C223--523A4-26-006 Design Upgrade Elevators A/E
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Virginia |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Sep 10, 2025 |
| Due Date: | Sep 24, 2025 |
| Solicitation No: | 36C24125R0136 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Sep 10, 2025 01:48 pm EDT
- Original Response Date: Sep 24, 2025 04:00 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Nov 23, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: C223 - ARCHITECT AND ENGINEERING- GENERAL: MECHANICAL SYSTEMS
-
NAICS Code:
- 541330 - Engineering Services
-
Place of Performance:
Boston Healthcare System West Roxbury VA Medical Center West Roxbury , 02132USA
The elevator upgrades are for the following 11 elevators within Buildings 1 and 2:
Bldg. 1
Elevators 1, 2, 4, and 5 in the main lobby
Elevator 3 within EMS
Dietetics Elevator 6 at the loading dock
Bldg. 2
Service/Freight Elevator, runs from Basement to Ground Floor Loading Dock
Elevators 1, 2, and 3 in the main lobby
Vertical Transport/Dumb Waiter within SPD
The elevators to be evaluated for deficiencies include the following four (4) elevators within Building 3:
Elevators 1, 2, and 3 in the main lobby
Service Elevator, runs from Basement to Second Floor
Prior to the full upgrade of the elevators, an inspection study report and modernization survey shall be performed by an elevator design professional. The elevator design professional shall be engaged throughout the project to evaluate the specifications, determine specific compliance, and consult on installation issues. This report and the survey findings shall identify the full design needs to upgrade all elevators listed above.
For Buildings 1 and 2, the project intent includes, but is not limited to:
Upgrading machine rooms to meet current codes
Replacement of the elevator components, in accordance with VA standards, would include, but not limited to: replace all machine room equipment, elevator ropes/cabling, controls, controllers, machines, governors, pulley systems, overall lift systems; replace or install hall position indicators and buttons; replace elevator car/cab including structural, mechanical, safety, security, communications, and comfort systems.
Perform elevator testing and acceptance in accordance with VA standards and ANSI/ASME 17.2 Practice for Inspection of Elevators, Escalators and Moving Walks (Inspectors Manual). Testing and acceptance to be performed by a Certified Qualified Elevator Inspector ASME QEI-1 using ANSI s 17.2 Checklist for Inspection and Certificate of Inspection.
Finishes
Updating signage for egress in Building 1 as the ACA addition altered egress
Wall/door/stair construction
Building systems and components (e.g., electrical [normal and emergency power], HVAC, lighting, plumbing and fixtures, fire protection, fire detection/alarm, telephone/data, access control, physical security, signage)
Fire alarm elevator recall service
HVAC systems for the elevator machine rooms and integrating with the building automaton system
Hoist way ventilation/exhaust
Roof/wall penetrations
Lead, asbestos, and PCB abatement
Patient safety features
Infection control measures
Accessibility requirements (ADA, VA Barrier Free Design Standard [PG 18-13], Architectural Barriers Act Accessibility Standards [ABAAS], Massachusetts Architectural Access Board Regulations, etc.)
ASHRAE Standard 90.1 Energy Standard for Buildings
Address considerations based on Medical Center needs and scope not identified which may be of concern
For Building 3, the project intent includes, but is not limited to:
A/E to perform thorough site inspections to document the existing elevator operation
Physically surveying all elevators, highlighting at a minimum all components noted in the section above for Buildings 1 and 2
Provide a written narrative report on the condition of all elevators and components, noting deficiencies
Provide recommendations for repair or replacement of all elevators and components, addressing the identified deficiencies
Provide a cost estimate to address repairs or replacements of all elevator and component deficiencies
The design must include a construction phasing plan that minimizes any negative effects to the normal operations of the medical center. Any proposed disruptions to existing operations must be approved by the Medical Center through the Contracting Officer, Contracting Specialist, and/or Contracting Officer s Representative/Project Engineer.
Provide for Interim Life Safety Measures (ILSM) in the design of the project.
