C1DA--402-25-008 Repair Condensate Pump Room Roof
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | May 27, 2025 |
| Due Date: | Jun 27, 2025 |
| Solicitation No: | 36C24125R0058 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
Follow
Active
Contract Opportunity
Notice ID
36C24125R0058
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
241-NETWORK CONTRACT OFFICE 01 (36C241)
General Information
Classification
Description
Contact Information
History
- Contract Opportunity Type: Special Notice (Original)
- Original Published Date: May 27, 2025 02:46 pm EDT
- Original Response Date: Jun 27, 2025 04:30 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Sep 25, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: C1DA - ARCHITECT AND ENGINEERING- CONSTRUCTION: HOSPITALS AND INFIRMARIES
-
NAICS Code:
- 541330 - Engineering Services
-
Place of Performance:
Request For Qualifications Statements (SF 330)
General Project Description:
Project Number: 402-25-008
Project Title: A-E Repair Condensate Pump Room Roof
Location of Project: VA Maine Healthcare System (VAMC Togus), Augusta, Maine 04330
A/E Type A&B Services (also known as Design Phase) for this design project includes site visits, field investigation, studies and user interviews to prepare drawings, specifications and cost estimates for all facets of work and disciplines/trades to repair condensate pump room roof located on the Togus campus. This project will repair the deteriorating condensate pump room roof in the basement of B201. The A/E must consider the need for all condensate pumps to remain operational during the construction period. This project will consist of concrete testing and design for temporary shoring, abatement (if required), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant. The existing ceiling supports multiple pipes and electrical conduits, lights, etc. The design package should include detailed plans on how to temporarily support all existing utilities. If disconnection is required, the A/E must determine the source of energy, existing isolation locations, and impact to facility when isolated. The A/E is to provide a final load rating for the roof once repairs are complete. The design will include drawings showing ICRA required construction barriers, properly sized negative air machines, as well as duct routing for exhausting air. Additionally, the A/E shall prepare all required National Environmental Policy Act (NEPA) analysis and Environmental Assessment reports and documentation for any improvements made as part of this project.
NAICS and Set-Aside Information:
This procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has an SBA size standard of $25.5 million in average revenue. This procurement is a total set-aside for verified Small Businesses (SB).
Key Dates:
Period of Performance: 120 calendar days.
Questions Due: 06/06/2025 4:30 PM EST.
SF 330 Package Due: 06/27/2025 4:30 PM EST.
Instructions:
See attached Request for Qualification Statement (SF330s) for submission requirements.
General Project Description:
Project Number: 402-25-008
Project Title: A-E Repair Condensate Pump Room Roof
Location of Project: VA Maine Healthcare System (VAMC Togus), Augusta, Maine 04330
A/E Type A&B Services (also known as Design Phase) for this design project includes site visits, field investigation, studies and user interviews to prepare drawings, specifications and cost estimates for all facets of work and disciplines/trades to repair condensate pump room roof located on the Togus campus. This project will repair the deteriorating condensate pump room roof in the basement of B201. The A/E must consider the need for all condensate pumps to remain operational during the construction period. This project will consist of concrete testing and design for temporary shoring, abatement (if required), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant. The existing ceiling supports multiple pipes and electrical conduits, lights, etc. The design package should include detailed plans on how to temporarily support all existing utilities. If disconnection is required, the A/E must determine the source of energy, existing isolation locations, and impact to facility when isolated. The A/E is to provide a final load rating for the roof once repairs are complete. The design will include drawings showing ICRA required construction barriers, properly sized negative air machines, as well as duct routing for exhausting air. Additionally, the A/E shall prepare all required National Environmental Policy Act (NEPA) analysis and Environmental Assessment reports and documentation for any improvements made as part of this project.
NAICS and Set-Aside Information:
This procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has an SBA size standard of $25.5 million in average revenue. This procurement is a total set-aside for verified Small Businesses (SB).
Key Dates:
Period of Performance: 120 calendar days.
Questions Due: 06/06/2025 4:30 PM EST.
SF 330 Package Due: 06/27/2025 4:30 PM EST.
Instructions:
See attached Request for Qualification Statement (SF330s) for submission requirements.
Attachments/Links
Contracting Office Address
- ONE VA CENTER
- TOGUS , ME 04330
- USA
Primary Point of Contact
- Andrew Merical
- Andrew.Merical@va.gov
- Phone Number 401-273-7100
Secondary Point of Contact
- May 27, 2025 02:46 pm EDTSpecial Notice (Original)
Related Document
| Jan 27, 2025 | [Sources Sought (Original)] C1DA--A-E Repair Condensate Pump Room Roof, 402-25-008 |
Get Government Bids Like This by Email
Receive daily bid alerts that match your keywords, business categories, and target regions.
See Also
Follow 657A4-26-125 Conduct Roof Deck Assessment Building 8 ME FY27 NRM Active Contract
VETERANS AFFAIRS, DEPARTMENT OF
Due by 9/23/2026
Follow C--Defense Threat Reduction Agency (DTRA) and Defense Nuclear Weapons School (DNWS Active
INTERIOR, DEPARTMENT OF THE
Due by 9/26/2026
Follow Encroachment Management Implementation and Mission Readiness, Sustainment, and Compatibility Services AE IDIQ,
DEPT OF DEFENSE
Due by 10/29/2026
Follow Notice of Consolidation Determinations and Findings - $49.9M Civil Works MATOC Active
DEPT OF DEFENSE
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.