| Program Summary |
 |
| Title: |
61--TRANSFORMERS |
| GovCB Opps ID : |
ADP12024775780000446 |
| Document Type: |
Presolicitation Notice |
| FSC Code: |
61 - Electric Wire, and Power and Distribution Equipment
|
| NAICS Code: |
423610 - Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers |
| Solicitation No.: |
M6740008T0092 |
| Source: |
http://www2.fbo.gov/spg/DON/USMC/M67400/M6740008T0092/SynopsisP.html |
Posted Date: |
Feb 08, 2008 |
| Last Update: |
Feb 08, 2008 |
| Due Date: |
Feb 14, 2008 |
|
| Description |
 |
General Information
| Document Type: |
Presolicitation Notice |
| Solicitation Number: |
M6740008T0092 |
| Posted Date: |
Feb 07, 2008 |
| Original Response Date: |
Feb 14, 2008 |
| Current Response Date: |
Feb 14, 2008 |
| Original Archive Date: |
Mar 14, 2008 |
| Current Archive Date: |
Mar 14, 2008 |
| Classification Code: |
61 -- Electric wire & power & distribution equipment |
Contracting Office Address
M67400 MARINE CORPS REGIONAL CONTRACTING OFFICE FAR EAST PSC 557 BOX 2000, FPO AP 96379
Description
This is a combined synopsis / solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice.    This procurement is not a small business set-aside; any responsible source may submit an offer.    This announcement constitutes the only solicitation; proposals are being requested and a separate written solicitation will not be issued.    Solicitation number M67400-08-T-0092 applies and is issued as a Request for Quotation.    This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-13 and Defense Acquisition Circular 91-13.    The NAICS code is 423610.    The agency need is for: ITEM NO      SUPPLIES/SERVICES      QUANTITY      UNIT      UNIT PRICE 0001                                            1      Each            TRANSFORMER FFP PAD-MOUNTED; THREE-PHASE, NEMA C57.12.26 AND AS SPECIFIED HEREIN, LIQUID INSULATED (NO PCB's BY JEGS REQUIREMENTS, SEE 6 BELOW), 45 kVA, 13,800 V DELTA PRI. (95 kV BIL), DEAD FRONT, RADIAL FEED, 208 Y/120 V SEC.    1. COMPARTMENTS:    A. THE HIGH AND LOW-VOLTAGE COMPARTMENTS SHALL BE SEPARATED BY STEEL ISOLATING BARRIERS EXTENDING THE FULL HEIGHT AND DEPTH OF THE COMPARTMENTS.    B. COMPARTMENT DOORS: HINGED LIFT-OFF TYPE WITH STOP IN OPEN POSITION AND THREE-POINT LATCHING. 2. HIGH VOLTAGE:    A. 15 kV-200 A BUSHING WELLS.    B. 15 kV-200 A LOADBREAK INSERTS (IEEE STD. 386).    C. 15 kV-200 A OIL-IMMERSED LOADBREAK SWITCH.    D. BAYONET TYPE, OIL-IMMERSED, EXPULSION FUSES IN SERIES WITH OIL-IMMERSED, PARTIAL-RANGE, CURRENT-LIMITING FUSES. COORDINATE TRANSFORMER PROTECTION WITH EXPULSION FUSE CLEARING LOW-CURRENT FAULTS AND CURRENT-LIMITING FUSE CLEARING HIGH-CURRENT FAULTS BEYOND THE INTERRUPTING RATING OF THE EXPULSION FUSE.    E. PARKING STANDS.    F. GROUND PAD. 3. LOW VOLTAGE:    A. BUSHINGS WITH NEMA 4-HOLE SPADE TERMINALS.    