CIP Project #333, New Fire Station #2

Agency: City of Santa Fe
State: New Mexico
Type of Government: State & Local
NAICS Category:
  • 236220 - Commercial and Institutional Building Construction
Posted Date: Oct 11, 2019
Due Date: Nov 5, 2019
Bid Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Vendor Self-Service

CIP Project #333, New Fire Station #2
Bid Number: 20/05/RFQ
Status: Open
Close Date: 11/5/2019 2:00 PM
Project Manager:
Jason Kluck
505.955-5937
Proposal Submission Information:
See Bid/RFP documents for additional submission details.
City of Santa Fe Purchasing Office 200 Lincoln Ave., Room 122 Santa Fe, NM 87505

The project scope of work includes, but is not limited to, the comprehensive construction of an approximately

14,000 gross interior square foot fire station (with approximately 2,100 square feet of exterior portales) located at

5750 Alameda Frontage Road in Santa Fe, New Mexico (near the intersection of Hwy. 599 & S. Meadows Road)

and consisting of a three bay drive-through apparatus room and auxiliary functions, multi-function tower for

training and a public safety radio system, living quarters, bunker and locker rooms, laundries, bathrooms, kitchen,

dining room, dayroom, fitness room, study and exterior portals. The project includes construction of utilities

infrastructure INCLUDING construction and/or coordination of construction of source extensions to the virgin

project site (water, sewer, power, natural gas, telecom), earthwork, access road extension and driveways, parking

lots, vehicle pads and hardscaping, curb and gutter, sidewalks and walkways, exterior lighting, perimeter fencing

and yard walls, automated gates, all utilities, irrigation system, landscaping, furnishings and building infrastructure

required for ITT systems, Public Safety Radio system and Pager system infrastructure, but excluding installation of

Tel/Data equipment, wiring and outlets, Public Safety radio system, ITT Point-to-Point equipment and Radio Pager

system.

Related Documents:
20/05/RFQ [313.6 K]

