Title: TEST KITS: ANTIBODY AGRICULTURE
GovCB Opps ID : ADP12109581660000953
FSC Code: 65 - Medical, Dental, and Veterinary Equipment and Supplies
Solicitation No.: B1E08240
Source: https://www.moolb.mo.gov/BidList/biddetail.asp?rtype=commo&which=B1E08240+++&bidExpired=0
Posted Date:
May 16, 2008
Due Date: May 21, 2008

Description

To respond to this bid electronically, you must be logged in with a Premium Registration.

Bid Number: B1E08240 Status: Open
Agency: OFFICE ADMINISTRATION-OPER Total Bid Lines: 9
Description: TEST KITS: ANTIBODY AGRICULTURE Closing Date:
Closing Time:
5/21/2008
2:00pm CENTRAL

The information on this page provides a summary of the requirements for this bid. The official bid document includes the applicable requirements, detailed specifications, and Terms and Conditions.   In the event of any discrepancy, the official bid document will govern.

To access the official bid document, click on this link:B1E08240 . A page will open with links to download the official bid document in Microsoft Word or PDF format.



IF RESPONDING ELECTRONICALLY THROUGH THE ON-LINE BIDDING/VENDOR
REGISTRATION SYSTEM WEBSITE, IN ADDITION TO COMPLETING THE ON-LINE
PRICING, THE PREMIUM REGISTERED BIDDER SHOULD COMPLETE AND SEND THE
PRICING PAGE FOR RENEWAL PERIOD PRICING, EACH EXHIBIT, AND ANY OTHER
INFORMATION CONCERNING THE BID AS AN ATTACHMENT TO THE ELECTRONIC
RESPONSE.

Line Commodity
001 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
AGID EQUINE INFECTIOUS ANEMIA TEST KIT
THE KIT MUST HAVE ANTIGENS DERIVED FROM CELL CULTURE ADAPTED
VIRUS AND FROM RECOMBINANT P26 PROTEIN. THE KITS MUST
BE USDA APPROVED AND MUST CONTAIN ALL REAGENTS
NECESSARY TO RUN THE TEST EXCEPT THOSE NEEDED TO MAKE
THE AGAR. THE KIT MUST CONTAIN PRESERVED, HIGHLY PURIFIED
ANTIGEN, WHICH ELIMINATES NONSPECIFIC PRECIPITIN LINES.
THE KIT MUST CONTAIN EIA POSITIVE CONTROL SERUM. THE
PRECIPITIN LINES FORMED WITH THE TEST SERUMS MUST BE CLEAR
AND DISTINCT. THE KIT EXPIRATION DATE MUST BE AT LEAST SIX (6)
MONTHS FROM THE DATE RECEIVED BY THE STATE AGENCY AND MUST
INCLUDE INSTRUCTIONS WITH EACH KIT. THE KIT MUST PRODUCE CLEAR
AND DISTINCT LINES ON THE NATIONAL VETERINARY SERVICES
LABORATORY'S (NVSL) YEARLY EIA CHECK TEST SET.
THE KIT'S ANTIGEN AND POSITIVE CONTROL SHALL BE SHIPPED READY TO USE.
IDEXX DIASYSTEMS EIA AGID OR APPROVED EQUIVALENT.

BIDDER TO STATE FOLLOWING:

BRAND: __________________________________

STOCK NO.: _______________________________

NO. OF SAMPLES TESTED PER KIT: ________________

SPECIFY FORMAT OF KIT (PLATE OR STRIP): __________

002 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
BOVINE LEUKEMIA VIRUS ANTIBODY TEST KIT (ELISA)
THE KIT MUST BE A USDA LICENSED KIT WHICH DETECTS
ANTIBODIES TO THE BLV GLYCOPROTEIN (GP51) IN BOVINE
SERUM. THE KIT MUST BE SUPPLIED IN A MICROTITER (96 WELL)
STRIP WELL FORMAT AND MUST CONTAIN A POSITIVE AND NEGATIVE
CONTROL PLUS ALL OTHER REAGENTS NECESSARY TO PERFORM THE
TESTS. THE KIT MUST NOT REQUIRE A VERIFICATION TEST FOR SCREEN
POSITIVE SAMPLES. THE KIT EXPIRATION DATE MUST BE AT LEAST SIX (6)
MONTHS FROM DATE RECEIVED BY THE STATE AGENCY. THE CONTRACTOR
MUST SUPPLY FREE SOFTWARE TO INTERPRET THE TEST RESULTS. SOFTWARE
MUST IDENTIFY SAMPLES AS POSITIVE OR NEGATIVE WITH THE CAPABILITY
TO PRINT THE OPTICAL DENSITY READINGS AS WELL AS S/P OR S/N
VALUES DEPENDING ON KIT PROTOCOLS. SOFTWARE MUST BE ABLE TO
INTERFACE WITH CURRENT STATE ANIMAL HEALTH LABORATORY EQUIPMENT.
VMRD BOVINE LEUKEMIA VIRUS ANTIBODY TEST KIT OR EQUIVALENT.