B. ACCESSORIES: DRAIN VALVE WITH SAMPLER, FILL PLUG, PRESSURE RELIEF DEVICE, LIQUID LEVEL GAUGE, PRESSURE VACUUM GAUGE AND DIAL TYPE THERMOMETER WITH MAXIMUM TEMPERATURE INDICATOR.    C. GROUND PAD. 4. TRANSFORMER:    A. LIQUID INSULATED, 60 Hz, 65 DEGREES C RISE, SELF-COOLED TYPE.    B. TAP CHANGER SHALL BE EXTERNALLY OPERATED, WITH FOUR 2.5 PERCENT FULL CAPACITY TAPS, TWO ABOVE AND TWO BELOW RATED PRIMARY VOLTAGE.    C. AUDIBLE SOUND LEVEL SHALL BE 51 DECIBELS OR LESS.    D. TRANSFORMER SHALL INCLUDE LIFTING LUGS AND PROVISIONS FOR JACKING UNDER BASE. THE TRANSFORMER BASE CONSTRUCTION SHALL BE SUITABLE FOR USING ROLLERS OR SKIDDING IN ANY DIRECTION. PROVIDE TRANSFORMER TOP WITH AN ACCESS HANDHOLE. THE TRANSFORMER SHALL HAVE AN INSULATED LOW-VOLTAGE NEUTRAL BUSHING WITH NEMA 4-HOLE SPADE TERMINAL, AND WITH REMOVABLE GROUND STRAP. 5. THE INSULATING LIQUID SHALL BE LESS FLAMMABLE PER NFPA 70 AND FM P7825, HAVING A FIRE POINT NOT LESS THAN 300 DEGREES C PER ASTM D 92 AND DIELECTRIC STRENGTH NOT LESS THAN 33 kV PER ASTM D 877. THE FLUID SHALL BE A BIODEGRADABLE INSULATING AND COOLING LIQUID, UL CLASSIFIED AND FM APPROVED AS "LESS-FLAMMABLE" FLUID, MEETING THE FOLLOWING PROPERTIES:    A. POUR POINT: ASTM D 97, LESS THAN MINUS 15 DEGREES C.    B. AQUATIC BIODEGRADATION: EPA 712-C-98-075, 100%.    C. TROUT TOXICITY: OECD TEST 203, ZERO MORTALITY OF EPA 600/4-90/027F, PASS. 6. PCB CONTENT: THE MANUFACTURER MUST CERTIFY THAT THE TRANSFORMER DOES NOT CONTAIN ANY PCB's. THERE IS TO BE NO DETECTABLE LEVEL OF PCB's AT A DETECTION LIMIT OF LESS THAN 0.1 (ZERO POINT ONE) ppm. THIS LIMIT IS A JEGS (JAPAN ENVIRONMENTAL GOVERNING STANDARDS) REQUIREMENT THAT APPLIES TO MARINE CORPS BASES JAPAN. AN ACCEPTABLE STANDARD TEST METHOD IS ASTM D4059. 7. NAMEPLATE: IEEE C57.12.00 AND WITH "PCB CONTENT DATA (LESS THAN 0.1 ppm)" AND "MANUFACTURER'S NAME AND TYPE OF FLUID". 8. PAINT BASE, CABINET AND TANK MUNSELL 7GY3.29/1.5 GREEN. THE PAINT COATING SYSTEM SHALL COMPLY WITH NEMA C57.12.29. 9. ROUTINE AND OTHER TESTS (IEEE C57.12.00): COLD RESISTANCE MEASUREMENTS, PHASE RELATION, RATIO, NO-LOAD LOSSES AND EXCITATION CURRENT, LOAD LOSSES AND IMPEDANCE VOLTAGE, DIELECTRIC (IMPULSE, APPLIED VOLTAGE AND INDUCED VOLTAGE) AND LEAK. THE FOLLOWING IS TO BE PROVIDED ALONG WITH THE OFFER:    1. PCB CONTENT CERTIFICATION.    2. OUTLINE DRAWING OF THE TRANSFORMER WITH DEVICES INDICATED.    3. NAMEPLATE DATA. ITEM NO      SUPPLIES/SERVICES      QUANTITY      UNIT      UNIT PRICE 0002                                          1      Each            TRANSFORMER FFP TRANSFORMER, PAD-MOUNTED; THREE-PHASE, NEMA C57.12.26 AND AS SPECIFIED HEREIN, LIQUID INSULATED (NO PCB's BY JEGS REQUIREMENTS, SEE 6 BELOW), 500 kVA, 13,800 V DELTA PRI. (95 kV BIL), DEAD FRONT, RADIAL FEED, 208 Y/120 V SEC. SEE THE LONG DESCRIPTION. LONG DESCRIPTION: 1. COMPARTMENTS:    A. THE HIGH AND LOW-VOLTAGE COMPARTMENTS SHALL BE SEPARATED BY STEEL ISOLATING BARRIERS EXTENDING THE FULL HEIGHT AND DEPTH OF THE COMPARTMENTS.    