B533--VANIHCS SPS Water Testing (VA-27-00000760)

Agency: VETERANS AFFAIRS, DEPARTMENT OF
State: Austrailia's Northern territory
Type of Government: Federal
FSC Category:
  • B - Special Studies and Analyses - Not R&D
NAICS Category:
  • 541380 - Testing Laboratories
Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Posted Date: Oct 4, 2026
Due Date: Nov 4, 2026
Solicitation No: 36C25027R0012
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

Follow
B533--VANIHCS SPS Water Testing (VA-27-00000760)
Active
Contract Opportunity
Notice ID
36C25027R0012
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Presolicitation (Original)
  • Original Published Date: Oct 04, 2026 04:19 pm EDT
  • Original Response Date: Nov 04, 2026 03:00 pm EST
  • Inactive Policy: Manual
  • Original Inactive Date: Nov 19, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: B533 - SPECIAL STUDIES/ANALYSIS- WATER QUALITY
  • NAICS Code:
    • 541380 - Testing Laboratories and Services
  • Place of Performance:
    VA Northern Indiana Healthcare System Fort Wayne VAMC, 46805 ,
Description
MODIFICATION STATEMENT OF WORK
Sterile Processing Service ST-108 Testing Requirements Upgrade
The contractor shall provide all the following for testing the water for/within SPS per the ANSI/AAMI ST108:2023 at the Marion, Fort Wayne, and Jackie Walorski VA sites as defined in this Statement of Work (SOW).
WORK TO BE PERFORMED:
Contractor shall provide all labor, materials, equipment, transportation, lodging, and supervision necessary to collect appropriate samples and deliver to a lab meeting the requirements for processing of AAMI ST108.
Contractor shall calibrate the conductivity/resistivity meter monthly during their testing visit and provide a water analysis report.
The contractor will be part of the multidisciplinary team that assists the water working group with resolving out-of-range water testing, in addition to:
Serves as the subject matter expert on water testing per the ST108:2023
Serves as the subject matter expert on corrective actions to mitigate risks for out-of-range water testing parameters.
Completes monthly, quarterly, and yearly testing per ST108:2023 and the VHA water contract/SOW.
Completes performance qualification testing per the ST108:2023 and per the VHA contract/SOW.
The contractor must report any outliers identified during testing within 24 hours of
receiving laboratory results.
Completes follow-up testing as ordered by engineering for out-of-range water parameters per the ST108:2023 and VHA water contract/SOW.
The contractor shall provide VA end users with access to web-based reporting software for ongoing review of water testing data, historical trends, and compliance documentation.
All reports must clearly highlight or delineate outliers and be designed to provide ease of reading, ensuring information is presented in a clear, organized, and actionable format.
Contractor shall provide consultative services as needed, such as resolving abnormal water testing results, water system analysis, and mitigation of test results.

AAMI ST108 UTILITY WATER, CRITICAL WATER, AND STEAM TESTING BY VENDOR:
Fort Wayne Routine (monthly) POU Testing by Vendor
Fort Wayne Routine (monthly) POU Testing by Vendor
Fort Wayne Routine (monthly) POU Testing by Vendor
Fort Wayne Routine (monthly) POU Testing by Vendor
Fort Wayne Routine (monthly) POU Testing by Vendor
Fort Wayne Routine (monthly) POU Testing by Vendor
Fort Wayne Routine (monthly) POU Testing by Vendor
Fort Wayne Routine (monthly) POU Testing by Vendor
Fort Wayne Routine (monthly) POU Testing by Vendor
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Utility
Routine Sample Site
Critical
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Utility
Routine Sample Site
Critical
Utility Water
Utility Water
Critical Water
Critical Water
pH
pH
pH Meter or Colorimetric dipsticks
Medivator Basin x4
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
6.5-9.5
Monthly
5.0-7.5
Monthly
Conductivity
uS/cm
Conductivity Meter
Medivator Basin x4
Decon sinks x3
Washer x1
Ultrasonic x1
Eye UltrasonicX1
Monthly
Monthly
Total Alkalinity
mg CaCO3/L
Colorimetric dipsticks or Alkalinity test kit
Medivator Basin x4
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Monthly
Monthly
Total Hardness
mg CaCO3/L
Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter
Medivator Basin x4
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Monthly
Monthly
Bacteria
CFU/mL
Heterotrophic Plate Count (HPC)
NA
Decon sinks x3
Medivator Basin x4
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Monthly
Monthly
Endotoxin
EU/mL
LAL Test
NA
Decon sinks x3
Medivator Basin x4
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
NA
NA
Monthly

