Fire Station No. 4 Repairs

Agency: City of Pleasanton
State: California
Type of Government: State & Local
Posted Date: Jun 29, 2018
Due Date: Aug 2, 2018
Solicitation No: CIP No. 11429
Bid Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Fire Station No. 4 Repairs

Description

**In order to be an eligible bidder, plans, specifications and all bid proposal and contract documents must be purchased from the Engineering Department of the City of Pleasanton** This work will consist of complete removal and replacement of the entire roofing material up to the plywood sheeting and the parapet walls, including the waterproofing and flashing systems, followed by exterior painting of the entire Fire Station No. 4 building. This work is necessary as the roof is showing age and is close to the end of its life cycle; the flashing as-installed on the parapet wall is allowing water intrusion into the building. Work shall also include a single window replacement. The Engineer's cost estimate for the project is $260,00, including a $25,000 allowance.

Project Number: CIP No. 11429
Advertisement Date : June 28, 2018
Bid Date :
Aug 02, 2018 by 2:00pm
Submittal Address :

Mailing: Delivery:

City Clerk's Office City Clerk's Office
City of Pleasanton City of Pleasanton
P.O. Box 520 123 Main Street
Pleasanton, CA 94566 Pleasanton, CA 94566

Online Bid Packet

PLANS
SPECS

Contact:

Adam Nelkie
Senior Civil Engineer
925-931-5675

anelkie@cityofpleasantonca.gov

Online Bid Response : Online Bid Response: Online Bid Response is not available for this City Bid.