B. COMPARTMENT DOORS: HINGED LIFT-OFF TYPE WITH STOP IN OPEN POSITION AND THREE-POINT LATCHING. 2. HIGH VOLTAGE:    A. 15 kV-200 A BUSHING WELLS.    B. 15 kV-200 A LOADBREAK INSERTS (IEEE STD. 386).    C. 15 kV-200 A OIL-IMMERSED LOADBREAK SWITCH.    D. BAYONET TYPE, OIL-IMMERSED, EXPULSION FUSES IN SERIES WITH OIL-IMMERSED, PARTIAL-RANGE, CURRENT-LIMITING FUSES. COORDINATE TRANSFORMER PROTECTION WITH EXPULSION FUSE CLEARING LOW-CURRENT FAULTS AND CURRENT-LIMITING FUSE CLEARING HIGH-CURRENT FAULTS BEYOND THE INTERRUPTING RATING OF THE EXPULSION FUSE.    E. PARKING STANDS.    F. GROUND PAD. 3. LOW VOLTAGE:    A. BUSHINGS WITH NEMA 10-HOLE SPADE TERMINALS.    B. ACCESSORIES: DRAIN VALVE WITH SAMPLER, FILL PLUG, PRESSURE RELIEF DEVICE, LIQUID LEVEL GAUGE, PRESSURE VACUUM GAUGE AND DIAL TYPE THERMOMETER WITH MAXIMUM TEMPERATURE INDICATOR.    C. GROUND PAD. 4. TRANSFORMER:    A. LIQUID INSULATED, 60 Hz, 65 DEGREES C RISE, SELF-COOLED TYPE.    B. TAP CHANGER SHALL BE EXTERNALLY OPERATED, WITH FOUR 2.5 PERCENT FULL CAPACITY TAPS, TWO ABOVE AND TWO BELOW RATED PRIMARY VOLTAGE.    C. AUDIBLE SOUND LEVEL SHALL BE 56 DECIBELS OR LESS.    D. TRANSFORMER SHALL INCLUDE LIFTING LUGS AND PROVISIONS FOR JACKING UNDER BASE. THE TRANSFORMER BASE CONSTRUCTION SHALL BE SUITABLE FOR USING ROLLERS OR SKIDDING IN ANY DIRECTION. PROVIDE TRANSFORMER TOP WITH AN ACCESS HANDHOLE. THE TRANSFORMER SHALL HAVE AN INSULATED LOW-VOLTAGE NEUTRAL BUSHING WITH NEMA 10-HOLE SPADE TERMINAL, AND WITH REMOVABLE GROUND STRAP. 5. THE INSULATING LIQUID SHALL BE LESS FLAMMABLE PER NFPA 70 AND FM P7825, HAVING A FIRE POINT NOT LESS THAN 300 DEGREES C PER ASTM D 92 AND DIELECTRIC STRENGTH NOT LESS THAN 33 kV PER ASTM D 877. THE FLUID SHALL BE A BIODEGRADABLE INSULATING AND COOLING LIQUID, UL CLASSIFIED AND FM APPROVED AS "LESS-FLAMMABLE" FLUID, MEETING THE FOLLOWING PROPERTIES:    A. POUR POINT: ASTM D 97, LESS THAN MINUS 15 DEGREES C.    B. AQUATIC BIODEGRADATION: EPA 712-C-98-075, 100%.    C. TROUT TOXICITY: OECD TEST 203, ZERO MORTALITY OF EPA 600/4-90/027F, PASS. 6. PCB CONTENT: THE MANUFACTURER MUST CERTIFY THAT THE TRANSFORMER DOES NOT CONTAIN ANY PCB's. THERE IS TO BE NO DETECTABLE LEVEL OF PCB's AT A DETECTION LIMIT OF LESS THAN 0.1 (ZERO POINT ONE) ppm. THIS LIMIT IS A JEGS (JAPAN ENVIRONMENTAL GOVERNING STANDARDS) REQUIREMENT THAT APPLIES TO MARINE CORPS BASES JAPAN. AN ACCEPTABLE STANDARD TEST METHOD IS ASTM D4059. 7. NAMEPLATE: IEEE C57.12.00 AND WITH "PCB CONTENT DATA (LESS THAN 0.1 ppm)" AND "MANUFACTURER'S NAME AND TYPE OF FLUID". 8. PAINT BASE, CABINET AND TANK MUNSELL 7GY3.29/1.5 GREEN. THE PAINT COATING SYSTEM SHALL COMPLY WITH NEMA C57.12.29. 