4210--36C242-25-AP-2049 | 528-25-2-6087-0027 Brand name or Equal Bauer Unicus 4S/25H-E3 6000 PSI Fire Edition Compressor / Bath VAMC Fire Department
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | New York |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Mar 5, 2025 |
| Due Date: | Mar 12, 2025 |
| Solicitation No: | 36C24225Q0414 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Mar 05, 2025 02:17 pm EST
- Original Response Date: Mar 12, 2025 12:00 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Jun 19, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 4210 - FIRE FIGHTING EQUIPMENT
-
NAICS Code:
- 333912 - Air and Gas Compressor Manufacturing
-
Place of Performance:
Bath VA Medical Center 76 Veterans Avenue Bath , NY 14810USA
As of 02/26/2025 1. Contracting Officer s Representative (COR). .
Name:
Mark LaBarr
Section:
Logistics
Address:
76 Veterans Avenue, Bath NY 14810
Phone Number:
607-664-4877
Fax Number:
E-Mail Address:
Mark.LaBarr@va.gov
2. Contract Title.
Brand Name or Equal: Bauer UNICUS 4/S25H-E3 N1 6000 PSI Compressor.
3. Background.
The Bath VA Medical Center Fire Department relies on a high-pressure air compressor to fill self-contained breathing apparatus (SCBA) cylinders, which are essential for firefighter safety during emergency response operations. The current compressor has reached the manufacture s end-of-life, meaning it is outdated, and increasingly difficult to maintain.
4. Scope.
The purpose of this Statement of Work (SOW) is to procure and install a BAUER UNICUS 4S/25H-E3 N1 6000 PSI Compressor, Fire Edition or an equal unit that meets or exceeds the specified technical and performance requirements, for the Bath VA Medical Center Fire Department. This unit will replace the current, outdated compressor, which has reached the manufacturer s end-of-life and received multiple work orders for repairs. The new system will ensure reliable and efficient high-pressure air compression for critical fire department operations.
5. Requirements.
5.1 Equipment Specifications.
Compressor Model: Fire Edition BAUER UNICUS 4S/25H-E3 N1 6000 PSI or equal.
Edition: Fire Edition Specialized package designed to align aesthetically with fire department themes.
Operating Pressure: 6000 PSI
Horsepower: 20 HP
Charging Rate: 25.2 CFM
Filtration System: P5 Securus Filtration System or equal
Compressor Stages: 5-stage with interstage pressure gauges.
Condensate Drain System: Automatic condensate drain system with non-corrosive condensate reservoir.
Fill Station: Three-position fill station.
Storage Cylinders: Four ASME-certified cylinders mounted on the back of the unit.
Safety Features:
Low oil shutdown
High-temperature shutdown.
NEMA 4 rated electrical enclosure
Emergency stop push button
Audible alarm on safety shutdowns
Additional Features:
Electronic CO monitor Integrated real-time CO monitoring system to ensure air safety.
Remote fill connection Anables convenient remote refilling of SCBA cylinders in different locations.
5.2 Additional Specifications.
Access Doors: Snap pin technology
7 color HMI touchscreen display
NFPA 1901 2016 edition compliant 3 position containment fill station
Dimensions: 101 x 38 x 78 to fit in the only designated area
Weight: 4550 lb
Fill Station: Three-position SCBA fill station to allow for simultaneous refilling of up to three cylinders.
5.2 Installation and Service.
Installation: Vendor shall deliver and install the compressor at the Bath VA Medical Center Fire Department, ensuring full operational functionality.
Air Quality Test: A certified air quality test must be conducted at startup to ensure compliance with applicable air purity standards.
Training: The vendor shall provide hands-on training for designated fire department personnel, covering operation procedures, routine maintenance, and safety protocols.
6. Delivery & Performance Criteria.
The contractor shall complete delivery, installation, testing, and training within 6 months from the date of contract award.
7. Acceptance Criteria.
The unit shall meet all performance and specifications outlined in Section 2.
The installation must be verified for full functionality, including a successful air quality test.
Training must be completed, and designated personnel must demonstrate operational competency
8. Security.
The C&A requirements do not apply, and a Security Accreditation Package is not required.
10. Place of Performance.
Bath VA Medical Center
76 Veterans Avenue
Building 14 Fire Department
Bath, NY 14810
- 113 HOLLAND AVE
- ALBANY , NY 12208
- USA
- Corey Swinton
- Corey.Swinton@va.gov
- Mar 05, 2025 02:17 pm ESTSources Sought (Original)
Related Document
| Mar 20, 2025 | [Presolicitation (Original)] 4210--36C242-25-AP-2049 | 528-25-2-6087-0027 Brand name or Equal Bauer Unicus 4S/25H-E3 6000 PSI Fire Edition Compressor / Bath VAMC Fire Department |
| Mar 31, 2025 | [Solicitation (Original)] 4210--36C242-25-AP-2049 | 528-25-2-6087-0027 Brand name or Equal Bauer Unicus 4S/25H-E3 6000 PSI Fire Edition Compressor / Bath VAMC Fire Department |
See Also
10 Title: Supply and Deliver Fire Extinguishers to Various Port Authority facilities in
The New York State Contract Reporter
Due by 9/17/2026
Program: DCAS - Citywide Requirements Contract Industry: Goods EPIN: 85727B0002 Procurement Name: 85727B0002_BID2600064
City of New York
Due by 9/25/2026
03 Title: Lakeside Primary Connection & Equipment Note: All Bids Must Be Received
The New York State Contract Reporter
Due by 10/08/2026
31 Title: Safety Net for Targeted Populations/Sentinel Surveillance CR#: 2138030 Agency: Health, NYS
The New York State Contract Reporter