Bid #25-02 District Office Enhancement Project Addendum No. 1

Agency: Oxnard School District
State: California
Type of Government: State & Local
NAICS Category:
  • 236220 - Commercial and Institutional Building Construction
Posted Date: Dec 4, 2025
Due Date: Dec 8, 2025
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
  • Addendum No. 1 - 12-03-2025

    Bid #25-02 District Office Enhancement Project

  • Attachment Preview

    APPLICABLE CODE: 2022 CBC
    MEP COMPONENT ANCHORAGE NOTE
    ALL MECHANICAL, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED PER THE DETAILS ON THE
    DSA-APPROVED CONSTRUCTION DOCUMENTS. THE FOLLOWING COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE
    FORCE AND DISPLACEMENT REQUIREMENTS PRESCRIBED IN THE 2022 CBC SECTIONS 1617A.1.18 THROUGH 1617A.1.26 AND
    ASCE 7-16 CHAPTERS 13, 26, AND 30:
    1. ALL PERMANENT EQUIPMENT AND COMPONENTS.
    2. TEMPORARY, MOVABLE OR MOBILE EQUIPMENT THAT IS PERMANENTLY ATTACHED (E.G., HARD WIRED) TO THE BUILDING
    UTILITY SERVICES SUCH AS ELECTRICITY, GAS OR WATER. “PERMANENTLY ATTACHED” SHALL INCLUDE ALL ELECTRICAL
    CONNECTIONS EXCEPT PLUGS FOR 110/220 VOLT RECEPTACLES HAVING A FLEXIBLE CABLE.
    3. TEMPORARY, MOVABLE OR MOBILE EQUIPMENT WHICH IS HEAVIER THAN 400 POUNDS OR HAS A CENTER OF MASS LOCATED
    4 FEET OR MORE ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT IS REQUIRED TO
    BE RESTRAINED IN A MANNER APPROVED BY DSA.
    THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENTS SHALL BE POSITIVELY ATTACHED TO THE STRUCTURE BUT NEED
    NOT DEMONSTRATE DESIGN COMPLIANCE WITH THE REFERENCES NOTED ABOVE. THESE COMPONENTS SHALL HAVE FLEXIBLE
    CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT. FLEXIBLE
    CONNECTIONS MUST ALLOW MOVEMENT IN BOTH TRANSVERSE AND LONGITUDINAL DIRECTIONS:
    A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVING A CENTER OF MASS LOCATED 4 FEET OR LESS ABOVE THE
    ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT.
    B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTED SYSTEMS, LESS THAN 5 POUNDS PER
    FOOT, WHICH ARE SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL.
    THE ANCHORAGE OF ALL MECHANICAL, ELECTRICAL AND PLUMBING COMPONENTS SHALL BE SUBJECT TO THE APPROVAL OF
    THE DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE OR STRUCTURE ENGINEER DELEGATED RESPONSIBILITY AND
    ACCEPTANCE BY DSA. THE PROJECT INSPECTOR WILL VERIFY THAT ALL COMPONENTS AND EQUIPMENT HAVE BEEN ANCHORED
    IN ACCORDANCE WITH THE ABOVE REQUIREMENTS.
    MEP DISTRIBUTION SYSTEM BRACING NOTE FOR PIPING, DUCTWORK AND ELECTRICAL CONDUIT:
    PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE FORCES AND DISPLACEMENTS
    PRESCRIBED IN ASCE 7 SECTION 13.3 AS DEFINED IN ASCE 7 SECTIONS 13.6.5, 13.6.6, 13.6.7 AND 13.6.8 AND 2022 CBC, SECTIONS 1617A.1.24,