9. ROUTINE AND OTHER TESTS (IEEE C57.12.00): COLD RESISTANCE MEASUREMENTS, PHASE RELATION, RATIO, NO-LOAD LOSSES AND EXCITATION CURRENT, LOAD LOSSES AND IMPEDANCE VOLTAGE, DIELECTRIC (IMPULSE, APPLIED VOLTAGE AND INDUCED VOLTAGE) AND LEAK. THE FOLLOWING IS TO BE PROVIDED ALONG WITH THE OFFER:    1. PCB CONTENT CERTIFICATION.    2. OUTLINE DRAWING OF THE TRANSFORMER WITH DEVICES INDICATED.    3. NAMEPLATE DATA. ITEM NO      SUPPLIES/SERVICES      QUANTITY      UNIT      UNIT PRICE 0003                                      1,000      Feet            CABLE FFP CABLE, POWER, ELECTRICAL; 15 KV, TYPE "MV-105", UL LISTED, # 2, SINGLE COPPER CONDUCTOR, 220 MIL EPR INSULATION (133% INSULATION LEVEL), EXTRUDED CONDUCTOR SHIELD, EXTRUDED INSULATION SHIELD, COPPER TAPE INSULATION SHIELD. SEE THE LONG DESCRIPTION. LONG DESCRIPTION: PVC JACKET, IDENTIFICATION ON THE JACKET, # 2 AWG SIZE. SOUTHWIRE CT1-13ET OR EQUAL.CABLE, POWER, ELECTRICAL; 15 KV, TYPE "MV-105", UL LISTED, # 2, SINGLE COPPER CONDUCTOR, 220 MIL EPR INSULATION (133% INSULATION LEVEL), EXTRUDED CONDUCTOR SHIELD, EXTRUDED INSULATION SHIELD, COPPER TAPE INSULATION SHIELD. ITEM NO      SUPPLIES/SERVICES      QUANTITY      UNIT      UNIT PRICE 0004                                          6      Kit            CONNECTOR ELBOW FFP CONNECTOR,    ELBOW, 200 AMP LOADBREAK , 15KV 1/0    CABLE ITEM NO      SUPPLIES/SERVICES      QUANTITY      UNIT      UNIT PRICE 0005                                        15      Each            TERMINAL LUG FFP TERMINAL, LUG; TAP, BOLTED, BRONZE, SSTL. HARDWARE, UP TO TWO CABLES (TWO EYEBOLTS) TO 3/4" THK FLAT COPPER PAD, # 1/0 SOL.-500 MCM CABLE SIZE. ITEM NO      SUPPLIES/SERVICES      QUANTITY      UNIT      UNIT PRICE 0006                                          9      Kit            CONNECTOR ELBOW FFP CONNECTOR, LOADBREAK ELBOW KIT; 200 A - 15 kV CLASS, W/ TEST POINT, INDIVIDUALLY PACKAGED, 0.700 - 0.910" INSUL. DIA., # 1/0 AWG STR. OR COMPRESSED OR # 2/0 AWG COMPACT CONDUCTOR. ITEM NO      SUPPLIES/SERVICES      QUANTITY      UNIT      UNIT PRICE 0007                                          2      Each            TRANSFORMER FFP TRANSFORMER, PAD-MOUNTED; THREE-PHASE, NEMA C57.12.26 AND AS SPECIFIED HEREIN, LIQUID INSULATED (NO PCB's BY JEGS REQUIREMENTS, SEE 6 BELOW), 112.5 kVA, 13,800 V DELTA PRI. (95 kV BIL), DEAD FRONT, RADIAL FEED, 208 Y/120 V SEC. SEE THE LONG DESCRIPTION. LONG DESCRIPTION: 1. COMPARTMENTS:    A. THE HIGH AND LOW-VOLTAGE COMPARTMENTS SHALL BE SEPARATED BY STEEL ISOLATING BARRIERS EXTENDING THE FULL HEIGHT AND DEPTH OF THE COMPARTMENTS.    B. COMPARTMENT DOORS: HINGED LIFT-OFF TYPE WITH STOP IN OPEN POSITION AND THREE-POINT LATCHING. 2. HIGH VOLTAGE:    A. 15 kV-200 A BUSHING WELLS.    B. 15 kV-200 A LOADBREAK INSERTS (IEEE STD. 386).    C. 15 kV-200 A OIL-IMMERSED LOADBREAK SWITCH.    