AJJY 25-1074M Repair Saipan Dorm - Andersen AFB, Guam
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | Guam |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Jun 2, 2025 |
| Due Date: | Jun 17, 2025 |
| Solicitation No: | FA524025R0004 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Presolicitation (Original)
- Original Published Date: Jun 02, 2025 01:20 pm JST
- Original Response Date: Jun 17, 2025 01:00 pm JST
- Inactive Policy: 15 days after response date
- Original Inactive Date: Jul 02, 2025
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: Z2FC - REPAIR OR ALTERATION OF TROOP HOUSING FACILITIES
-
NAICS Code:
- 236220 - Commercial and Institutional Building Construction
-
Place of Performance:
Yigo , GU 96929USA
Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Saipan Dorm B250007.
DESCRIPTION OF WORK:
The contractor shall design and fully repair Saipan Dorm B25007 to renovate interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems. B25007 is conditioned by chilled water and a central chiller plant, and both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. B25007 must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets buried with debris, dirt, and grass are to be cleared.
Please see attachment for more details. Thank you!
- (ADMIN ONLY NO REQTN) UNIT 14040
- APO , AP 96543-4040
- USA
- Lt Shelby Benko
- shelby.benko.1@us.af.mil
- Phone Number 671-366-6627
- Mr. Eddie Pelkey
- eddie.pelkey@us.af.mil
- Phone Number 671-366-6576
- Jun 02, 2025 01:20 pm JSTPresolicitation (Original)
Related Document
| Jul 16, 2025 | [Solicitation (Updated)] AJJY 25-1074M Repair Saipan Dorm B25007 |
| Aug 7, 2025 | [Solicitation (Updated)] AJJY 25-1074M Repair Saipan Dorm B25007 |
| Aug 8, 2025 | [Solicitation (Updated)] AJJY 25-1074M Repair Saipan Dorm B25007 |
| Aug 12, 2025 | [Solicitation (Updated)] AJJY 25-1074M Repair Saipan Dorm B25007 |
| Aug 13, 2025 | [Solicitation (Updated)] AJJY 25-1074M Repair Saipan Dorm B25007 |
| Sep 25, 2025 | [Award Notice (Original)] AJJY 25-1074M Repair Saipan Dorm B25007 |
See Also
GSA-054-26 - HVAC CHILLED WATER SYSTEM PUMP, MOTOR, AND VFD REPLACEMENT AND INSTALLATION
Guam General Services Agency (GSA)
Due by 9/17/2026