    1617A.1.25 AND 1617A1.26.
    THE METHOD OF SHOWING BRACING AND ATTACHMENTS TO THE STRUCTURE FOR THE IDENTIFIED DISTRIBUTION SYSTEMS ARE AS NOTED
    BELOW. THE MEP DESIGN PROFESSIONAL ENGINEER RESPONSIBLE FOR CONTENT ON THESE SHEETS HAS VERIFIED THAT THE DESIGN
    METHODS IDENTIFIED BELOW ARE IN ACCORDANCE WITH DSA IR 16-13.
    MECHANICAL PIPING (MP), MECHANICAL DUCTS (MD), PLUMBING PIPING (PP), ELECTRICAL DISTRIBUTION SYSTEMS (E):
    MP
    MD
    PP
    E X OPTION 1: PROJECT-SPECIFIC DESIGN.
    GENERAL NOTES
    1. VISIT JOB SITE AND VERIFY EXISTING CONDITIONS PRIOR TO BID.
    2. THE ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
    2022 CALIFORNIA ELECTRICAL CODE AND ALL APPLICABLE LOCAL
    ORDINANCES. WHERE PLANS CALL FOR A HIGHER STANDARD THAN
    APPLICABLE CODES, THE PLANS SHALL GOVERN.
    3. CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATIONS
    SHALL BE DETERMINED IN THE FIELD TO SUIT FIELD CONDITIONS.
    4. ALL ELECTRICAL EQUIPMENT, APPLIANCES AND LIGHTING FIXTURES SHALL BE
    LISTED BY A RECOGNIZED TEST LAB AND BEAR THAT LABEL OF APPROVAL.
    5. CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT ALL MATERIAL AND
    EQUIPMENT FOR THIS WORK UNLESS OTHERWISE NOTED.
    6. FURNISH DISCONNECT SWITCHES AT REMOTE MOTORS.
    7. ALL SPACES AS INDICATED ON PANELS OR SWITCHBOARDS SHALL BE
    COMPLETE WITH HARDWARE AND BUSSING FOR FUTURE BREAKER OR
    SWITCH.
    8. CHECK ARCHITECTURAL PLANS FOR DOOR SWINGS BEFORE INSTALLING
    SWITCH OUTLETS.
    9. GROUNDING AND BONDING SHALL BE PER CODE PLUS ANY ADDITIONAL
    PROVISIONS SPECIFIED OR SHOWN ON DRAWINGS.
    10. ALL CONDUIT RUNS SHALL CONTAIN A CODE SIZED GREEN GROUND WIRE.
    11. THESE PLANS ARE NOT COMPLETE UNTIL APPROVED BY THE AUTHORITY
    HAVING JURISDICTION.
    12. ALL CONDUCTORS SHALL BE IN CONDUIT.
    13. ALL CONDUCTORS SHALL BE COPPER WITH TYPE THHN/THWN INSULATION.
    14. COORDINATE WITH SERVING ELECTRICAL UTILITY COMPANY AND MAKE
    PROVISIONS FOR ELECTRICAL SERVICE ACCORDINGLY. INCLUDE ALL
    SERVICE COSTS AND UTILITY COMPANY CHARGES IN BID.
    15. COORDINATE WITH SERVING TELEPHONE UTILITY COMPANY AND MAKE
    PROVISIONS FOR TELEPHONE SERVICE ACCORDINGLY. INCLUDE ALL
    SERVICE COSTS AND ANY UTILITY COMPANY CHARGES IN BID.
    16. COORDINATE WITH SERVING CABLE TELEVISION COMPANY AND MAKE
    PROVISIONS FOR CABLE TELEVISION ACCORDINGLY. INCLUDE ALL
    SERVICE COSTS AND ANY UTILITY COMPANY CHARGES IN BID.
    17. ALL PERMITS SHALL BE OBTAINED AND PAID FOR BY CONTRACTOR.
    SYMBOLS
    CONDUIT EXISTING
    CONDUIT CONCEALED IN WALL OR CEILING
    CONDUIT CONCEALED UNDER FLOOR OR BELOW GRADE
    CONDUIT STUBBED OUT AND CAPPED
    CONDUIT TURNED UP
    CONDUIT TURNED DOWN
    HATCH MARKS INDICATE NO. OF #12 WIRES IN CODE SIZED
    CONDUIT (3) MAX. IN 1/2" C., (5) MAX. IN 3/4" C.,
    A-3
