| Z--LITTLE CALUMET RIVER, PUMP STATION REHABILITATIONS, AT FOREST AVENUE AND TAPPER AVENUE, HAMMOND, INDIANA |
| Program Summary |
 |
| Title: |
Z--LITTLE CALUMET RIVER, PUMP STATION REHABILITATIONS, AT FOREST AVENUE AND TAPPER AVENUE, HAMMOND, INDIANA |
| GovCB Opps ID : |
ADP12105011020001081 |
| Document Type: |
Solicitation (Modified) |
| FSC Code: |
Z - Maintenance, Repair or Alteration of Real Property
|
| Set Aside: |
N/A |
| Solicitation No.: |
W912P6-08-R-0001 |
| Source: |
https://www.fbo.gov/?s=opportunity&mode=form&id=202c7ddde3d0c26d14196c2ab5f16b3a&tab=cor... |
Place of Performance: |
|
Posted Date: |
May 11, 2008 |
| Last Update: |
May 11, 2008 |
| Due Date: |
Apr 15, 2008 |
|
| Description |
 |
Z--LITTLE CALUMET RIVER, PUMP STATION REHABILITATIONS, AT FOREST AVENUE AND TAPPER AVENUE, HAMMOND, INDIANA Solicitation Number: W912P6-08-R-0001 Agency: Department of the Army Office: U.S. Army Corps of Engineers Location: US Army Corps of Engineer, Chicago
- Print
- Link
Copy or Bookmark this Page Copy the url below for a direct link to this page.
Bookmark this page by right-clicking here and choosing "Bookmark This Link..."
|
Opportunity History
|
Solicitation Number:
W912P6-08-R-0001
Notice Type:
Solicitation
Synopsis:
Added: March 28, 2008
By way of this Announcement, the Chicago District Corps of Engineers issues a Pre-solicitation Notice for its LITTLE CALUMET RIVER, HAMMOND INDIANA project. The Contractor will be required to provide all necessary facilities, plants, labor, transpor tation, materials and equipment to work at the FOREST AVEUNE AND TAPPER AVENEUE PUMP STATIONS. FOREST AVENUE PUMP STATION -1) Pumps and Motors: Rebuild both Fairbanks Morse, vertical wet well pumps, Model 145710(WC), S/N 724465 and 724466 and Fairbanks Mo rse, 20 HP motors S/N 590926 and 590927. 2) Pump Discharge System: Furnish and install new flap valves and replace existing discharge piping. Clean, paint and reuse wall pipes. Furnish and install knife gate valve with operator in discharges lines. 3) Ve ntilation: a. Replace motor floor fan, gravity damper and screen; b. Furnish and install new motor room supply air wall louver, screen and motorized damper; c. Replace ductwork for wet well area ventilation; and d. Replace supply air wall louvers, scre ens and duct to wet well areas. 4) Trash Rack: Replace existing trash rack with new trash rack.; 5) Electrical: a. Replace existing electrical distribution equipment, including panel boards, circuit breakers and motor starters for pumps, heating and vent ilating equipment and other loads. The new system shall include a motor control center and variable frequency drives. b. Furnish and install outdoor generator hookup for connection to future generator. c. Furnish and install two solid state pump control- telemetry units and submersible level transmitters for primary control. Remote monitoring will be installed in future by owner. Existing solid state controller shall remain for use by Hammond Sanitary District. d. Replace all existing interior and exter ior lighting fixtures as shown. e. Replace existing lighting transformer and lighting panel. f. Replace all receptacles. Furnish and install GFCI receptacles in areas designated on the drawings. g. Replace all existing conduits and power and control ca bles in the pump station unless otherwise shown. Provide all new conduits and power and control cables as required for all new and existing equipment; 6) Structural: a. Rehabilitate existing floor areas as necessary to meet requirements of rebuilt pumps and motors and new motor control center. b. Replace existing access covers with new pressure rated, sealed covers on the pump station discharge box and wet well by-pass chamber as shown. c. Expand the discharge box size for the installation of flap valve s. d. Replace the pump and base bend supports. 7) Gravity By-pass: Replace existing 30 INCH flap valve on gravity by-pass. 8) Miscellaneous: a. Replace existing ladders with new units, where shown. b. Clean and paint existing equipment to remain. c. Furnish and install perimeter fencing. d. Remove trees as shown. e. Remove existing float tube and furnish and install two new cast iron FLOAT TUBES for pressure transmitter and level controls. f. Furnish and install air release valve on discharge box. TAPPER AVENUE PUMP STATION 1) Pumps and Motors: Rebuild both Fairbanks Morse, Vertical wet Well Pumps, Model 18 5710(WC) S/N 727118 and 727119, and Fairbanks Morse, 40 HP motors S/N 591655 and unknown. 