Attachment Preview

REQUEST FOR QUALIFICATIONS
The City of Santa Fe is requesting submittal of qualifications by Prime Contractors licensed under NMRLD
General Construction Classification GB-98 for consideration to bid on the construction of CIP PROJECT #333, NEW
FIRE STATION #2, RFQ # ‘20/05/RFQ.
INITIAL INFORMATION
Responses to this Request for Qualification (RFQ) from Contractors will be received by the City of Santa Fe in a
sealed envelope to the City of Santa Fe Purchasing Office at 200 Lincoln Avenue, Santa Fe, NM 87504-0909,
(505)955-6432, until 2:00 P.M. local prevailing time, Tuesday, November 5, 2019. Any qualifications received
after the deadline will not be considered. Failure of a bidder to become prequalified under this RFQ will render
non-responsive any construction bid submitted by them for this project and the bid will be rejected and remain
unopened.
The City will select contractors qualified to bid on the project described below. Criteria for qualification will be
based on the items requested below. Failure to submit any one of the items below may result in disqualification.
The criteria listed below will be assessed against a maximum possible point value as noted. Contractors who meet
90% of the total possible 100 points will be determined as qualified to bid on construction. At the City’s
discretion, the Invitation to Bid (ITB) will directly follow the City’s prequalification of contractors. The City
reserves the right extend the release of the ITB up to six (6) months after selection of pre-qualified bidders and to
cancel the procurement without cause at any time prior to Award of Contract. Local and State preferences will be
applicable to this bid.
SCOPE OF WORK
The project scope of work includes, but is not limited to, the comprehensive construction of an approximately
14,000 gross interior square foot fire station (with approximately 2,100 square feet of exterior portales) located at
5750 Alameda Frontage Road in Santa Fe, New Mexico (near the intersection of Hwy. 599 & S. Meadows Road)
and consisting of a three bay drive-through apparatus room and auxiliary functions, multi-function tower for
training and a public safety radio system, living quarters, bunker and locker rooms, laundries, bathrooms, kitchen,
dining room, dayroom, fitness room, study and exterior portals. The project includes construction of utilities
infrastructure INCLUDING construction and/or coordination of construction of source extensions to the virgin
project site (water, sewer, power, natural gas, telecom), earthwork, access road extension and driveways, parking
lots, vehicle pads and hardscaping, curb and gutter, sidewalks and walkways, exterior lighting, perimeter fencing
and yard walls, automated gates, all utilities, irrigation system, landscaping, furnishings and building infrastructure
required for ITT systems, Public Safety Radio system and Pager system infrastructure, but excluding installation of
Tel/Data equipment, wiring and outlets, Public Safety radio system, ITT Point-to-Point equipment and Radio Pager
system.
The principal building materials and systems are anticipated as follows:
Asphalt roads and driveways with concrete curb & gutter
Reinforced concrete and concrete open grid paver exterior flatwork,
ICF/cast reinforced concrete and CMU exterior and partial interior walls, high performance envelope
Exposed integrally colored and gray concrete slab floors (with carpet and sheet goods flooring in select
locations)
Glulam and composite wooden structural frame
Wooden interior frame with drywall and low/no VOC paint or tile finish
Three coat cementitious stucco with synthetic color coat exterior finish
Sloped standing seam metal and mechanically fastened poly membrane roof systems
Aluminum and metal clad wood windows and exterior doors
Hollow metal and solid core wood interior doors
Metal lockers, stainless steel and synthetic stone countertops with melamine type casework
HVAC package unit forced air system with enhanced indoor air quality
Gas hot water boilers, low flow plumbing fixtures, fire suppression sprinkler system
Infrastructure for grid-tie PV
High efficiency LED lighting and tube skylights
Comprehensive furnishings and equipment package
Drought tolerant landscaping with passive storm water aided irrigation and possible greywater reuse
Code required landscaping with temporary domestic water automated irrigation system
SUBMITTALS
Responses shall be (1) original and six (6) copies in a sealed envelope.
Submit the following pre-requisites: (Yes = qualifies for evaluation / No = disqualification)
A. Contractor’s certification of licensure as required for this project.
B. Contractor’s certification of registration with the New Mexico Department of Workforce Solutions (State
Labor department).
C. Letter from Contractor’s surety company certifying bonding capacity of at least $8,000,000.00
D. Statement of insurance coverage from Contractor’s insurance company.
Type of insurance or bond
Performance & Payment Bonds
Commercial General Liability
Automobile Liability
Workers Compensation
Workers
Limit of liability or bond amount ($0.00)
100% of the Contract amount
$1,000,000 per occurrence, $2,000,000 general
aggregate
$500,000 combined single limit
$100,000 each accident, $100,000 disease, each
employee
$500,000 disease, policy limit
E. Letter of Reference from Contractor’s bank
F. Statement of Bidder’s Qualifications (form attached)
G. Complete response to the qualification criteria below
Below is a list of the criteria that must be included within the qualifications submittal (8 ½” x 11” report format—
bound or stapled, and indexed). The maximum point value of each item (if applicable) is also listed.
Criteria: The following will be reviewed toward qualification. To qualify to bid, a Contractor must meet overall
point value of 90 points.
1. Minimum of five successfully completed public or commercial projects that meet the following:
a. similar project components of large-scale mass grading/site work, roads, parking, utilities, building
and landscaping components
b. within the past five years,
c. each project being a minimum $5 million contract amount,
d. one of the five projects having a minimum $10 million contract amount,
e. three of which (including item d) the proposing contractor was the prime contractor managing