Attachment Preview

Abbreviations
&
L
@
CL
oI
#
ACOUS.
A.D.
ADJ.
AGGR.
ALUM.
APPROX.
ARCH.
ASPH.
BD.
BITUM.
BLDG.
BLK.
BLKG.
BM.
BOT.
CAB.
C.B.
CEM.
CER.
C.I.
CJ
CLG.
CLKG.
CLO.
CLR.
COL.
CONC.
CONN.
CONSTR.
CONT.
CORR.
CTSK.
C.T.
DBL.
DET
DIA.
DIM.
DISP.
DN.
DWR.
DS.
D.S.P.
DWG.
E.
EA.
E.J.
ELE.
ELEC.
ELEV.
EMER.
ENCL.
EQ.
EQPT.
EXST.
EXPO.
EXP.
EXT
F.A.
F.D.
FDN
F.E.
F.E.C.
F.H.C.
FIN.
FL
FLASH
FLUOR.
F.O.B.
F.O.C.
F.O.F.
F.O.S.
F.S.
FT
FTG.
FURR.
F.F.E.
GA.
GALV.
G.B.
GLASS
GR
GYP.
H.B.
H.C.
HDWD.
HDW.
H.M.
HORIZ.
HGT.
AND
ANGLE
AT
CENTERLINE
DIAMETER OR ROUND
POUND OR NUMBER
ACOUSTICAL
AREA DRAIN
ADJUSTABLE
AGGREGATE
ALUMINUM
APPROXIMATE
ARCHITECTURAL
ASPHALT
BOARD
BITUMINOUS
BUILDING
BLOCK
BLOCKING
BEAM
BOTTOM
CABINET
CATCH BASIN
CEMENT
CERAMIC
CAST-IRON
CONTROL JOINT
CEILING
CAULKING
CLOSET
CLEAR
COLUMN
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
CORRIDOR
COUNTERSUNK
CERAMIC TILE
DOUBLE
DETAIL
DIAMETER
DIMENSION
DISPENSER
DOWN
DRAWER
DOWNSPOUT
DRY STANDPIPE
DRAWING
EAST
EACH
EXPANSION JOINT
ELEVATION
ELECTRICAL
ELEVATION
EMERGENCY
ENCLOSURE
EQUAL
EQUIPMENT
EXISTING
EXPOSED
EXPANSION
EXTERIOR
FIRE ALARM
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FIRE HOSE CABINET
FINISH
FLOOR
FLASHING
FLUORESCENT
FACE OF BLOCK
FACE OF CONCRETE
FACE OF FINISH
FACE OF STUDS
FULL SIZE
FOOT OR FEET
FOOTING
FURRING
FINISHED FLOOR ELEVATION
GAUGE
GALVANIZED
GRAB BAR
GLASS
GRADE
GYPSUM
HOSE BIB
HOLLOW CORE
HARDWOOD
HARDWARE
HOLLOW METAL
HORIZONTAL
HEIGHT
I.D.
INSUL.
INT.
IRRIG.
JT.
LAM.
LAV.
MAX.
M.C.
MECH.
MET.
MFR.
MIN.
MISC
M.O.
MTD.
NO.
N.I.C.
N.T.S.
O.A.
O.C.
O.D.
OPNG.
OPP.
PC.
PL.
P.LAM.
PLAS.
PLYWD
PR.
PT.
P.T.DISP.
RECP.
RAD.
R.D.
REF.
REFR.
REINF.
REQ.
RM.
R.O.
RS.
RWD.
R.W.L.
SO.
S.C.
S.C.DISP.
SCHD.
S.DISP.
SECT.
SH.
SHR.
SIM
SPEC.
SQ.
ST.STL.
STA.
STD.
STL.
STOR.
STRUC.
SUSP.
SYM.
S.M.
T.C.
TEL.
TER.
TG
T&G
THK.
T.P.
T.P.DISP.
T.V.
T.W.
TYP.
T.O.
T.O.P.
U.O.N.
UR
VERT.
VEST.
V.I.F.
V.T.R.
W
W/
W.C.
WD.
W/O
WP.
WPJ
WSCT
WT.
INSIDE DIAMETER
INSULATION
INTERIOR
IRRIGATION
JOINT
LAMINATED
LAVATORY
MAXIMUM
MEDICINE CABINET
MECHANICAL
METAL
MANUFACTURER
MINIMUM
MISCELLANEOUS
MASONRY OPENING
MOUNTED
NORTH
NOT IN CONTRACT
NOT TO SCALE
OVERALL
ON CENTER
OUTSIDE DIAMETER
OPENING
OPPOSITE
PRE-CAST
PLATE
PLASTIC LAMINATE
PLASTER
PLYWOOD
PAIR
POINT
PAPER TOWEL DISPENSER
RECEPTACLE
RADIUS
ROOF DRAIN
REFERENCE
REFRIGERATOR
REINFORCED
REQUIRED
ROOM
ROUGH OPENING
RE-SAWN
REDWOOD
RAIN WATER LEADER
SOUTH
SOLID CORE
SEAT COVER DISPENSER
SCHEDULE
SOAP DISPENSER
SECTION
SHELF OR SHEET
SHOWER
SIMILAR
SPECIFICATION
SQUARE
STAINLESS STEEL
STATION
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
SYMMETRICAL
SHEET METAL
TOP OF CURB
TELEPHONE
TERRAZZO
TEMPERED GLASS