Fort Wayne Point of Generation Routine (monthly) Testing by Vendor
Fort Wayne Point of Generation Routine (monthly) Testing by Vendor
Fort Wayne Point of Generation Routine (monthly) Testing by Vendor
Fort Wayne Point of Generation Routine (monthly) Testing by Vendor
Fort Wayne Point of Generation Routine (monthly) Testing by Vendor
Fort Wayne Point of Generation Routine (monthly) Testing by Vendor
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Critical
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Critical
Critical Water
Critical Water
pH
pH
pH Meter or Colorimetric dipsticks
Loop Supply
Loop Return
5.0-7.5
Monthly
Conductivity
uS/cm
Conductivity Meter (in line or measurement of a collected sample)
Loop Supply
Loop Return
Monthly
Total Alkalinity
mg CaCO3/L
Colorimetric dipsticks or Alkalinity test kit
Loop Supply
Loop Return
Monthly
Total Hardness
mg CaCO3/L
Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter
Loop Supply
Loop Return
Monthly
Bacteria
CFU/mL
Heterotrophic Plate Count (HPC)
Loop Supply
Loop Return
Monthly
Endotoxin
EU/mL
LAL Test
Loop Supply
Loop Return
Monthly

Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor
Water Quality Measurement
Units
Type of Testing
PQ Sample Site
Utility
PQ Sample Site
Critical
PQ Sample Site
Steam
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Water Quality Measurement
Units
Type of Testing
PQ Sample Site
Utility
PQ Sample Site
Critical
PQ Sample Site
Steam
Utility Water
Utility Water
Critical Water
Critical Water
Steam
Steam
pH
pH
pH Meter or Colorimetric dipsticks
Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
6.5-9.5
Quarterly
5.0-7.5
Monthly
5.0-9.2
Quarterly
Conductivity
uS/cm
Conductivity Meter
Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Monthly
Quarterly
Total Alkalinity
mg CaCO3/L
Colorimetric dipsticks or Alkalinity test kit
Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Monthly
Quarterly
Total Hardness
mg CaCO3/L
Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter
Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Monthly
Quarterly
Total Organic Carbon (TOC)
mg/L (ppm)

NA
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
NA
NA
NA
Quarterly
NA
NA
Aluminum
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Chloride
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Copper
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Iron
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Manganese
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Nitrate
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Phosphate
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Silicate
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Sulfate
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Zinc
mg/L

Decon sinks x4
Medivator Basin x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Bacteria
CFU/mL
Heterotrophic Plate Count (HPC)
Decon sinks x4
Washer x2
Ultrasonic x2
Eye Ultrasonic X2
City Water
Water Softener
Utility DI
After Carbon Filter
Medivator 1 Supply Medivator 2 Supply
Decon sinks x3
Medivator basin x4
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
NA
Quarterly
Monthly
NA
NA
Endotoxin
EU/mL
LAL Test
NA
Decon sinks x3
Medivator basin x4
Washer x1
Ultrasonic x1
Eye Ultrasonic X1
Loop Supply
Loop Return
After RO
After DI
NA
NA
NA
Monthly
NA
NA

Marion Routine (monthly) POU Testing by Vendor
Marion Routine (monthly) POU Testing by Vendor
Marion Routine (monthly) POU Testing by Vendor
Marion Routine (monthly) POU Testing by Vendor
Marion Routine (monthly) POU Testing by Vendor
Marion Routine (monthly) POU Testing by Vendor
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Critical
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Critical
Critical Water
Critical Water
pH
pH
pH Meter or Colorimetric dipsticks
Decon sinks x1
Washer x1
5.0-7.5
Monthly
Conductivity
uS/cm
Conductivity Meter
Decon sinks x1
Washer x1
Monthly
Total Alkalinity
mg CaCO3/L
Colorimetric dipsticks or Alkalinity test kit
Decon sinks x1
Washer x1
Monthly
Total Hardness
mg CaCO3/L
Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter
Decon sinks x1
Washer x1
Monthly
Bacteria
CFU/mL
Heterotrophic Plate Count (HPC)
Decon sinks x1
Washer x1
Monthly
Endotoxin
EU/mL
LAL Test
Decon sinks x1
Washer x1
Monthly

