Construction Manager-at-Risk Solicitations - EDS Substations and Switchgear Upgrade
| Agency: | University of North Carolina |
|---|---|
| State: | North Carolina |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Sep 8, 2026 |
| Due Date: | Sep 29, 2026 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
By Gary Wilhelm
Zoom link in Project Brief, see below.
Closing Date 09/29/2026Project Budget$14,500,000.00Project DescriptionThis project serves to enhance the University’s response to unplanned electrical distribution outages amongst the three substations that supply UNC’s campus. The three substations serving the campus are Cameron Avenue, Manning, and South (see Attachment). The planned upgrades will allow the University to restore power more quickly and improve the resiliency across campus.
This project will require creating approximately 2,500 linear feet of new duct bank and primary cabling arrangements totaling approximately 16,500 linear feet, along with switchgear and smart protective relays that communicate with the Electrical Distribution Systems SCADA system.
A secondary goal of this project is to replace two General Electric 15 kV Powervac Vacuum Switchgears with two Arc Flash Resistant, 15 kV, 3000 Amp continuous, and 40 kA interrupting rating Switchgears located at the Cameron Substation. These replacement switchgears shall maintain hardwiring controls integration with the Cogeneration Systems Plant and communication controls interface with the Electrical Distribution Systems SCADA system.
Project Brief (opens PDF in new window)
Submit To:
UNC-Chapel Hill
Facilities Planning & Design
Stephen Moorefield, PE
Giles Horney Building
103 Airport Dr
Chapel Hill, NC 27599
Advertisement Type: Construction Manager-at-Risk Solicitations
See Also
Solicitation Number: 487-7th and College Street Parking Deck Project Title: ADVERTISEMENT TO BID
State Government of North Carolina
Due by 11/19/2026
Institution NC School of Science and Math Institution URL for Additional Information about
University of North Carolina System
Due by 11/17/2026
Solicitation Number: 367-OC5491 Project Title: Orange Grove Road Transit Access Sidewalk Project Description:
State Government of North Carolina
Due by 12/07/2026
Request for Qualifications: 26-0250 Middle Creek Greenway Pedestrian Hybrid Beacon The Town of
Town of Holly Springs
Due by 12/01/2026