Government contract and bid
About Us Sitemap Help Sign In
Typhoon Trio+ Variable Mode Imager
Program Summary
Title: Typhoon Trio+ Variable Mode Imager
GovCB Opps ID : ADP12149330060001058
Document Type: Combined Synopsis/Solicitation
FSC Code: 66 - Instruments and Laboratory Equipment
Set Aside: N/A
Solicitation No.: LEG593
Source: https://www.fbo.gov/?s=opportunity&mode=form&id=1a8bd6cb7599654bf13c2a27b062fb09&tab=cor...
Place of
Performance:

Posted Date:
Jul 01, 2008
Last Update: Jul 01, 2008
Due Date: Jul 10, 2008

Description
Typhoon Trio+ Variable Mode Imager
Solicitation Number: LEG593
Agency: Department of Health and Human Services
Office: National Institutes of Health
Location: National Institute on Aging, IRP, BRC
  • Print
  • Link
    Copy or Bookmark this Page

    Copy the url below for a direct link to this page.

    Bookmark this page by right-clicking here and choosing "Bookmark This Link..."

Opportunity History
  • Original Synopsis
    Jul 01, 2008
    7:00 pm
Solicitation Number:
LEG593
Notice Type:
Combined Synopsis/Solicitation
Synopsis:
Added: Jul 01, 2008 10:59 am
The National Institute on Aging, IRP, intends to negotiate and award a purchase order on a noncompetitive basis with GE Healthcare Bio-Sciences Corp., Piscataway, NJ for a Typhoon Trio+ Variable Mode Imager, # 63005589 including Typhoon Trio+ Scanner, 6 standard emission filters (526SP, 520BP340, 555DF20, 580DF30, 610DF30, 670DF30), 7 user-selectable pixel size (10, 25, 50, 100, 200, 500, 1000 microns), 3 laser lines for excitation (488,532,633 nm), scanner control software (Windows XP), Single PC License for ImageQuant TL software, user guide, Fluorescence Imaging Technical Manual, microarray slide tray (2 slides), workstation scanner with monitor, #28408678 with inside delivery. Only one responsible source and no other supplies or services will satisfy agency requirements, 41 U.S.C. 253 (c)(1), FAR 6.302-1(b)(1). The cited authority is applicable because GE Healthcare is the only source that can fulfill the requirements of this contract. The Typhoon Trio Plus is the only general purpose, fill size gel and blot imager which is cap microarray imaging up to 30 bar-coded slides each in separate data files in one run with Typhoon multislide tray. The Typhoon uses Image Quant TL software for data analysis providing compatibility and continuity with all other data generated using this software program. Typhoon Trio Plus provides three high power excitation sources with excitation lines at 633 nm for scanning storage phosphor screens and red-excited fluorescent samples, 532 nm for scanning green-excited fluorescent samples 488nm for scanning chemifluorescent samples and blue excited fluorescent samples. Simultaneous dual excitation with 532nm & 633nm for fast Cy3/Cy5 scanning can be performed. Typhoon Tri Plus includes 6 fluorescence emission filters that are automatically selected by protocol. Additional filters can be substituted and added up to a maximum of 13 in the instrument at one time. Filters are stored internally and are registered guaranteeing filter in method is filter selected for operation. Typhoon Trio Plus scanning protocols can be linked to allow automatic scanning of up to four fluorescent dyes in one sample. The Typhoon Trio Plus system has two objectives permitting the excitation source to be focused at two heights to allow optimal scanning of different thickness samples such as membranes, microplates and sandwich gels. The typhoon Trio Plus system is capable of scanning storage phosphor screens, fluorescent DNA and protein gels, chemifluorescent DNA/RNA and protein blots and chemiluminescent Western blots, all in one system. Multiple radioactive samples can be simultaneously exposed to multiple screens for rapid parallel processing and high throughput. A linear dynamic range of 5 orders of magnitude on Typhoon Trio Plus permits simultaneous quantification of strong and weak signals and allows for wider latitude in exposure times. The Typhoon Trio Plus has three dichroic beamsplitters for channel separation with negligible loss of sensitivity. User selectable spatial resolution over a wide range (10,25,50,100,200,500,1000um) to fit with experimental requirements from fast pre-scans to high resolution applications. This acquisition is being conducted under Simplified Acquisition procedures and is exempt from the requirements of Far, Part 6, Competition Requirement. Award will be made on an all or none basis to the lowest priced, technically acceptable source.
Contracting Office Address:
251 Bayview Blvd, Room 04C009
Baltimore, Maryland 21224
Place of Performance:
251 Bayview Blvd
Baltimore, Maryland 21224
United States
Primary Point of Contact.:
Patricia L Meise
Phone: 410-558-8043
Fax: 410-558-8319
General Information
Notice Type:
Combined Synopsis/Solicitation
Posted Date:
July 1, 2008
Response Date:
July 10, 2008
Archiving Policy:
Automatic, 15 days after response date
Archive Date:
July 25, 2008
Original Set Aside:
N/A
Set Aside:
N/A
Classification Code:
66 -- Instruments & laboratory equipment
NAICS Code:
423 -- Merchant Wholesalers, Durable Goods/423450 -- Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers




Home - Browse By Keyword - Browse By Region - About Us - Privacy Policy - Terms of Use - Sitemap - Help
Copyright 2004 GovCB.com All rights reserved