multiple sub-contractors.
For each project, provide the project name, address, detailed description of work, original contract amount,
final paid contract amount, original contract completion date, actual completion date, and owner references,
including name of owner’s project manager and their current phone number. (30 points)
2. Provide resumes for Contractor’s Project Manager and Project Superintendent. Resumes shall demonstrate
experience on multiple projects of similar scale and complexity of the proposed project (15 points)
3. Provide a safety record for the past five years: The safety record provided must specify for each year the total
number of employees, the number of deaths, number of injuries, total number of cases with days away from
work, or alternatively, provide copies of OSHA’s form 300A for each of the last 5 years. (15 points)
4. Provide examples of the Contractor’s management documentation regularly used on projects of similar scale
and complexity. If digital process is used, describe the process and how it is managed. (10 points)
a. Project CPM or Gantt charts for project schedule tracking.
b. Weekly progress meeting notes.
c. RFI and Submittals tracking process and logs.
5. In the past ten (10) years has the company been assessed liquidation damages on any State, Local, or Federal
projects (include the project name, amount of days, dollar amount assessed and project owner)? (5 points)
6. In the past ten (10) years has the company filed a formal claim against any State, Local, or Federal agency? If
yes, include project name, claim amount, settlement amount. (5 points)
7. In the past ten (10) years has the company been denied pre-qualification by any State, Local, or Federal
agency? If yes, indicate the agency and provide a detailed explanation. (5 points)
8. Statement of any litigation, past or present; indicate the outcome of litigation. (5 points)
9. Statement of commitment to bid, if selected as a pre-qualified contractor. (10 points)
LAWS & REGULATIONS
The Contractor’s attention is directed to the fact that applicable Federal Laws, State Laws, Municipal Ordinances,
and all rules and regulations of all authorities having jurisdiction over said item shall apply to the RFQ and will
apply to the Contractor that is selected. The laws will be deemed to be included in the contract to be negotiated
with the successful proponent, the same as though herein written out in full.
The City of Santa Fe is an Equal Opportunity Employer and all qualified applicants will receive consideration for
employment without regard to race, color, religion, sex, sexual orientation or national origin. The successful
proponent will be required to conform to the Equal Opportunity Employment regulations. State wage rates will
apply.
CONTACT INFORMATION
Any questions regarding this RFQ shall be directed to the City of Santa Fe Purchasing Office. Phone 505-955-6432,
E-mail: fadunaway@santafenm.gov.
STATEMENT OF BIDDER’S QUALIFICATIONS
Instructions: All questions must be answered, and the data given must be clear and comprehensive. This statement must be notarized. If
necessary, questions may be answered on separate attached sheets. The Bidder may submit any additional information desired.
1.
Name of Bidder:
2.
Permanent main office address:
3.
Date organized:
4.
If a corporation, provide type and location of incorporation:
5.
How many years has the contracting company been engaged in the contracting business under the present firm or trade name?
6.
Provide a summary of current contracts (schedule these, showing amount of each Contract and the appropriate anticipated dates
of completion):
7.
Describe the general character of work performed by the contracting company:
8.
Has the contracting company ever failed to complete any work as awarded?
If so, where and why?
9.
Has the contracting company ever defaulted on a contract?
If so, where and why?
10.
List the major relevant projects recently completed by the contracting company, stating the approximate cost for each, and the
month and year completed:
11.
List applicable major equipment owned by the contracting company available for this contract:
12.
Describe experience in construction work similar in scope to this project:
13.
Provide the background and experience of the principal members of your organization, including the officers:
14.
Will the contracting company, upon request, provide a detailed financial statement and furnish any other information that may
be required by the Owner?
15.
The undersigned authorizes and requests any person, firm, or corporation to furnish any information requested by the Owner in
verification of the recitals comprising this Statement of Bidder Qualifications.
Dated at _____________________________________________________________________________________________
this ____________________________ day of __________________________________, 20_____.
Bidder: __________________________________
By: _____________________________________
Title: ____________________________________
STATE OF NEW MEXICO
)
)ss
COUNTY OF
)
_____________________________________________________________________________, being duly sworn, deposes and says that:
He/She is ________________________________________________________________________________________________________
of ______________________________________________________________________________________________________________
(Name of Organization)
and that the answers to the foregoing questions and all statements therein contained are true and correct.
Subscribed and sworn to before me this ____________ day of _________________, 20___.
____________________________________________
Notary Public
My Commission expires: _______________________

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Opportunity History Complete View Original Synopsis Presolicitation Aug 02, 2019 5:21 pm Changed

International Boundary and Water Commission

Opportunity History Original Synopsis Oct 24, 2019 4:25 pm Solicitation Number : 140F0220R0004

Department of the Interior

Bid Due: 11/25/2019

no. nigp code type name due date 20-0021 90930 BID Dona Ana Fire

Doña Ana County

Bid Due: 12/05/2019

Opportunity History Original Synopsis Sep 28, 2019 10:04 am Solicitation Number : 191BWC19B0002

International Boundary and Water Commission