TONGUE AND GROOVE
THICK
TOP OF PAVEMENT
TOILET PAPER DISPENSER
TELEVISION
TOP OF WALL
TYPICAL
TOP OF
TOP OF PLATE
UNLESS OTHERWISE NOTED
URINAL
VERTICAL
VESTIBULE
VERIFY IN FIELD
PLUMBING VENT THRU ROOF
WEST
WITH
WATER CLOSET
WOOD
WITHOUT
WATERPROOF
WEAKENED PLANE JOINT
WAINSCOT
WEIGHT
General Notes
1. DIMENSIONS SHOWN ON THE FLOOR PLANS, SECTIONS AND DETAILS ARE TO FACE OF STUDS,
COLUMN GRID LINES AND FACE OF CONCRETE AND BLOCK WALLS, UNLESS OTHERWISE NOTED OR
SHOWN.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE PROCEEDING
WITH CONSTRUCTION.
3. ALL ITEMS ARE BASE BID UNLESS OTHERWISE NOTED OR SPECIFIED.
4. ALL DRAIN LINES WITHIN WALLS ARE TO BE WRAPPED IN SOUND INSULATION BATTS.
5. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL
KNOWLEDGE.
6. CONTRACTOR SHALL PROVIDE ACCESS PANELS REQUIRED BY THE PLUMBING, AIR CONDITIONING
AND OTHER INSTALLERS, AS REQUIRED BY CODE. ANY ACCESS PANEL IN A FIRE RATED WALL OR
CEILING SHALL HAVE THE SAME FIRE RATING AS THE WALL OR CEILING IN WHICH THEY OCCUR.
7. STRUCTURAL AND FIRE RESISTIVE INTEGRITY SHALL BE MAINTAINED AT PENETRATIONS FOR
MECHANICAL, PLUMBING, ELECTRICAL, AND COMMUNICATIONS PIPE, DUCT AND CONDUIT AS
INDICATED.
8. PROVIDE FIRE BLOCKING AT FLOOR, CEILING AND MID HEIGHT OF WALLS OVER 10'-0".
9. STUCCO, PLASTER AND GYPSUM BOARD SHALL TERMINATE WITH A "J" MOLDING WHERE THE EDGE IS
EXPOSED UNLESS NOTED OR SPECIFIED OTHERWISE.
10. A FLOOR OR LANDING NOT MORE THE 1/4" BELOW THE THRESHOLD IS REQUIRED AT EACH SIDE OF AN
EXIT DOOR.
11. BRAND OR TRADE NAME, SUBSTITUTIONS OF "EQUALS": REQUESTS FOR SUBSTITUTIONS OF AN ITEM AS
AN "EQUAL" TO ANY ITEM INDICATED OR SPECIFIED MUST BE INCLUDED AS A PART OF THE
CONTRACTOR'S BID PROPOSAL, AS SPECIFIED IN THE GENERAL CONDITIONS.
12. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC SCALE. DO NOT SCALE DRAWINGS.
13. IT SHOULD BE NOTED THAT WHILE EXISTING UTILITY DRAWINGS ARE AVAILABLE, THERE IS NO
ASSURANCE THAT ALL UTILITIES ARE SHOWN. THE CONTRACTOR SHALL PROCEED WITH CAUTION TO
INSURE THAT ALL UTILITIES ENCOUNTERED, WHETHER OR NOT OF RECORD, SHALL BE PROTECTED FROM
DAMAGE. THE CONTRACTOR SHALL ALSO TAKE PRECAUTIONS NECESSARY TO PROTECT HIMSELF AND
ALL EMPLOYEES FROM INJURY WHICH MAY BE CAUSED BY CONTACT WITH UTILITY SERVICES.
14. GYPSUM BOARD FOR FIRE RATED ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH CBC
CHAPTER 7.
15. DOOR HARDWARE SHALL BE LEVER TYPE.
16. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5
POUNDS FOR INTERIOR DOORS.
17. FIRE DAMPER ASSEMBLIES, INCLUDING SLEEVES AND INSTALLATION PROCEDURES SHALL BE
APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION.
18. INTERIOR FINISHES SHALL COMPLY WITH THE PROVISIONS OF CBC CHAPTER 8.
19. ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION.
20. ALL REQUIRED PERMITS MUST BE OBTAINED FROM FIRE PLAN CHECK BEFORE BUILDING IS OCCUPIED.
21. BUILDING NUMBERS SHALL BE EASILY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE
PROPERTY.
22. THE CONSTRUCTION, REMODEL, OR DEMOLITION OF A BUILDING SHALL COMPLY WITH THE
REQUIREMENTS OF THE CITY OF PLEASANTON, STANDARD SPEC'S, DETAIL AND CURRENT U.B.C.
EDITION AS CURRENTLY ADAPTED BY BUILDING DEPARTMENT.
23. THESE PLANS AND ALL WORK SHALL COMPLY WITH THE CALIFORNIA BUILDING STANDARDS CODE
FOUND IN THE STATE OF CALIFORNIA TITLE 24 CCR, AS AMENDED AND ADOPTED BY CITY OF
PLEASANTON.
24. CONTRACTOR SHALL THOROUGHLY COORDINATE ALL TRADES AS REQUIRED TO COMPLETE ALL
WORK INDICATED AND NECESSARY FOR THE PROJECT.
25. CONTRACTOR SHALL PROTECT EXISTING SITE FEATURES AND SHALL REPAIR OR REPLACE ALL ITEMS
DAMAGED DURING CONSTRUCTION.
26. EXIT SIGNS MUST BE INTERNALLY ILLUMINATED (UFC SEC. 1212.4 & CBC SEC.1006).
27. TWO SEPARATE POWER SUPPLIES SHALL BE PROVIDED FOR EXIT SIGNS PER(CBC SEC. 1006).
28. THE CONTRACTOR SHALL ENFORCE ALL SAFETY MEASURES. THE CONTRACTOR SHALL DESIGN,
CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND SHALL BE SOLELY
RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH
STANDARDS, LAWS AND REGULATION.
29. CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF CONSTRUCTION, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS
REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS.
30. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MONUMENTATION AND / OR BENCHMARKS
WHICH WILL BE DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH POINTS SHALL BE REFERENCED
AND REPLACED WITH APPROPRIATE MONUMENTATION BY A LICENSED LAND SURVEY OR REGISTERED
CIVIL ENGINEER AS REQUIRED BY THE LAND SURVEYOR'S ACT.
31. CONTRACTOR SHALL REPLACE IN KIND ANY TRAFFIC SENSORS DAMAGED DURING CONSTRUCTION.
32. PENETRATION OF FIRE RESISTIVE WALLS, FLOOR - CEILING ASSEMBLIES AND ROOF - CEILINGS SHALL BE
PROTECTED AS REQUIRED IN CBC SECTION 712 AND 713.
33. NO HAZARDOUS MATERIALS WILL BE USED OR STORED WITHIN THE BUILDING WHICH EXCEED THE
QUANTITIES SHOWN IN CBC.
34. WHEN SERVING MORE THAN 100 SPRINKLER HEADS, AUTOMATIC SPRINKLER SYSTEMS SHALL BE
SUPERVISED BY AN ARROVED CENTRAL PROGRAM OR REMOTE STATION SERVICE OR SHALL BE
PROVIDED WITH A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY
ATTENDED LOCATION.
6353 DEL CERRO BOULEVARD | SAN DIEGO, CA 92120 | 619.698.9177
www.jeffkatzarchitecture.com
DATE REV.
DESCRIPTION
06/15/18
FOR BID
CITY OF PLEASANTON
Department of Engineering
STEPHEN M.
KIRKPATRICK
CITY ENGINEER
NO. 53367
EXP. 6/30/19
Sheet Index
No.
Description
T-1
TITLE SHEET
T-2
GENERAL NOTES, ABBREVIATIONS, SYMBOLS
