Y--Bonneville 2nd Powerhouse DC and Preferred ACUpgrade
Program Summary
Title: Y--Bonneville 2nd Powerhouse DC and Preferred ACUpgrade
GovCB Opps ID : ADP12147011820000977
Document Type: Solicitation (Modified)
FSC Code: Y - Construction of Structures and Facilities
Set Aside: N/A
Solicitation No.: W9127N-08-R-0023
Source: https://www.fbo.gov/?s=opportunity&mode=form&id=2ebe274f5e528a457a4dd4a2f2b409d1&tab=cor...
Place of
Performance:

Posted Date:
Jun 28, 2008
Last Update: Jun 28, 2008
Due Date: Jul 02, 2008

Description
Y--Bonneville 2nd Powerhouse DC and Preferred ACUpgrade
Solicitation Number: W9127N-08-R-0023
Agency: Department of the Army
Office: U.S. Army Corps of Engineers
Location: U.S. Army Engineer District, Portland
  • Print
  • Link
    Copy or Bookmark this Page

    Copy the url below for a direct link to this page.

    Bookmark this page by right-clicking here and choosing "Bookmark This Link..."

Opportunity History
Solicitation Number:
W9127N-08-R-0023
Notice Type:
Solicitation
Synopsis:
Added: April 4, 2008
Description
The U.S. Army Corps of Engineers (USACE), Northwest Division, Portland District (NWP) has a competitive requirement for the Bonneville 2nd Powerhouse DC and Preferred AC. This solicitation will result in a single award firm fixed price contract. This contract will install two completely independent DC and Preferred AC (battery derived) systems within Bonneville 2nd Powerhouse. Each independent DC system will include a new 125VDC battery, 125VDC battery charger, 125VDC service panel, and 125VDC battery monitoring system with computer. There will also be a third 125VDC battery charger installed that will act as a swing charger, serving backup to either DC system. Each 125VDC service panel will have new dedicated feeds installed to sub panels to establish a truly redundant system in order to eliminate virtually all single points of failure modes. Each independent Preferred AC system will include a new 120VAC inverter, 480/120 single phase transformer to serve as bypass to the inverter, manual bypass switches external to the inverter for maintenance purposes, and new 120VAC service panels. Each 120VAC service panel will have new dedicated feeds installed to sub panels to establish a truly redundant system in order to eliminate virtually all single points of failure modes. Respective 125VDC and 120VAC panels will be installed within a battery switchboard lineup. Each battery switchboard will also contain annunciation, protective relaying of the DC system, and metering of DC voltage,current and impedance to ground quantities. Detailed specification will be inclusive in the solicitation package. A Site Safety and Health Officer (SSHO) shall be provided for all new contracts with this District. For this project, the person that will act as the SSHO is required to have a minimum of 3 years safety work with similar projects and a 30 Hour OSHA construction safety class (or equivalent) taken within the last 3 years. The SSHO may have no other duties for this work except function as the on-site CQC Manager. Competition for this procurement is full and open. The NAICS Code is 2358210 and the small business size standard is 13 million. Large business will be required to submit a small business subcontracting plan. The Magnitude of Construction is between $1,000,000.00 and $5,000,000.00. This procurement will be a Request for Proposal (RFP) and a firm-Fixed-price contract will be negotiated as a result of this procurement. The solicitation for this project will be issued in electronic format. The solicitation will be made available on FedTeds website after it is issued. Interested parties must be registered on Fedteds (www.fedteds.gov) to download the solicitation information. In order to conduct business with the Department of Defense contractors must be enroll on the Central Contracting Register (CCR) www.ccr.gov. Offerors are responsible for checking the referenced page for any update(s). The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website. The solicitation issue date is anticipated to on or about April 25, 2006 with a close date on or about May 25, 2008; the tentative award date of on or about June 15, 2008. A lowest priced technically acceptable method will be used to evaluate proposals. The evaluation will include 3 factors to include price as a non-technical factor. The Evaluation Factors that may be considered are: Relevant Experience and Past Performance. The Request for Proposal will contain complete evaluation criteria. Technical Point of Contact is Brandt Bannister at Brandt.D.Bannister@usace.army.mil. Administrative matters related to the contract can be addressed by e-mail to Mark Heiller at mark.f.heiller@usace.army.mil.
All inquiries regarding this solicitation are to be submitted via Bidder Inquiry. Telephone and email inquiries will not be accepted. Bidder Inquiry is a web-based program that allows bidders to post questions regarding the solicitation and to view all questions by other bidders and answers by USACE. Bidder Inquiry instructions will be detailed in the solicitation.
Please consult the list of document viewers if you cannot open a file.
Solicitation 1
Sensitive/Secure Package:
no
Type:
Solicitation
Posted Date:
June 2, 2008
Amendment 1
Sensitive/Secure Package:
no
Type:
Mod/Amendment
Posted Date:
June 12, 2008
Amendment 2
Sensitive/Secure Package:
no
Type:
Mod/Amendment
Posted Date:
June 26, 2008
Contracting Office Address:
Portland District, US Army Corps of Engineers, Contracting Division (CENWP-CT_, P.O. Box 2946, Portland, OR 97208-2946
Place of Performance:
Portland District, US Army Corps of Engineers Contracting Division (CENWP-CT-C) P.O. Box 2946 Portland OR 97208-2946 US
Point of Contact(s):
General Information
Notice Type:
Solicitation
Original Posted Date:
April 4, 2008
Posted Date:
June 26, 2008
Response Date:
July 2, 2008
Original Response Date:
July 2, 2008
Archiving Policy:
Automatic, on specified date
Original Archive Date:
July 24, 2008
Archive Date:
July 24, 2008
Original Set Aside:
N/A
Set Aside:
N/A
Classification Code:
Y -- Construction of structures and facilities
NAICS Code:
238 -- Specialty Trade Contractors/238210 -- Electrical Contractors and Other Wiring Installation Contractors




Home - Browse By Keyword - Browse By Region - About Us - Privacy Policy - Terms of Use - Sitemap - Help
Copyright 2004 GovCB.com All rights reserved
4855 River Green Pkwy, Suite 510, Duluth, GA 30096