B369 Boiler
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | Nebraska |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Apr 30, 2026 |
| Due Date: | May 11, 2026 |
| Solicitation No: | B369_Boiler |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Updated)
- Updated Published Date: Apr 30, 2026 02:12 pm CDT
- Original Published Date: Apr 30, 2026 01:52 pm CDT
- Updated Response Date: May 11, 2026 11:00 am CDT
- Original Response Date: May 11, 2026 11:00 am CDT
- Inactive Policy: 15 days after response date
- Updated Inactive Date: May 26, 2026
- Original Inactive Date: May 26, 2026
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 4410 - INDUSTRIAL BOILERS
-
NAICS Code:
- 332410 - Power Boiler and Heat Exchanger Manufacturing
-
Place of Performance:
Offutt AFB , NE 68113USA
The scope of work is to provide a new NTI model LX-600 boiler; 600,000 BTU input, with ASME SS heat exchanger, floor-mount, factory-provided ASME relief valve, at least 4 to 1 turn down, 95% combustion efficiency, 4” exhaust vent and 4” fresh air intake, with outdoor sensor, CSD-1 controls, integrated electronic controller with touch screen access, and factory-installed condensate trap and included condensate drain kit.
The hydronic gas boiler must be at least 600 MBH capacity, with at least 4:1 turndown on natural gas, and dimensions no larger than 24"wide x 47.5"deep(long) x 55" high, with water (2") and gas (1") connections along the left-hand length side and air inlet/exhaust (4") connections along the top or left-hand length side.
The Contractor shall provide at least a 1-year comprehensive warranty on all new materials.
- ADMIN ONLY NO REQTN CP 402 232 6459 106 PEACEKEEPER DR BLDG 3 STE 2N3
- OFFUTT AFB , NE 68113
- USA
- TSgt Jennifer Prestridge
- jennifer.prestridge.1@us.af.mil
- Phone Number 4022946393
- Casey Hupton
- casey.hupton.1@us.af.mil
- Phone Number 4022321475
- Apr 30, 2026 02:12 pm CDTSources Sought (Updated)
- Apr 30, 2026 01:52 pm CDT Sources Sought (Original)
See Also
WEC 1 Aux Boiler Tube Replacement HU 2026-80 Open: 2026-09-08 Status: Active Department:
City of Hastings