6685--Bath VAMC-Temperature/Humidity Monitoring equipment (VA-26-00026567)
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Dec 11, 2025 |
| Due Date: | Dec 18, 2025 |
| Solicitation No: | 36C24226Q0201 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Presolicitation (Original)
- Original Published Date: Dec 11, 2025 10:50 am EST
- Original Response Date: Dec 18, 2025 10:00 am EST
- Inactive Policy: Manual
- Original Inactive Date: Feb 16, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6685 - PRESSURE, TEMPERATURE, AND HUMIDITY MEASURING AND CONTROLLING INSTRUMENTS
-
NAICS Code:
- 334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
-
Place of Performance:
Bath VAMC 76 Veterans Avenue Bath , 14805
Statement of Work
Temperature and Humidity Monitoring
PROJECT NO. 528A6-24-602
Background:
The VA Finger Lakes Health Care System has established a requirement to use the Rotronic Temperature and Humidity monitoring system; as the system of record for the Bath VA Medical Center, located at, 76 Veterans Ave, Bath, NY 14810.
This will ensure that Bath, Canandaigua and Rochester locations will all operate on the same system of record.
Scope:
Vendor shall provide all the required new humidity and temperature monitoring devices for purchase.
Service Requirements:
Vender shall provide new devices, quantities listed below, for the Bath VAMC.
Vendor shall provide devices as indicated in devices purchase base year
Device Purchase - Base year:
Provide the devices models and required shown below to be used for Bath VA Medical center.
Brand
Quantity
Model
Rotronic
66
RMS-MLOG-T10-915 w/ probe
Rotronic
112
RMS-MLOG-B-915
Rotronic
125
915 GATEWAY
Hours:
Work shall be performed Monday Friday between 8:00 am - 4:00 pm, EST or at a time
predetermined with the Contracting Officer Representative (COR) and Vendor.
- 113 HOLLAND AVE
- ALBANY , NY 12208
- USA
- Lorraine A Hussain
- Lorraine.Hussain@va.gov
- Dec 11, 2025 10:50 am ESTPresolicitation (Original)
See Also
Follow 66--OHMMETER Active Contract Opportunity Notice ID N0038326QPB26 Related Notice Department/Ind. Agency DEPT
DEPT OF DEFENSE
Due by 10/15/2026
Follow 66--COMPUTER SUBASSEMBL, IN REPAIR/MODIFICATION OF Active Contract Opportunity Notice ID N0038326QBA66 Related
DEPT OF DEFENSE
Due by 10/02/2026
Follow EPA Region 3 Mercury Vapor Analyzer (RA-915M) Spec Active Contract Opportunity Notice
ENVIRONMENTAL PROTECTION AGENCY
Due by 9/15/2026
Follow ELECTRODE,SODIUM Active Contract Opportunity Notice ID N0010426QEF38 Related Notice Department/Ind. Agency DEPT
DEPT OF DEFENSE
Due by 10/02/2026