Y--Install New Floors in the Pharmacy IV Room

Agency: VETERANS AFFAIRS, DEPARTMENT OF
State: New York
Type of Government: Federal
FSC Category:
  • Y - Construction of Structures and Facilities
NAICS Category:
  • 238330 - Flooring Contractors
Posted Date: Dec 11, 2019
Due Date:
Solicitation No: 36C24220R0029
Bid Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Y--Install New Floors in the Pharmacy IV Room
Active
Contract Opportunity
Notice ID
36C24220R0029
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
General Information
  • Contract Opportunity Type: Presolicitation (Original)
  • All Dates/Times are: (UTC-05:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: Dec 10, 2019 02:16 pm EST
  • Original Response Date:
  • Inactive Policy: Manual
  • Original Inactive Date: Jan 09, 2020
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: Y - CONSTRUCT OF STRUCTURES/FACILITIES
  • NAICS Code: 238330 - Flooring Contractors
  • Place of Performance:
    Department of Veterans Affairs;James J Peters VA Medical Center;Pharmacy IV Room 1B;130 West Kingsbridge Rd.;Bronx, NY 10468
    USA
Description
This notice is for Solicitation Number 36C24220R0029 - Install new floors in the Pharmacy IV Room 1B at James J. Peters VA Medical Center, 130 West Kingsbridge Rd. Bronx, New York, 10468. This shall be a Service-Disabled Veteran Owned Small Business Set-Aside (SDVOSB). As a result, all SDVOSB's may submit an offer, which will be considered by the agency. This project is classified under NAICS Code 238330 and has a size standard of $16.5 Million. The cost estimate range for this project is $25,000.00 to $100,000.00. SCOPE OF WORK: Install new floors in the Pharmacy IV Room 1B. This work is to be done using the product described below or an approved equivalent. See PRODUCT DESCRIPTION AND PHYSICAL CHATACTERISTICS below. This is to prepare and coat the floors in the Pharmacy IV Room in 1B of approx. 633 square feet Scope of Work (I.V. Room). The contractor shall remove the existing old floor (sheet viny). There is no asbestos under current floor as it was removed during the last renovation eight (8) years ago. This room is currently empty and does not require removal of any plumbing, partitions, insulations, barriers, etc. Mechanically prepare all accessible areas with the use of a Blastrac machine. This procedure removes: All surface laitance, oil, grease and dirt from the substrate and provides a mechanical profile to enhance bonding. Stonblend GSI - A three-component, troweled, 3/16" mortar consisting of epoxy resin, curing agent. Colored quartz silica aggregate, a two-component, clear UV resistant epoxy grout coat sealer and a two component, Water based, non-reflective aliphatic polyurethane coating. New flooring does not require bracing. New flooring does not require stripping and waxing after installation. Contractor shall be responsible for removing all debris. New flooring requires at least 1-year warranty from acceptance date. PRODUCT DESCRIPTION AND PHYSICAL CHARACTERISTICS Stonblend GSI-G is a nominal 3/16 in./5 mm flooring system that offers a cost-effective alternative to terrazzo and incorporates recycled glass in the surface of the floor. It combines striking, decorative looks, excellent chemical and wear resistance, cleanibility and UV resistance with an easy to maintain surface. All standard colors contain 10% recycled glass chips per unit. PHYSICAL CHARACTERISTICS Compressive Strength . . . . . . . . . . . ................ 6,000 psi (ASTM C579) ........................................ after 7 days Tensile Strength . . . . . . . . . . . . . . . . . . . . . . .... 1,500 psi (ASTM C-307) Flexural Strength . . . . . . . . . . . . . . . . . . . . . . .... 2,200 psi (ASTM C-580) Flexural Modulus of Elasticity. . . . . . . . . . . .... 5.0 x 105psi (ASTM C-580) Hardness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .... 85 to 90 (ASTM D-2240, Shore D) Impact Resistance. . . . . . . . . . . . . . . . . . . . ... >160 in./lbs (ASTM D-2794) Abrasion Resistance . . . . . . ... .0.06 gm max. weight loss (ASTM D-4060, CS-17) Flammability (ASTM E-648, E-662). . . . . . . . . . . . . . . . . . . . ... Class 1 Thermal Coefficient of Linear Expansion . . . . . . . . . . . . . . .... .1.3 x 10-5 in./in.°F (ASTM C-531) VOC Content . . . . . . . . . . . . . ... Stonblend Primer - 75 g/l (ASTM D-2369, Method E) Stonblend GSI-G Base -17 g/l ............................................ Stonblend Grout Coat - 52 g/l ......................................................... Stonkote CE4 - 34 g/l ...................................... Stonseal CF7 - 47 g/l (Method C) Cure Rate . . . . . . . . . . . . . . . . . . . 12 hours for foot traffic (@ 77°F/25°C) 24 hours for normal operations Note: The above physical properties were measured in accordance with the referenced standards. Samples of the actual floor system, including binder and filler, were used as test specimens. All sample preparation and testing is conducted in a laboratory environment, values obtained on field applied materials may vary and certain test methods can only be conducted on lab made test coupons. PROJECT COMPLETION: 28 Calendar Days All other details and information shall be contained in the solicitation which shall be posted on www.fbo.gov. The solicitation will be released on or about 12/20/2019. The response submittal address, date and time will be included in the solicitation. This project requires bonding. All prospective bidders must be currently registered in www.sam.gov and be registered and verified as a SDVOSB in www.vip.vetbiz.gov at the time of offer submission and before award of this procurement. End of Description.
Attachments/Links
Contact Information
Contracting Office Address
  • ALBANY , NY 12208
Primary Point of Contact
Secondary Point of Contact


History
  • Dec 10, 2019 02:16 pm ESTPresolicitation (Original)

Related Document

Jan 17, 2020[Solicitation (Original)] Y--Install New Floors in the Pharmacy IV Room

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Issue Date: 03/10/2020 Contract Number: Q20-6922SR Quarryville Solar PV Project Description: The New

The New York State Contract Reporter

Bid Due: 4/21/2020

Title: BID EXTENSION: HANNAH ST. PUMPING STATION UPGRADE Procurement Section Environmental Protection (DEP)

The City of New York

Bid Due: 4/14/2020

Title: BID EXTENSION: DEMOLITION AND SITE PREPARATION FOR GOWANAS CANAL CSO FACILITY, BROOKLYN,

The City of New York

Bid Due: 4/28/2020

Issue Date: 03/11/2020 Contract Number: PIN 395062 NYS Route 96B (Danby Road) Sidewalk

The New York State Contract Reporter

Bid Due: 4/09/2020