
VESTIBULE
100
LA-2
AC
E9 LA-9
USB
RECEPTION/WAITING
WP
3
LA-48
104A
AC
E9 LA-9
USB
E9
LA-2
USB
AC
STORAGE
104D
LA-7
OFFICE
LA-65 LA-20
CONFERENCE
LA-65 ROOM
LA-2
104E
USB
104B LA-20
LA-2
J E1
WOMEN'S
1
LA-60
E2
TOILET
114
E11 LA-9
E11 LA-9
E10 J
E9
LA-65 LA-20
+65"
E11
LA-63
LA-20
E2
LA-9 J
E1
E2
J
LA-63 LA-20
E1
+65"
LA-2
STUDY
SPACE
104C
OFFICE
104F
LA-4
LA-72
LA-72
CORR.
LA-65 LA-65
E13 LA-54
OFFICE
104M
LA-4
JAN.
111
LA-10
E11
112
E13 LA-56
OFFICE
LA-60
LA-60
LA-60
STUDY /
COMPUTER
LA-72 110C LA-72
MEN'S
TOILET
113
EWH
SU
1
LA-69
COMMUNITY
CAFE
108
E4
OFFICE
104L
LA-10
LA-2
104G
OFFICE
104H
STUDENT
VETERANS
+65"
LA-67
AC
USB
COLLABORATION
LA-8
LA-11
LOUNGE
E9
103
J
LA-34
PM
E6
110A
LA-18
J
PM E6
LA-34
LA-44
E4
LA-59 LA-55
E14 E14
CORRIDOR
104K
E3
LA-57
LA-3
LA-16
AC
AC
LA-49
LA-49
LA-49
+65"
LA-49
LA-67 LA-49
AC
LA-58
SVA
OFFICE
110B
LA-16
LA-40
LA-66
E11
E2
LA-66
E11
J
LA-40
LA-66
E11
E2
LA-49
CONF
ROOM
109
LA-49
E10
LA-40
LA-40
LA-40
E2
LA-40
LA-40
J
LA-40 LA-12
E2
J
E2
J
E9
LA-12
USB AC
LA-33
E11
LA-33
E11
E2
E2
E11
LA-22
E11
LA-22
OFFICE
104J
E5
LA-51 LA-51
COMPUTER
STATIONS
E5
107
LA-6
IT/HELP
DESK
105A
SPECIALIST
OFFICE
105B
LA-3
LA-35
LA-35
STORAGE
E5
E3
105C
T
E15
LA-13
L5-30R
LA-35
LA-35
LA-5
LA-5
E3
2
LA-5
LA-15
TO LA-53
1
LA-47
T75
E8
ELEC.
106
T
LB
LA E7
PA
E1
UP
UP
EF L5-30R
E15
2
LA-64
AC
USB E9
LA-43
AC
E9 USB
LA-43
LA-43
LA-43
WP
+65"
+65"
WP
FIRST FLOOR POWER PLAN
SCALE: 1/8" = 1'-0"
2
3
4
5
6
KEYNOTES
E1 RE-USE EXISTING RECEPTACLE BOX LOCATION TO TRANSITION TO
NEW SURFACE RACEWAY.
E2 LOW PROFILE SURFACE RACEWAY TO BE MOUNTED OVER FLOOR
COVERING. SECURE PER MANUFACTURERS REQUIREMENTS.
PROVIDE CONCEALED TRANSITIONS AT WALL. LEGRAND OFR
SERIES OR EQUAL.
E3 DEDICATED RECEPTACLE FOR PRINTER. COORDINATE ROUGH IN
WITH CASEWORK AND EQUIPMENT CONNECTION POINT.
E4 DEDICATED RECEPTACLE FOR FUTURE USE.
E5 TIMBER POLE WITH WIRING CHANNEL. REFER TO ARCHITECTURAL
PLANS FOR FURTHER DETAILS.
E6 HORIZONTAL PLUGMOLD INSTALLED ALONG CASEWORK. PROVIDE
DUPLEX RECEPTACLE AT EACH COMPUTER STATION. RACEWAY
SHALL HAVE SEPARATE CHANNEL FOR DATA CABLING.
E7 RECONNECT EXISTING CIRCUITS TO NEW PANELBOARD. REFER TO
PANEL SCHEDULE FOR ADDITIONAL INFORMATION.
E8 PROVIDE NEW K-RATED TRANSFORMER. INSTALL ON DOUBLE
DEFLECTION NEOPRENE ISOLATORS.
E9 PROVIDE DEVICE WITH INTEGRAL USB CHARGER. LEGRAND #TM8
OR EQUAL.
E10 PROVIDE FLOOR BOX FOR A/V CONNECTIONS. REFER TO
TECHNOLOGY PLANS FOR DETAILS.
E11 DOUBLE SIDED FLOOR BOX TO HAVE PLATES FOR DUPLEX
RECEPTACLE ON FRONT AND SINGLE DATA JACK ON BACK.
E12 PRICE EQUIPMENT AND CONNECTIONS WITH ADD ALTERNATE #1.
E13 DEDICATED RECEPTACLE FOR MICROWAVE. COORDINATE ROUGH
IN WITH CASEWORK AND EQUIPMENT CONNECTION POINT.
E14 DEDICATED RECEPTACLE FOR VENDING MACHINE. COORDINATE
ROUGH IN WITH CASEWORK AND EQUIPMENT CONNECTION POINT.
E15 LINE VOLTAGE THERMOSTAT PROVIDED WITH EF-2. CONNECT IN
PARALLEL WITH OTHER STAT NOTED TO ENERGIZE FAN WHEN
ROOM TEMPERATURE EXCEEDS SET POINT. REFER TO MECHANICAL
PLANS FOR FURTHER DETAILS.
hord|coplan|macht
1331 Nineteenth Street
Denver, CO. 80202
P 303.607.0977
www.hcm2.com
CONSULTANT:
PROJECT:
CROSSROADS
BUILDING
RENOVATION
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
OWNER:
LARAMIE COUNTY
COMMUNITY
COLLEGE
1400 EAST COLLEGE DRIVE
CHEYENNE, WY 82007
ISSUE:
02.19.2018 CONTRACT DOCUMENTS
N
KEY PLAN
6
DRAWING INFORMATION:
PROJECT NO:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET TITLE:
11738.001
BJK
CMI
CMI
FIRST FLOOR POWER
PLAN
E-121
SHEET
OF

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Opportunity History Complete View Original Synopsis Presolicitation Mar 29, 2019 5:25 pm Changed

Department of Transportation

Bid Due: 5/29/2019

Opportunity History Complete View Original Synopsis Presolicitation Apr 17, 2019 7:22 pm Changed

Department of Agriculture

Bid Due: 6/06/2019

Opportunity History Original Synopsis Mar 29, 2019 5:25 pm Solicitation Number : 69056719R000013

Department of Transportation

Opportunity History Original Synopsis Apr 17, 2019 7:22 pm Solicitation Number : 1282BH19R0005

Department of Agriculture