D. BAYONET TYPE, OIL-IMMERSED, EXPULSION FUSES IN SERIES WITH OIL-IMMERSED, PARTIAL-RANGE, CURRENT-LIMITING FUSES. COORDINATE TRANSFORMER PROTECTION WITH EXPULSION FUSE CLEARING LOW-CURRENT FAULTS AND CURRENT-LIMITING FUSE CLEARING HIGH-CURRENT FAULTS BEYOND THE INTERRUPTING RATING OF THE EXPULSION FUSE.    E. PARKING STANDS.    F. GROUND PAD. 3. LOW VOLTAGE:    A. BUSHINGS WITH NEMA 4-HOLE SPADE TERMINALS.    B. ACCESSORIES: DRAIN VALVE WITH SAMPLER, FILL PLUG, PRESSURE RELIEF DEVICE, LIQUID LEVEL GAUGE, PRESSURE VACUUM GAUGE AND DIAL TYPE THERMOMETER WITH MAXIMUM TEMPERATURE INDICATOR.    C. GROUND PAD. 4. TRANSFORMER:    A. LIQUID INSULATED, 60 Hz, 65 DEGREES C RISE, SELF-COOLED TYPE.    B. TAP CHANGER SHALL BE EXTERNALLY OPERATED, WITH FOUR 2.5 PERCENT FULL CAPACITY TAPS, TWO ABOVE AND TWO BELOW RATED PRIMARY VOLTAGE.    C. AUDIBLE SOUND LEVEL SHALL BE 55 DECIBELS OR LESS.    D. TRANSFORMER SHALL INCLUDE LIFTING LUGS AND PROVISIONS FOR JACKING UNDER BASE. THE TRANSFORMER BASE CONSTRUCTION SHALL BE SUITABLE FOR USING ROLLERS OR SKIDDING IN ANY DIRECTION. PROVIDE TRANSFORMER TOP WITH AN ACCESS HANDHOLE. THE TRANSFORMER SHALL HAVE AN INSULATED LOW-VOLTAGE NEUTRAL BUSHING WITH NEMA 4-HOLE SPADE TERMINAL, AND WITH REMOVABLE GROUND STRAP. 5. THE INSULATING LIQUID SHALL BE LESS FLAMMABLE PER NFPA 70 AND FM P7825, HAVING A FIRE POINT NOT LESS THAN 300 DEGREES C PER ASTM D 92 AND DIELECTRIC STRENGTH NOT LESS THAN 33 kV PER ASTM D 877. THE FLUID SHALL BE A BIODEGRADABLE INSULATING AND COOLING LIQUID, UL CLASSIFIED AND FM APPROVED AS "LESS-FLAMMABLE" FLUID, MEETING THE FOLLOWING PROPERTIES:    A. POUR POINT: ASTM D 97, LESS THAN MINUS 15 DEGREES C.    B. AQUATIC BIODEGRADATION: EPA 712-C-98-075, 100%.    C. TROUT TOXICITY: OECD TEST 203, ZERO MORTALITY OF EPA 600/4-90/027F, PASS. 6. PCB CONTENT: THE MANUFACTURER MUST CERTIFY THAT THE TRANSFORMER DOES NOT CONTAIN ANY PCB's. THERE IS TO BE NO DETECTABLE LEVEL OF PCB's AT A DETECTION LIMIT OF LESS THAN 0.1 (ZERO POINT ONE) ppm. THIS LIMIT IS A JEGS (JAPAN ENVIRONMENTAL GOVERNING STANDARDS) REQUIREMENT THAT APPLIES TO MARINE CORPS BASES JAPAN. AN ACCEPTABLE STANDARD TEST METHOD IS ASTM D4059. 7. NAMEPLATE: IEEE C57.12.00 AND WITH "PCB CONTENT DATA (LESS THAN 0.1 ppm)" AND "MANUFACTURER'S NAME AND TYPE OF FLUID". 8. PAINT BASE, CABINET AND TANK MUNSELL 7GY3.29/1.5 GREEN. THE PAINT COATING SYSTEM SHALL COMPLY WITH NEMA C57.12.29. 9. ROUTINE AND OTHER TESTS (IEEE C57.12.00): COLD RESISTANCE MEASUREMENTS, PHASE RELATION, RATIO, NO-LOAD LOSSES AND EXCITATION CURRENT, LOAD LOSSES AND IMPEDANCE VOLTAGE, DIELECTRIC (IMPULSE, APPLIED VOLTAGE AND INDUCED VOLTAGE) AND LEAK. THE FOLLOWING IS TO BE PROVIDED ALONG WITH THE OFFER:    1. PCB CONTENT CERTIFICATION.    2. OUTLINE DRAWING OF THE TRANSFORMER WITH DEVICES INDICATED.    