    (8) MAX. IN 1"C., NO MARKS = 2#12
    HOME RUN: LETTER INDICATES PANEL, NUMBER(S) INDICATES
    CIRCUIT(S).
    SAWCUT
    GROUND CONNECTION
    DISTRIBUTION SWITCHBOARD OR PANEL
    PANEL, BRANCH CIRCUIT TYPE, SURFACE AND FLUSH
    SIGNAL TERMINAL CABINET, SURFACE & FLUSH
    LINEAR SURFACE FIXTURE
    2
    OUTLET DATA: BAR INDICATES WALL MOUNT, LETTER INDICATES
    a
    SWITCH CONTROL, NO. INDICATES CIRCUIT.
    SURFACE FIXTURE ON FLUSH OUTLET.
    RECESSED FIXTURE WITH JUNCTION BOX FOR THRU WIRING
    EXIT LIGHT WITH ARROWS AS SHOWN ON PLANS, WALL AND
    CEILING MOUNT.
    LOW LEVEL EXIT SIGN, +6" AFF, +4" FROM DOOR JAMB
    A
    LIGHT FIXTURE DESIGNATION, LETTER INDICATES TYPE,
    100
    NO. INDICATES WATTAGE. SEE FIXTURE SCHEDULE.
    FC
    1
    M
    GFI
    MECHANICAL EQUIPMENT DESIGNATION.
    SEE MECHANICAL DRAWINGS.
    SPECIAL RECEPTACLE - SEE PLAN
    METER
    FLUSH FLOOR RECEPTACLE
    RECEPTACLE, DUPLEX, 15A, 125V, NEMA 5-15R +18" U.N.O.
    DUPLEX RECEPTACLE MTD. ABOVE BACKSPLASH
    DUPLEX RECEPTACLE W/LOWER HALF SWITCHED
    GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE
    DOUBLE DUPLEX RECEPTACLE
    CEILING RECEPTACLE
    RECEPTACLE, DUPLEX, 20A, 125V, NEMA 5-20R +18" U.N.O.
    J
    JUNCTION BOX 4" SQUARE, 1-1/2" DEEP U.N.O.
    T
    THERMOSTAT F.B.O. +48"
    2
    MOTOR, NO. INDICATES HORSEPOWER
    CLOCK OUTLET +7'-6" U.N.O.
    DISCONNECT SWITCH, NON-FUSED
    F
    DISCONNECT SWITCH FUSED HORSEPOWER RATED OR SIZED AS
    NOTED
    COMBINATION MAGNETIC STARTER WITH DISCONNECT SWITCH AND
    FUSES
    MAGNETIC MOTOR STARTER W/OVERLOADS IN EACH PHASE
    D
    DIMMER W/INTEGRAL "ON-OFF" SW.
    PUSHBUTTON
    PC
    PHOTOCELL
    SD
    SMOKE DETECTOR, INTERCONNECTED W/ BATTERY BACK-UP
    SC
    COMBINATION SMOKE AND CO DETECTOR, INTERCONNECTED
    W/ BATTERY BACK-UP
    TELEPHONE/COMPUTER/DATA OUTLET, TWO GANG BOX W/1 GANG
    COVERPLATE & GROMMETED OPENING +18" U.N.O.
    TV
    CABLE TV OUTLET +18" U.N.O.
    M
    MOTION SENSOR
    S
    EXISTING SWITCH
    S
    SINGLE POLE SWITCH
    S2
    DOUBLE POLE SWITCH QUIET TOGGLE TYPE RATED AT
    S3
    THREE WAY SWITCH
    20A, 120/277V A.C. +42" U.N.O.
    SP
    SWITCH W/PILOT LT.
    SM
    MANUAL MOTOR STARTER
    FACP
    GFI
    LST
    MLO
    w/
    C.O.
    W.P.
    F.B.O.
    U.N.O.
    N.E.C.
    N.I.C.
    (E)
    (N)
    (R)
    (RL)
    S/M
    U/G
    CWP
    AFF
    HACR
    N.L.
    FIRE ALARM CONTROL PANEL
    GROUND FAULT CIRCUIT INTERRUPTING
    LABOR SAVING TANDEM
    MAIN LUGS ONLY
    WITH
    CONDUIT ONLY
    WEATHERPROOF
    FURNISHED BY OTHERS, INSTALL & CONNECT
    UNLESS NOTED OTHERWISE
    NATIONAL ELECTRICAL CODE
    NOT IN CONTRACT
    EXISTING
    NEW
    REMOVE
    RELOCATE
    SURFACE MOUNT
    UNDERGROUND
    COLD WATER PIPE
    ABOVE FINISHED FLOOR
