Available for Licensing: Machine Learning-Enhanced Spectroscopy Technology for High-Resolution Radiation Detection Using Low-Cost Detectors

Agency:
State: Idaho
Type of Government: Federal
FSC Category:
  • 66 - Instruments and Laboratory Equipment
NAICS Category:
  • 334516 - Analytical Laboratory Instrument Manufacturing
Posted Date: Jun 17, 2026
Due Date: Aug 1, 2026
Solicitation No: BA-1346
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Follow
Available for Licensing: Machine Learning-Enhanced Spectroscopy Technology for High-Resolution Radiation Detection Using Low-Cost Detectors
Active
Contract Opportunity
Notice ID
BA-1346
Related Notice
Department/Ind. Agency
ENERGY, DEPARTMENT OF
Sub-tier
ENERGY, DEPARTMENT OF
Office
BATTELLE ENERGY ALLIANCE–DOE CNTR
General Information View Changes
  • Contract Opportunity Type: Special Notice (Updated)
  • Updated Published Date: Jun 17, 2026 12:11 pm MDT
  • Original Published Date: Oct 30, 2025 11:32 am MDT
  • Updated Response Date: Aug 01, 2026 12:00 am MDT
  • Original Response Date: Dec 01, 2025 12:00 am MST
  • Inactive Policy: 15 days after response date
  • Updated Inactive Date: Aug 16, 2026
  • Original Inactive Date: Dec 16, 2025
  • Initiative:
Classification
  • Original Set Aside:
  • Product Service Code: 6635 - PHYSICAL PROPERTIES TESTING AND INSPECTION
  • NAICS Code:
    • 334516 - Analytical Laboratory Instrument Manufacturing
  • Place of Performance:
    Idaho Falls , ID 83401
    USA
Description

Machine Learning-Enhanced Spectroscopy Technology for High-Resolution Radiation Detection Using Low-Cost Detectors



Transforms low-energy resolution gamma- and x-ray detector data into high-resolution spectra—reducing cost, size, and cooling requirements without sacrificing performance.



Technology Summary



This INL technology enables high-energy-resolution radiation spectroscopy using low-cost, room-temperature detectors such as sodium iodide (NaI) scintillators. Traditionally, researchers and engineers rely on high-purity germanium (HPGe) detectors, lanthanum bromide (LaBr3) or similar for applications requiring fine energy discrimination; however, these systems are expensive, fragile, or require cryogenic cooling.



The presented approach applies a compact convolutional neural network (CNN) architecture to reconstruct high-energy-resolution spectra from low-resolution measurements. Using four convolution-max pooling layer pairs (128–16 filters) followed by dense layers, the model captures spectral features typically only visible with HPGe detectors. The network contains roughly 1.6 million parameters (6.2 MB total), enabling fast, portable deployment in embedded or field devices.



The technology offers a new analytical pathway for radiation spectroscopy—maintaining data fidelity while reducing total system cost, weight, and operational complexity.



Problem Addressed





  • High cost and complexity of high-energy-resolution detectors: HPGe systems provide excellent energy resolution (~0.2%) but are 10×–100× more expensive than scintillation-based systems.







  • Limited operational flexibility: HPGe detectors require cryogenic cooling and are unsuitable for mobile or high-radiation environments.







  • Low detection efficiency and count-rate performance: HPGe detectors have lower detection efficiency per detector volume and cannot handle high count rates without peak deformation or detector dead time, leading to data degradation.







  • Restricted deployment scenarios: Field, space-based, and confined monitoring applications require detectors that are robust, efficient, and thermally independent.





Solution





  • Data-driven energy resolution enhancement: Employs a convolutional neural network to reconstruct high-resolution spectra from low-resolution detector inputs.







  • Compact, deployable model: 1.6M-parameter neural network (6.2 MB) allows rapid inference on low-power devices.







  • Detector-agnostic implementation: Can be adapted for gamma, x-ray, neutron, or charged-particle spectroscopy.







  • Scalable to various hardware: Applicable to NaI, CsI, or plastic scintillators, enabling energy peak discrimination comparable to HPGe without cryogenic operation.





Key Advantages





  • Cost Reduction: Enables ≥10× lower system cost and maintenance by replacing HPGe with NaI or other inexpensive detectors.







  • Operational Simplicity: Eliminates need for liquid nitrogen or cryogenic cooling systems.







  • Higher Throughput: Supports higher count rates with minimal peak deformation.







  • Improved Deployability: Suitable for remote, field, and mobile environments where HPGe is impractical.







  • Cross-Technology Applicability: Adaptable for gamma-ray, x-ray, and neutron detection systems.





Market Applications





  • Nuclear materials monitoring and safeguards – real-time isotope discrimination without cryogenic infrastructure.







  • Space-based radiation detection – lightweight, low-power alternative to HPGe for satellite payloads.







  • Industrial quality control and non-destructive testing – improved spectral resolution using existing NaI-based systems.







  • Medical and environmental radiation monitoring – portable spectrometers with enhanced fidelity for imaging and dosimetry.







  • Homeland security and defense – deployable gamma-ray detection for special nuclear material tracking.





This notice is not a solicitation for funding or a commitment by DOE/INL to procure services. Rather, it is intended solely to notify industry of an INL technology available for licensing and commercialization.


Attachments/Links
Contact Information
Contracting Office Address
  • 1955 N Fremont Avenue
  • Idaho Falls , ID 83415
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Oct 6, 2025[Combined Synopsis/Solicitation (Updated)] Energy Resolution Upscaling for Radiation Detectors
Oct 30, 2025[Special Notice (Original)] Available for Licensing: Machine Learning-Enhanced Spectroscopy Technology for High-Resolution Radiation Detection Using Low-Cost Detectors
Mar 4, 2026[Special Notice (Updated)] Available for Licensing: Machine Learning-Enhanced Spectroscopy Technology for High-Resolution Radiation Detection Using Low-Cost Detectors
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Follow 124 ASOS Optics and Mounts Active Contract Opportunity Notice ID W50S7326QA003 Related

DEPT OF DEFENSE

Bid Due: 8/20/2026

Follow 1232SA26Q1193 Combo Synopsis/Solicitation HR Accurate Mass LC-MS Measurement System USDA-ARS-PWA Hagerman ID

AGRICULTURE, DEPARTMENT OF

Bid Due: 8/19/2026

Follow 124 ASOS Optics and Mounts Active Contract Opportunity Notice ID W50S7326QA003 Related

DEPT OF DEFENSE

Bid Due: 8/20/2026

Follow 124 ASOS Optics and Mounts Active Contract Opportunity Notice ID W50S7326QA003 Related

DEPT OF DEFENSE

Bid Due: 8/20/2026