3. NAMEPLATE DATA. ITEM NO      SUPPLIES/SERVICES    QUANTITY      UNIT      UNIT PRICE 0008                                        1                      Each            TRANSFORMER FFP TRANSFORMER, PAD-MOUNTED; THREE-PHASE, NEMA C57.12.26 AND AS SPECIFIED HEREIN, LIQUID INSULATED (NO PCB's BY JEGS REQUIREMENTS, SEE 6 BELOW), 225 kVA, 13,800 V DELTA PRI. (95 kV BIL), DEAD FRONT, RADIAL FEED, 208 Y/120 V SEC. SEE THE LONG DESCRIPTION. LONG DESCRIPTION: 1. COMPARTMENTS:    A. THE HIGH AND LOW-VOLTAGE COMPARTMENTS SHALL BE SEPARATED BY STEEL ISOLATING BARRIERS EXTENDING THE FULL HEIGHT AND DEPTH OF THE COMPARTMENTS.    B. COMPARTMENT DOORS: HINGED LIFT-OFF TYPE WITH STOP IN OPEN POSITION AND THREE-POINT LATCHING. 2. HIGH VOLTAGE:    A. 15 kV-200 A BUSHING WELLS.    B. 15 kV-200 A LOADBREAK INSERTS (IEEE STD. 386).    C. 15 kV-200 A OIL-IMMERSED LOADBREAK SWITCH.    D. BAYONET TYPE, OIL-IMMERSED, EXPULSION FUSES IN SERIES WITH OIL-IMMERSED, PARTIAL-RANGE, CURRENT-LIMITING FUSES. COORDINATE TRANSFORMER PROTECTION WITH EXPULSION FUSE CLEARING LOW-CURRENT FAULTS AND CURRENT-LIMITING FUSE CLEARING HIGH-CURRENT FAULTS BEYOND THE INTERRUPTING RATING OF THE EXPULSION FUSE.    E. PARKING STANDS.    F. GROUND PAD. 3. LOW VOLTAGE:    A. BUSHINGS WITH NEMA 6-HOLE SPADE TERMINALS.    B. ACCESSORIES: DRAIN VALVE WITH SAMPLER, FILL PLUG, PRESSURE RELIEF DEVICE, LIQUID LEVEL GAUGE, PRESSURE VACUUM GAUGE AND DIAL TYPE THERMOMETER WITH MAXIMUM TEMPERATURE INDICATOR.    C. GROUND PAD. 4. TRANSFORMER:    A. LIQUID INSULATED, 60 Hz, 65 DEGREES C RISE, SELF-COOLED TYPE.    B. TAP CHANGER SHALL BE EXTERNALLY OPERATED, WITH FOUR 2.5 PERCENT FULL CAPACITY TAPS, TWO ABOVE AND TWO BELOW RATED PRIMARY VOLTAGE.    C. AUDIBLE SOUND LEVEL SHALL BE 55 DECIBELS OR LESS.    D. TRANSFORMER SHALL INCLUDE LIFTING LUGS AND PROVISIONS FOR JACKING UNDER BASE. THE TRANSFORMER BASE CONSTRUCTION SHALL BE SUITABLE FOR USING ROLLERS OR SKIDDING IN ANY DIRECTION. PROVIDE TRANSFORMER TOP WITH AN ACCESS HANDHOLE. THE TRANSFORMER SHALL HAVE AN INSULATED LOW-VOLTAGE NEUTRAL BUSHING WITH NEMA 6-HOLE SPADE TERMINAL, AND WITH REMOVABLE GROUND STRAP. 5. THE INSULATING LIQUID SHALL BE LESS FLAMMABLE PER NFPA 70 AND FM P7825, HAVING A FIRE POINT NOT LESS THAN 300 DEGREES C PER ASTM D 92 AND DIELECTRIC STRENGTH NOT LESS THAN 33 kV PER ASTM D 877. THE FLUID SHALL BE A BIODEGRADABLE INSULATING AND COOLING LIQUID, UL CLASSIFIED AND FM APPROVED AS "LESS-FLAMMABLE" FLUID, MEETING THE FOLLOWING PROPERTIES:    A. POUR POINT: ASTM D 97, LESS THAN MINUS 15 DEGREES C.    B. AQUATIC BIODEGRADATION: EPA 712-C-98-075, 100%.    C. TROUT TOXICITY: OECD TEST 203, ZERO MORTALITY OF EPA 600/4-90/027F, PASS. 6. PCB CONTENT: THE MANUFACTURER MUST CERTIFY THAT THE TRANSFORMER DOES NOT CONTAIN ANY PCB's. THERE IS TO BE NO DETECTABLE LEVEL OF PCB's AT A DETECTION LIMIT OF LESS THAN 0.1 (ZERO POINT ONE) ppm. THIS LIMIT IS A JEGS (JAPAN ENVIRONMENTAL GOVERNING STANDARDS) REQUIREMENT THAT APPLIES TO MARINE CORPS BASES JAPAN. AN ACCEPTABLE STANDARD TEST METHOD IS ASTM D4059. 