656-22-341 Conduct Substation Upgrade
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Minnesota |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) |
| Posted Date: | Mar 4, 2026 |
| Due Date: | May 1, 2026 |
| Solicitation No: | 36C26326B0024 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Presolicitation (Original)
- Original Published Date: Mar 04, 2026 04:03 pm CST
- Original Response Date: May 01, 2026 10:00 am CDT
- Inactive Policy: Manual
- Original Inactive Date: Dec 31, 2026
-
Initiative:
- None
- Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Product Service Code: Y1NZ - CONSTRUCTION OF OTHER UTILITIES
-
NAICS Code:
- 238210 - Electrical Contractors and Other Wiring Installation Contractors
-
Place of Performance:
Saint Cloud , MN 56303USA
The Contractor shall furnish all labor, materials, tools and equipment required to:
- Remove and replace two large 5000KVA utility grade transformers with two 6000 KVA utility grade transformers.
- Remove and replace a total of 16 smaller medium voltage transformers in the range of 30 KVA to 750 KVA.
- Provide passive, anti-ram rated bollards in accordance with ASTM F2656 crash rating requirements (minimum M30/P1 or as directed by VA), installed per Specification Section 34 71 13. Bollards shall be placed a minimum of 3 feet from transformer pads, spaced no more than 5 feet apart, and removable where located within electrical working clearances, designed per project drawings.
- Replace transformer pads, where required, with new pads meeting 4000 psi concrete strength and reinforcement per EK501 detail in the drawings.
All work completed in accordance with the specifications and contract drawings.
Work includes, but is not limited to:
- Demolition and removal of items noted in the Contract Documents including but not limited to existing transformers and concrete as required.
- Contractor shall remove from the VA site and dispose of all equipment and materials not scheduled to be reused.
- No asbestos and/or lead finds are anticipated.
- Electrical, Landscape, Site Concrete are trades expected to be needed as part of this project.
- Contractor to furnish all equipment.
- New construction consists of but is not limited to: Substation area and the vicinity of each transformer being replaced.
- Provide anti-ram rated bollards.POP 886
- 316 Robert Street N Suite 506
- Saint Paul , MN 55101
- USA
- Dwayne Brauch
- dwayne.brauch@va.gov
- Phone Number 6512933039
- Mar 04, 2026 04:03 pm CSTPresolicitation (Original)
Related Document
| Apr 6, 2026 | [Solicitation (Original)] 656-22-341 Conduct Substation Upgrade |
See Also
26-49 Construction Manager Agency - Fire Station 2 The City of Bloomington is
City of Bloomington
Due by 9/29/2026
Location Details City: Hanover County: Wright State/Province: MN Project Details Online Bidding: Available
WSB
Due by 9/29/2026
Bid Title: 26-05 - Fernbrook Lane Improvements Phase 1 Category: General bid opportunities
City of Maple Grove
Due by 10/31/2026
Event Name Business Unit Event ID Event Format Event Type COM Event Type
City of Minneapolis
Due by 9/30/2026