    HEATING AND AIR CONDITIONING RATED
    NIGHT LIGHT
    CIRCUIT BREAKER
    NOTE: NOT ALL SYMBOLS SHOWN ARE USED ON THIS PROJECT.
    HEADQUARTERS OFFICE:
    99 S. Lake Avenue, Suite 300
    Pasadena, CA 91101
    P 323.543.8300
    E-Mail: fm-pasadena@flewelling-moody.com
    ANTELOPE VALLEY OFFICE:
    1035 West Lancaster Boulevard
    Lancaster, California 93534
    P 661.949.0771
    E-Mail: fm-lancaster@flewelling-moody.com
    PE
    ELECTRICAL ENGINEERING
    LIGHTING DESIGN
    CA REGISTRATION NO E13083
    EXTERIOR FINISHES
    AND NEW FENCING AT
    THE EDUCATION SERVICE CENTER
    1051 SOUTH "A" STREET
    OXNARD, CA 93030
    OXNARD SCHOOL DISTRICT
    SYMBOLS, NOTES
    & SCHEDULES
    3210
    10 - 28 - 2025
    BC-
    E-1
    BID CLARIFICATION DRAWING 12/1/2025
    (E) F.H.
    AC
    AC
    (E) MILL BUILDING
    AC
    AC
    CONNECT KEYPAD & INDUCTION
    LOOP BACK TO GATE OPERATOR
    SEE
    A
    E2
    MOTORIZED GATE
    CONNECT GATE
    OPERATOR
    (N)1-1/4"C.W/
    DATA CABLING
    (E) HVAC
    ENCLOSURE
    (N)A-22, 3/4"C.W/
    2#10,1#10GND.
    (E) F.H.
    AC
    (E)DATA ROOM
    (E)PANEL "A"
    (E) EDUCATIONAL SERVICE CENTER
    (E) STORAGE
    BUILDING
    AC
    AC
    (E) F.H.
    AC
    (E) F.H.
    ELECTRICAL SITE PLAN
    SCALE: 1"=30'-0"
    ALLEY
    AC
    GATE OPERATOR
    3/4"C. POWER
    1-1/4"C. DATA
    (NOT IN SCOPE)
    (NOT IN SCOPE)
    (NOT IN SCOPE)
    (NOT IN SCOPE)
    (E) BUILDING
    (NOT IN SCOPE)
    (E)IDF
    (E) BUILDING
    (NOT IN SCOPE)
    (E) BUILDING
    (NOT IN SCOPE)
    (E) BUILDING
    (NOT IN SCOPE)
    (N) 1-1/4"C. W/ DATA CABLING
    KEY PAD
    3/4"C. W/ LOW VOLTAGE CABLE
    3/4"C. W/
    LOW VOLTAGE
    CABLE
    INDUCTION
    LOOP
    ENLARGED PLAN
    A
    SCALE : NONE
    E-2
    FLUSH PULLBOX, UNO
    FINISHED GRADE
    3"
    1/2" GALVINIZED STEEL
    CHECKER PLATE
    H/20 LOADING CENTER
    3"
    COVERING BOTTOM
    3"
    SIZE PER PLAN
    3"
    METAL LATHE
    OPEN BOTTOM
    12"
    GRAVEL
    FLUSH PULLBOX DETAIL
    B
    SCALE : NONE
    E-2
    HEADQUARTERS OFFICE:
    99 S. Lake Avenue, Suite 300
    Pasadena, CA 91101
    P 323.543.8300
    E-Mail: fm-pasadena@flewelling-moody.com
    ANTELOPE VALLEY OFFICE:
    1035 West Lancaster Boulevard
    Lancaster, California 93534
    P 661.949.0771
    E-Mail: fm-lancaster@flewelling-moody.com
    PE
    ELECTRICAL ENGINEERING
    LIGHTING DESIGN
    CA REGISTRATION NO E13083
    (E) BUILDING
    (NOT IN SCOPE)
    CONNECT GATE
    OPERATOR
    B
    11 x 17. SEE
    E2
    (E) HAND BALL
    WALL
    (NOT IN SCOPE)
    (E) BUILDING
    (NOT IN SCOPE)
    (E)LOAD
    CENTER "X"
    CONNECT KEYPAD & INDUCTION
    LOOP BACK TO GATE OPERATOR
    S. "A" S T
    (N)MOTORIZED GATE
    A
    SEE
    E2
    (N)X-12, 3/4"C.W/
    2#10,1#10GND.
    EXTERIOR FINISHES
    AND NEW FENCING AT