Marion Point of Generation Routine (monthly) Testing by Vendor
Marion Point of Generation Routine (monthly) Testing by Vendor
Marion Point of Generation Routine (monthly) Testing by Vendor
Marion Point of Generation Routine (monthly) Testing by Vendor
Marion Point of Generation Routine (monthly) Testing by Vendor
Marion Point of Generation Routine (monthly) Testing by Vendor
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Critical
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Critical
Critical Water
Critical Water
pH
pH
pH Meter or Colorimetric dipsticks
Supply
5.0-7.5
Monthly
Conductivity
uS/cm
Conductivity Meter (in line or measurement of a collected sample)
Supply
Monthly
Total Alkalinity
mg CaCO3/L
Colorimetric dipsticks or Alkalinity test kit
Supply
Monthly
Total Hardness
mg CaCO3/L
Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter
Supply
Monthly
Bacteria
CFU/mL
Heterotrophic Plate Count (HPC)
Supply
Monthly
Endotoxin
EU/mL
LAL Test
Supply
Monthly

Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Marion Performance Qualification Testing (quarterly) Testing by Vendor
Water Quality Measurement
Units
Type of Testing
PQ Sample Site
Utility
PQ Sample Site
Critical
PQ Sample Site
Steam
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Water Quality Measurement
Units
Type of Testing
PQ Sample Site
Utility
PQ Sample Site
Critical
PQ Sample Site
Steam
Utility Water
Utility Water
Critical Water
Critical Water
Steam
Steam
pH
pH
pH Meter or Colorimetric dipsticks
Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
6.5-9.5
Quarterly
5.0-7.5
Monthly
5.0-9.2
Quarterly
Conductivity
uS/cm
Conductivity Meter
Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Monthly
Quarterly
Total Alkalinity
mg CaCO3/L
Colorimetric dipsticks or Alkalinity test kit
Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Monthly
Quarterly
Total Hardness
mg CaCO3/L
Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter
Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Monthly
Quarterly
Total Organic Carbon (TOC)
mg/L (ppm)

NA
Decon sinks x1
Washer x1
Supply
After RO
After DI
NA
NA
NA
Quarterly
NA
NA
Aluminum
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Chloride
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Copper
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Iron
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Manganese
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Nitrate
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Phosphate
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Silicate
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Sulfate
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Zinc
mg/L

Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
Sterilizer x2
Quarterly
Quarterly
Quarterly
Bacteria
CFU/mL
Heterotrophic Plate Count (HPC)
Decon sinks x2
Washer x2
Ultrasonic x2
City Water
Water Softener
Utility DI
After Carbon Filter
Decon sinks x1
Washer x1
Supply
After RO
After DI
NA
Quarterly
Monthly
NA
NA
Endotoxin
EU/mL
LAL Test
NA
Decon sinks x1
Washer x1
Supply
After RO
After DI
NA
NA
NA
Monthly
NA
NA

