Boiler Inspection and Repairs
| Agency: | HOMELAND SECURITY, DEPARTMENT OF |
|---|---|
| State: | Maryland |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Aug 31, 2026 |
| Due Date: | Sep 11, 2026 |
| Solicitation No: | 70LCHE26QPFB00004 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- Original Published Date: Aug 31, 2026 02:08 pm EDT
- Original Date Offers Due: Sep 11, 2026 12:00 pm EDT
- Inactive Policy: 15 days after date offers due
- Original Inactive Date: Sep 26, 2026
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: J042 - MAINT/REPAIR/REBUILD OF EQUIP- FIRE FIGHTING/RESCUE/SAFETY EQUIP; ENVIRON PROTECT EQUIP/MATLS
-
NAICS Code:
- 238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
Cheltenham , MD 20623USA
The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors.
The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers.
Bidders are responsible for verifying all site conditions and quantities prior to bid submission.
The Contractor shall provide a complete inspection and troubleshooting service, which includes:
- Submitting a detailed assessment checklist noting all deficiencies.
- Providing a line-item cost estimate to correct any identified deficiencies.
- Ensuring the inspection covers, at a minimum:
- Mounting, Isolators, and Filter Components
- Burner and Gas Train
- Breeching and Combustion Air
- Boiler Inspection and Chemical Treatment
- Fan functionality
- Sight Glass, Water Piping, Gas Piping, and associated valves
- Electrical connections, including disconnect switch and safety circuits
- Control systems, firing sequences, and interlocks
- Safety controls, flame safeguards, and low water cutout
- Pressure and temperature gauges
- Testing of the safety relief valve
- Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).
- 9000 COMMO ROAD
- CHELTENHAM , MD 20588
- USA
- Chris Dills
- chris.d.dills@fletc.dhs.gov
- Aug 31, 2026 02:08 pm EDTCombined Synopsis/Solicitation (Original)
Related Document
| Sep 2, 2026 | [Combined Synopsis/Solicitation (Updated)] Boiler Inspection and Repairs |
| Sep 4, 2026 | [Combined Synopsis/Solicitation (Updated)] Boiler Inspection and Repairs |
| Sep 9, 2026 | [Combined Synopsis/Solicitation (Updated)] Boiler Inspection and Repairs |
See Also
Follow TRS-3D /AN/SPS-75 Radar repairs/ overhaul services Active Contract Opportunity Notice ID 70Z08526RRJ001B00
HOMELAND SECURITY, DEPARTMENT OF
Due by 12/01/2026
RFQ-2027-001 TRUCK SCALE, EQUIPMENT MAINTENANCE AND REPAIR Opening Date: September 16, 2026 Opening
Howard County
Due by 9/16/2026
ID: BPM058583 Title: HVAC Preventive Maintenance Status: Open Due / Close Date: 9/17/2026
State Government of Maryland
Due by 9/17/2026
ID: BPM058563 Title: Cannabis Incubator Facility Operator Status: Open Due / Close Date:
State Government of Maryland
Due by 9/30/2026