    THE EDUCATION SERVICE CENTER
    1051 SOUTH "A" STREET
    OXNARD, CA 93030
    OXNARD SCHOOL DISTRICT
    ELECTRICAL
    SITE PLAN
    North
    3210
    BC-
    E-2
    10 - 28 - 2025
    BID CLARIFICATION DRAWING 12/1/2025
    LIMITED LEAD BASED PAINT SURVEY
    DATE:
    November 6, 2025
    ATTENTION:
    Oxnard School District
    SUBJECT PROPERTY:
    1051 South A Street
    Oxnard, California 93030
    INTRODUCTION:
    On November 4, 2025, Insight Environmental, Inc. performed a Limited Lead-Based Paint
    Survey at the subject property. The purpose of this survey was to determine the presence or
    absence of lead-based paint in the proposed work areas of the property prior to the disturbance
    of building materials. This Survey was limited to the accessible building materials within the
    work areas identified by the client. This survey was conducted by Casey Bressler (CSST #22-
    7273 & CDPH Sampling Technician LRC-00010923) under the supervision of Robert
    Augspurger (CAC #19-6515 & CDPH Inspector/Assessor #LRC-0009459).
    LEAD GUIDELINES:
    The Department of Housing and Urban Development (HUD) Guidelines and the EPAs
    Renovation, Repair, and Paint Rule consider lead levels of 0.5 percent lead by weight (5000
    parts per million (ppm) or mg/kg) or greater; alternatively, an action level of 1 milligram per
    square centimeter or greater, as lead-based paint which may be a potential hazard. In Los
    Angeles County, an action level of 0.7 milligrams per square centimeter has been
    established. In 1978, the Consumer Product Safety Commission (CPSC) banned lead-
    containing paint containing greater than 0.06% (600 ppm) lead in residential paint.
    Cal-OSHA Certified Asbestos Consultant / DHS Lead Certified Inspector Assessor
    Certified Residential Indoor Environmentalist / Radon Measurement Technician / NIOSH 582 Microscopist
    This page summarizes the opportunity, including an overview and a preview of the attached documents.
    * Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

    Sign-up for a Free Trial, Government Bid Alerts

    With Free Trial, you can:

    You will have a full access to bids, website, and receive daily bid report via email and web.

    Try One Week FREE Now

    See Also

    Project ID: Title: HCTP Cleanout and Clarifier Beach Repairs Project (MI 2646) Addenda:

    City of Thousand Oaks

    Bid Due: 6/24/2026

    S33WLCBG - La Cienega Boulevard Green Street Project Status Stage Open Posted 5/27/2026

    City of Los Angeles

    Bid Due: 7/01/2026

    Follow Sources Sought - Paintings & Coatings IDIQ - Edwards AFB Active Contract

    DEPT OF DEFENSE

    Bid Due: 6/26/2026

    Follow Z1DA--Correct Martinez and Mare Island Generator Fuel Lines Active Contract Opportunity Notice

    Federal Agency

    Bid Due: 6/24/2026