JWC Performance Qualification Testing (quarterly) Testing by Vendor
JWC Performance Qualification Testing (quarterly) Testing by Vendor
JWC Performance Qualification Testing (quarterly) Testing by Vendor
JWC Performance Qualification Testing (quarterly) Testing by Vendor
JWC Performance Qualification Testing (quarterly) Testing by Vendor
JWC Performance Qualification Testing (quarterly) Testing by Vendor
JWC Performance Qualification Testing (quarterly) Testing by Vendor
JWC Performance Qualification Testing (quarterly) Testing by Vendor
JWC Performance Qualification Testing (quarterly) Testing by Vendor
Water Quality Measurement
Units
Type of Testing
PQ Sample Site
Utility
PQ Sample Site
Critical
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Water Quality Measurement
Units
Type of Testing
PQ Sample Site
Utility
PQ Sample Site
Critical
Utility Water
Utility Water
Critical Water
Critical Water
pH
pH
pH Meter or Colorimetric dipsticks
Decon sink x2
Medivator Basin x4
Water Softener
City Water Medivator 30 Supply Medivator 31 Supply
NA
6.5-9.5
Quarterly
5.0-7.5
Monthly
Conductivity
uS/cm
Conductivity Meter
Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Monthly
Total Alkalinity
mg CaCO3/L
Colorimetric dipsticks or Alkalinity test kit
Decon sink x2
Medivator Basin x4
Water Softener
City Water
NA
Quarterly
Monthly
Total Hardness
mg CaCO3/L
Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter
Decon sink x2
Medivator Basin x4
Water Softener
City Water
NA
Quarterly
Monthly
Total Organic Carbon (TOC)
mg/L (ppm)

NA
NA
NA
NA
Quarterly
Aluminum
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Chloride
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Copper
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Iron
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Manganese
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Nitrate
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Phosphate
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Silicate
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Sulfate
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Zinc
mg/L

Decon sink x2
Medivator Basin x4
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
NA
Quarterly
Quarterly
Bacteria
CFU/mL
Heterotrophic Plate Count (HPC)
Decon sink x2
Water Softener
City Water
Medivator 30 Supply Medivator 31 Supply
Medivator Basin x4
Quarterly
Monthly
Endotoxin
EU/mL
LAL Test
NA
Medivator Basin x4
NA
NA
Monthly

JWC Routine (monthly) POU Testing by Vendor
JWC Routine (monthly) POU Testing by Vendor
JWC Routine (monthly) POU Testing by Vendor
JWC Routine (monthly) POU Testing by Vendor
JWC Routine (monthly) POU Testing by Vendor
JWC Routine (monthly) POU Testing by Vendor
JWC Routine (monthly) POU Testing by Vendor
JWC Routine (monthly) POU Testing by Vendor
JWC Routine (monthly) POU Testing by Vendor
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Utility
Routine Sample Site
Critical
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Minimum Frequency of Testing and Testing Range
Water Quality Measurement
Units
Type of Testing
Routine Sample Site
Utility
Routine Sample Site
Critical
Utility Water
Utility Water
Critical Water
Critical Water
pH
pH
pH Meter or Colorimetric dipsticks
Medivator Basin x4
NA
6.5-9.5
Monthly
5.0-7.5
Monthly
Conductivity
uS/cm
Conductivity Meter
Medivator Basin x4
NA
Monthly
Monthly
Total Alkalinity
mg CaCO3/L
Colorimetric dipsticks or Alkalinity test kit
Medivator Basin x4
NA
Monthly
Monthly
Total Hardness
mg CaCO3/L
Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter
Medivator Basin x4
NA
Monthly
Monthly
Bacteria
CFU/mL
Heterotrophic Plate Count (HPC)
NA
Medivator Basin x4
Monthly
Monthly
Endotoxin
EU/mL
LAL Test
NA
Medivator Basin x4
NA
NA
Monthly
SPECIAL WORK REQUIREMENTS:
Hours of Operation: Onsite testing is to be conducted on the first Federal working day of the month. Â Onsite services shall be performed during normal business hours of 8:00 AM to 4:00 PM, Monday Friday, excluding Federal holidays. Â Observed holidays are: New Year s Day, Martin Luther King Jr. Day, Presidents Day, Memorial Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, Christmas Day, and any other day specifically declared a holiday by the President of the United States.
Attachments/Links
Contact Information
Contracting Office Address
  • VISN 10 CONSOLIDATED CONTRACTING 4100 WEST 3RD STREET
  • DAYTON , OH 45428
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Oct 04, 2026 04:19 pm EDTPresolicitation (Original)

Related Document

Oct 20, 2026[Combined Synopsis/Solicitation (Original)] B533--VANIHCS SPS Water Testing (VA-27-00000760)
Oct 21, 2026[Presolicitation (Updated)] B533--VANIHCS SPS Water Testing (VA-27-00000760)
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.