7. NAMEPLATE: IEEE C57.12.00 AND WITH "PCB CONTENT DATA (LESS THAN 0.1 ppm)" AND "MANUFACTURER'S NAME AND TYPE OF FLUID". 8. PAINT BASE, CABINET AND TANK MUNSELL 7GY3.29/1.5 GREEN. THE PAINT COATING SYSTEM SHALL COMPLY WITH NEMA C57.12.29. 9. ROUTINE AND OTHER TESTS (IEEE C57.12.00): COLD RESISTANCE MEASUREMENTS, PHASE RELATION, RATIO, NO-LOAD LOSSES AND EXCITATION CURRENT, LOAD LOSSES AND IMPEDANCE VOLTAGE, DIELECTRIC (IMPULSE, APPLIED VOLTAGE AND INDUCED VOLTAGE) AND LEAK. THE FOLLOWING IS TO BE PROVIDED ALONG WITH THE OFFER:    1. PCB CONTENT CERTIFICATION.    2. OUTLINE DRAWING OF THE TRANSFORMER WITH DEVICES INDICATED.    3. NAMEPLATE DATA. Estimated shipping via ground to: Defense Logistics Agency Defense Distribution Center Tracy Depot, Bldg 30, CCP 25600 S. Chrisman Rd. Tracy, CA 95376 The Government intends to make a single award to the responsible offeror whose offer is the most advantageous to the Government considering technical acceptability, price, and delivery time. The following Provisions apply to this acquisition: FAR 52.212-1 Instructions to Offerors-Commercial Items (Oct 2000), FAR 52.212-2 Evaluation-Commercial Items (Jan 1999, applies with paragraph (a) completed as follows: The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Technical Acceptability, Price, and Delivery Time, FAR 52.212-3 Offeror Representations and Certification Commercial Items (Jun 2003), FAR 52.212-4 Contract Terms and Conditions Commercial Items (Feb 2002), FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders !    Commercial Items (Jun 2003), FAR 52.232-33 Payment by Electronic Funds Transfer (May 1999), FAR 52.247-34 F.O.B. Destination (Nov 1991). Responsible offeror must be active in the Central Contractor Registration on in accordance with DFARS 252.204-7004 (NOV 2001).    DUNS, TIN, and CAGE Code must be written on submitted quote.    Payment shall be made electronically by DFAS Yokota Japan.    Full text of http://farsite.hill.af.mil. The following information must be provided with this quotation: Commercial and government entity code (Cage). Taxpayer identification number (Tin).      Data universal numbering system (Duns).      Estimated Delivery Date: GSA contract number if applicable Remit to Address Offers can be faxed to 011816117450959, emailed to william.figueroa@usmc.mil, or mailed to the Regional Contracting Office, PSC 557 BOX 2000, FPO AP 96379-2000.    Offers must be received no later than 14 Feb 2008, 6:00 PM Eastern Standard Time.    Questions may be addressed to Sgt William Figueroa, by email at:william.figueroa@usmc.mil.       
Point of Contact
Sgt William Figueroa 011-81-611-745-8695 GySgt De Leon 011-81-611-745-5294 benny.deleon@usmc.mil
|
|