A1.0
A1.1
A1.2
A1.3
A2.1
A2.2
A3.1
A3.2
A7.5
A7.6
A7.7
A7.8
DEMO ROOF PLAN
DEMO ELEVATIONS
DEMO ELEVATIONS
DEMO VIEWS
ROOF PLAN
REPAIR VIEWS
BUILDING ELEVATIONS
BUILDING ELEVATIONS
PARAPET DETAILS
DETAILS
SCHEDULES
COLUMN DETAILS
Symbols
CG
FE
1
A101
GRID
DETAIL
BUILDING SECTION
INTERIOR ELEVATION
WALL TYPE
WINDOW TYPE
DOOR NUMBER
CONSTRUCTION NOTES
DATUM POINT
CORNER GUARD
FIRE EXTINGUISHER
CONTINUOUS, UNOBSTRUCTED AND
UNDIMINISHED PATH OF TRAVEL
INDICATES ACTIVE VIEW DIRECTION OF
SECTION
DETAIL CALLOUT
CITY OF PLEASANTON
PLEASANTON FIRE STATION NO. 4 REPAIRS, CIP NO. 11429
1600 OAK VISTA WAY, PLEASANTON, CA 94566
ENSFERDEYAAR.CKHI T
C018223
REN. 09/10/19
AT E OF CALIFORNI
DESIGN:
JK
CHECKED:
JK
DRAWN:
AR
SHEET TITLE:
GENERAL NOTES,
ABBREVIATIONS,
SYMBOLS
SCALE:
N.T.S.
Project Number: 170602
DATE:
2018-05-01
DWG NO.
T-2
2 OF 14
A
C
D
E
F
H
J
D1
A13.2
K
M
N
O
Q
R
12
3
4
5
6
7
8
9
B1
A7.5
B1
A13.1
B1
A7.5
632
225
TYP.
615
B1
A7.8
615
D1
A1.3
D2
A1.3
D3
A1.3
615
638
B3
A1.3
632
036
TYP.
B2
A1.3
10
11
12
A
B
CONSTRUCTION NOTES
036 REMOVE ALL EXISTING FOAM ROOFING SYSTEM
225 COLUMN BELOW, SEE EXTERIOR ELEVATIONS
615 REMOVE EXISTING PARAPET CAP. PROTECT EXISTING PARAPET FRAMING
IN PLACE, TYP. REFERENCE B1/A7.5
632 EXISTING STANDING SEAM METAL ROOF - PROTECT IN PLACE
638 EXISTING ROOF ACCESS HATCH - PROTECT IN PLACE
TYP.
B3
A7.5
B2
A1.3
G
D1
A13.1
K
L
O
P
S
NOTE:
REFERENCE A1.1 AND A1.2 FOR DEMO ELEVATIONS.
ALL DETAILS INDICATED ARE TYPICAL THROUGHOUT
12
3
4
6
8
9
B1
A13.2
10
11
12
6353 DEL CERRO BOULEVARD | SAN DIEGO, CA 92120 | 619.698.9177
www.jeffkatzarchitecture.com
DATE REV.
DESCRIPTION
06/15/18
FOR BID
CITY OF PLEASANTON
Department of Engineering
STEPHEN M.
KIRKPATRICK
CITY ENGINEER
NO. 53367
EXP. 6/30/19
CITY OF PLEASANTON
PLEASANTON FIRE STATION NO. 4 REPAIRS, CIP NO. 11429
1600 OAK VISTA WAY, PLEASANTON, CA 94566
ENSFERDEYAAR.CKHI T
C018223
REN. 09/10/19
AT E OF CALIFORNI
DESIGN:
JK
CHECKED:
JK
DRAWN:
AR
SHEET TITLE:
DEMO ROOF PLAN
SCALE:
1/8" = 1'-0"
Project Number: 170602
DATE:
2018-05-01
DWG NO.
A1.0
3 OF 14
T.O.PARAPET.
22' - 9"
T.O. PARAPET
16' - 6"
F.F.
0' - 0"
12
11
± 25'-9"
VIF
10
003
B1
TYP. A7.5
± 40'-10"
VIF
± 15'-6"
VIF
9
8
002
TYP.
± 7'-0"
VIF
± 16'-9"
VIF
6
5
4
3
21
± 19'-3"
VIF
± 34'-10"
VIF
± 41'-1"
VIF
± 18'-11"
VIF
T.O.PARAPET.
22' - 9"
T.O. PARAPET
16' - 6"
F.F.
0' - 0"
B1 NORTH_DEMO
A1.1 SCALE: 1/8" = 1'-0"
CONSTRUCTION NOTES
002 DEMO PARAPET TO EXTENTS SHOWN, REFERENCE DEMO DETAIL B1/A7.5
003 PROTECT EXISTING SIDING IN PLACE
NOTE:
REFERENCE A1.0 FOR DEMO ROOF PLAN .
REFERENCE A1.3 FOR DEMO VIEWS.
REFERENCE B1/A7.5 FOR DEMOLITION DETAILS .
T.O.PARAPET.
22' - 9"
T.O. PARAPET
16' - 6"
F.F.
0' - 0"
S
O
003
TYP.
± 23'-2 171/256"