2) Pump Discharge System: Replace flap valves an d existing discharge piping. Clean, paint and reuse wall pipes. Furnish and install knife gate valve with operator in discharges lines. 3) Ventilation: a. Replace motor floor fan, gravity damper and screen; b. Furnish and install new motor room supply ai r wall louver, screen and motorized damper. c. Replace ductwork below motor floor level for wet well area ventilation. d. Replace supply air wall louvers, and ductwork to wet well areas. 4) Trash Rack: Replace existing trash rack with new trash rack. 5) Electrical: a. Replace existing electrical distribution equipment, including panel boards, circuit breakers and motor starters for pumps, heating and ventilati ng equipment and other loads. The new system shall include a motor control center and variable frequency drives. b. Upgrade service to 480 volt phase. c. Furnish and install outdoor generator hookup for connection to future generator. d. Furnish and in stall solid state pump control-telemetry unit and submersible level transmitter for primary and back-up control. Replace existing float controller for backup control and turn existing float controller over to Hammond Sanitary District for use as spare pa rts. Remote monitoring will be installed in future by owner. Existing solid state controller shall remain for use by Hammond Sanitary District. e. Replace all existing interior and exterior lighting fixtures as shown. f. Replace existing lighting trans former and lighting panel. g. Replace all receptacles. Install GFCI receptacles in areas designated on the drawings. h. Replace all existing conduits and power and control cables in the pump station unless otherwise shown. Provide all new conduits and power and control cables as required for all new and existing equipment. 6) Structural: a. Rehabilitate existing floor areas as necessary to meet requirements of rebuilt pumps and motors and new motor control center. b. Replace existing access covers wit h new pressure rated, sealed covers on the pump station discharge box. c. Replace pump and base bend supports. 7) Miscellaneous: a. Replace existing ladders with new units, where shown. b. Clean and paint existing equipment to remain. c. Clean and pai nt existing float tube. d. Furnish and install new access walkway and steps to the pump station. e. Furnish and install cast iron FLOAT TUBE for pressure transmitter. f. Furnish and install air release valve on discharge box. g. Furnish and install ent rance deck. The Classification Code for this procurement is North American Industry System (NAICS) 237110, with a business size in dollars of $31.0 Million. COMPETITION IS UNRESTRICTED TO BUSINESS SIZE. Interested Offerors can download the Request for Pr oposal Package from the Internet Site https://www.fedteds.gov/fedteds/start.nsf/frm.vendorlogin?openform&SolicitationNumber=W912P6-08-R-0001.; The solicitation will be available on the Internet on or before 15 April 2008. The due date for proposals will b e on or about 16 May 2008, at 4:30 PM Chicago Local Time. In order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the Central Contractor Registration (CCR). Contractors can acces s the CCR for free at http//www.ccr.gov. Request for solicitation packages made by telephone, fax or e-mail will not be honored.
Solicitation 1
Sensitive/Secure Package:
no
Posted Date:
April 15, 2008
Description: Plans for Little Calumet River Pump Station Rehabilition
Description: Specifications for Little Calumet River Pump Station Rehabilition
Modification 2
Sensitive/Secure Package:
no
Description: AMD 0001 LITTLE CALUMET RIVER, PUMP STATION 2(A) REHABILITATION, HAMMOND, INDIANA
Contracting Office Address:
US Army Corps of Engineers, Chicago, 111 N. Canal, Suite 600, Chicago, IL 60606
Place of Performance:
US Army Corps of Engineers, Chicago 111 N. Canal, Suite 600, Chicago IL
60606
Primary Point of Contact.:
Anita R. Simpkins
Phone: 312-846-5372 Fax: 312-886-5475
|
General Information
Notice Type:
Solicitation
Original Posted Date:
March 28, 2008
Response Date:
April 15, 2008
Original Response Date:
April 15, 2008
Archiving Policy:
Automatic, on specified date
Original Archive Date:
June 14, 2008
Archive Date:
June 14, 2008
Classification Code:
Z -- Maintenance, repair, and alteration of real property
NAICS Code:
237 -- Heavy and Civil Engineering Construction/237110 -- Water and Sewer Line and Related Structures Construction
|
|
|