The A/E shall have specific expertise and experience in the design and coordination of elevator modernization and equipment replacement as part of a design team. The A/E shall be the lead consultant with a vertical transportation specialist. The specialist shall be an independent and fully experienced programmer, designer, and specifier of Vertical Transport for Acute Care Hospitals and Medical Centers.
The NAICS code is 541330 and the small business size standard is $25.5 million.
Interested parties responding to this sources sought request shall submit the following information:
(1) A positive statement of your intention to submit a proposal in response to a solicitation for this project and include your firm s UEI number.
(2) Evidence your firm has experience with providing A/E Services for projects that involve a full upgrade of elevators, an inspection study report, and modernization survey performed by an elevator design professional. Â
(3) Evidence your firm has experience with providing Conceptual, Design, and Construction Period (Type A, B, and C) A/E services on an active facility providing a full upgrade to elevators in various buildings including but not limited to all associated mechanical, electrical, plumbing, fire protection and communications work.
(4) Evidence your firm has experience with upgrading elevator designs with a magnitude of construction ranging between $5,000,000 and $10,000,000 or larger in a city setting.
NCO 1 looks forward to the interest of well-qualified new entrants to contracting with the Veterans Health Administration including the interest of SB and WOSB contractors and especially responses from CVE SDVOSB/VOSB Firms. This notice is published to conduct market research to determine if there is a sufficient number of verified SDVOSB s, VOSB s, WOSB s and SB s capable of performing the requirements. All information must be submitted in sufficient detail for a decision to be made on the appropriate set-aside. Failure to submit all information requested will result in a contractor not being considered as an interested SDVOSB, VOSB, or SB concern. If adequate interest is not received this action will not be set aside.
SDVOSB or VOSB firms must be verified in the Veteran Small Business Certification (VetCert) database at https://search.certifications.sba.gov/ by the Center for Veterans Enterprises. Additionally, all firms must have an active registration in SAM at www.sam.gov.
Interested firms must submit their experience to the Contract Specialist no later than 4:00 PM EDT on 9/24/2025 via email to Alexis.Duda@va.gov
DISCLAIMER
This sources sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this is marked as proprietary and will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this notice. The Government will not pay any costs for responses submitted.
RESULTS INFORMATION: Respondents will not be notified of the results of the evaluation. Firms who fail to provide ALL the required information will not be used to make the acquisition decision, which is the purpose of this announcement.
For planning purposes, the Government intends to publish a SF330 request for qualifications for this requirement on or about 10/6/2025. The SF330 request will be issued on SAM under Contract Opportunities on www.sam.gov and firms should register electronically to receive a copy when it is issued.
- ONE VA CENTER
- TOGUS , ME 04330
- USA
- Alexis Duda
- Alexis.Duda@va.gov
- Phone Number (403) 584-4040
- Sep 10, 2025 01:48 pm EDTSources Sought (Original)
Related Document
| Oct 20, 2025 | [Special Notice (Original)] C223--523A4-26-006 Design Upgrade Elevators A/E Request for SF 330 Qualifications |
| Oct 28, 2025 | [Special Notice (Updated)] C223--523A4-26-006 Design Upgrade Elevators A/E Request for SF 330 Qualifications |
| Nov 18, 2025 | [Special Notice (Updated)] C223--523A4-26-006 Design Upgrade Elevators A/E Request for SF 330 Qualifications |
See Also
Follow C1DA--Erie VA Medical Center Engineering Services IDIQ Active Contract Opportunity Notice ID
VETERANS AFFAIRS, DEPARTMENT OF
Due by 9/18/2026
27-85-3362SH Expansion to the Hanover Center for T... Status: Open IFB 126432-1 Hanover
State Government of Virginia
Due by 9/17/2026
27-85-3362SH Expansion to the Hanover Center for T... Status: Open IFB 126432-4 Hanover
State Government of Virginia
Due by 9/17/2026
Bid Number: 26-0901-01 Bid Title: North Route 11 Corridor Study RFP Category: Engineering
Rockingham County
Due by 9/25/2026