VIF
K
G
B1
A7.5
± 72'-7"
VIF
± 17'-2"
VIF
BA
002
TYP.
± 21'-9 85/256"
VIF
F.F.
0' - 0"
D1 EAST_DEMO
A1.1 SCALE: 1/8" = 1'-0"
6353 DEL CERRO BOULEVARD | SAN DIEGO, CA 92120 | 619.698.9177
www.jeffkatzarchitecture.com
DATE REV.
DESCRIPTION
06/15/18
FOR BID
CITY OF PLEASANTON
Department of Engineering
STEPHEN M.
KIRKPATRICK
CITY ENGINEER
NO. 53367
EXP. 6/30/19
CITY OF PLEASANTON
PLEASANTON FIRE STATION NO. 4 REPAIRS, CIP NO. 11429
1600 OAK VISTA WAY, PLEASANTON, CA 94566
ENSFERDEYAAR.CKHI T
C018223
REN. 09/10/19
AT E OF CALIFORNI
DESIGN:
JK
CHECKED:
JK
DRAWN:
AR
SHEET TITLE:
DEMO ELEVATIONS
SCALE:
1/8" = 1'-0"
Project Number: 170602
DATE:
2018-05-01
DWG NO.
A1.1
4 OF 14
1
T.O. PLATE
25' - 0"
T.O.PARAPET.
22' - 9"
T.O. PARAPET
16' - 6"
3
± 19'-0"
VIF
± 15'-0"
VIF
6
B1
003 A7.5
TYP.
± 33'-3"
VIF
002
TYP.
± 15'-5"
VIF
± 21'-5"
VIF
8
9
± 10'-9"
VIF
± 16'-3"
VIF
± 6'-9"
VIF
F.F.
0' - 0"
± 40'-6"
VIF
10
11
12
± 26'-0"
VIF
± 15'-8"
VIF
B1 SOUTH ELEVATION
A1.2 SCALE: 1/8" = 1'-0"
CONSTRUCTION NOTES
002 DEMO PARAPET TO EXTENTS SHOWN, REFERENCE DEMO DETAIL B1/A7.5
003 PROTECT EXISTING SIDING IN PLACE
004 DEMO EXISTING WINDOW, SEE D3/A1.3 FOR EXTENTS
686 SEE A7.8 FOR COLUMN DETAILS
F.F.
0' - 0"
NOTE:
REFERENCE A1.0 FOR DEMO ROOF PLAN .
REFERENCE A1.3 FOR DEMO VIEWS.
REFERENCE B1/A7.5 FOR DEMOLITION DETAILS .
A
C
D
F
T.O.PARAPET.
22' - 9"
T.O. PARAPET
16' - 6"
003
TYP.
B1
A7.5
004
± 39'-4"
VIF
002
TYP.
± 17'-3"
VIF
± 19'-2"
VIF
HJ K
MN O
S
± 13'-6"
VIF
± 10'-9"
VIF
± 13'-4"
VIF
± 3'-6"
VIF
F.F.
0' - 0"
686
F.F.
0' - 0"
D1 WEST ELEVATION
A1.2 SCALE: 1/8" = 1'-0"
6353 DEL CERRO BOULEVARD | SAN DIEGO, CA 92120 | 619.698.9177
www.jeffkatzarchitecture.com
DATE REV.
DESCRIPTION
06/15/18
FOR BID
CITY OF PLEASANTON
Department of Engineering
STEPHEN M.
KIRKPATRICK
CITY ENGINEER
NO. 53367
EXP. 6/30/19
CITY OF PLEASANTON
PLEASANTON FIRE STATION NO. 4 REPAIRS, CIP NO. 11429
1600 OAK VISTA WAY, PLEASANTON, CA 94566
ENSFERDEYAAR.CKHI T
C018223
REN. 09/10/19
AT E OF CALIFORNI
DESIGN:
JK
CHECKED:
JK
DRAWN:
AR
SHEET TITLE:
DEMO ELEVATIONS
SCALE:
1/8" = 1'-0"
Project Number: 170602
DATE:
2018-05-01
DWG NO.
A1.2
5 OF 14

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Opportunity History Complete View Original Synopsis Presolicitation Apr 04, 2019 2:10 pm Changed

Department of the Army

Bid Due: 7/11/2019

Opportunity History Complete View Original Synopsis Presolicitation May 07, 2019 5:37 pm Changed

Department of the Army

Opportunity History Original Synopsis Mar 19, 2019 1:06 pm Solicitation Number : MAF-0319-2019

Department of Energy

Opportunity History Complete View Original Synopsis Presolicitation Apr 22, 2019 11:58 am Changed

Department of the Interior

Bid Due: 8/07/2019