BIDDER TO STATE FOLLOWING:

BRAND: __________________________________

STOCK NO.: _______________________________

NO. OF SAMPLES TESTED PER KIT: ________________

SPECIFY FORMAT OF KIT (PLATE OR STRIP): __________

003 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
MYCOBACTERIUM PARATUBERCULOSIS TEST KIT (JOHNES)
THE KIT MUST BE A USDA LICENSED KIT WHICH DETECTS
ANTIBODIES TO MYCOBACTERIUM PARATUBERCULOSIS IN BOVINE
SERUM OR PLASMA. THE KIT MUST BE SUPPLIED IN A
MICROTITER (96 WELL) STRIP WELL FORMAT AND MUST CONTAIN
A POSITIVE AND NEGATIVE CONTROL PLUS ALL OTHER REAGENTS
NECESSARY TO PERFORM THE TESTS. THE KIT EXPIRATION DATE
MUST BE AT LEAST SIX (6) MONTHS FROM DATE RECEIVED BY THE
STATE AGENCY. THE CONTRACTOR MUST SUPPLY FREE SOFTWARE TO
INTERPRET THE TEST RESULTS. SOFTWARE MUST IDENTIFY SAMPLES
AS POSITIVE OR NEGATIVE WITH THE CAPABILITY TO PRINT THE OPTICAL
DENSITY READING AS WELL AS THE S/P OR S/N VALUES DEPENDING
ON KIT PROTOCOLS. SOFTWARE MUST BE ABLE TO INTERFACE WITH
CURRENT STATE ANIMAL HEALTH LABORATORY EQUIPMENT.
IDEXX HERDCHEK M.PT. OR APPROVED EQUIVALENT.

BIDDER TO STATE FOLLOWING:

BRAND: __________________________________

STOCK NO.: _______________________________

NO. OF SAMPLES TESTED PER KIT: ________________

SPECIFY FORMAT OF KIT (PLATE OR STRIP): __________

004 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
BRUCELLA ABORTUS ANTIBODY TEST KIT (PCFIA) -
PARTICLE CONCENTRATION FLUORESCENCE IMMUNOASSAY

BIDDER TO STATE FOLLOWING:

BRAND: __________________________________

STOCK NO.: _______________________________

NO. OF SAMPLES TESTED PER KIT: ________________

SPECIFY FORMAT OF KIT (PLATE OR STRIP): __________

005 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
PORCINE REPRODUCTIVE AND RESPIRATORY SYNDROME VIRUS ANTIBODY KIT
THE KIT MUST BE A USDA LICENSED KIT WHICH DETECTS
ANTIBODIES TO PORCINE REPRODUCTIVE AND RESPIRATORY
SYNDROME IN SWINE SERUM. THE KIT MUST BE SUPPLIED IN
A MICROTITER (96 WELL) STRIP WELL FORMAT AND MUST CONTAIN
A POSITIVE AND NEGATIVE CONTROL PLUS ALL OTHER REAGENTS
NECESSARY TO PERFORM THE TESTS. THE KIT EXPIRATION DATE
MUST BE AT LEAST SIX (6) MONTHS FROM DATE RECEIVED BY THE
STATE AGENCY. THE CONTRACTOR MUST SUPPLY FREE SOFTWARE
TO INTERPRET THE TEST RESULTS. SOFTWARE MUST IDENTIFY SAMPLES
AS POSITIVE OR NEGATIVE WITH THE CAPABILITY TO PRINT THE
OPTICAL DENSITY READINGS AS WELL AS THE S/P OR S/N VALUES
DEPENDING ON KIT PROTOCOLS. SOFTWARE MUST BE ABLE TO
INTERFACE WITH CURRENT STATE ANIMAL HEALTH LABORATORY
EQUIPMENT.
IDEXX HERDCHEK PRRS VIRUS ANTIBODY TEST KIT 2XR OR EQUIVALENT.

BIDDER TO STATE FOLLOWING:

BRAND: __________________________________

STOCK NO.: _______________________________

NO. OF SAMPLES TESTED PER KIT: ________________

SPECIFY FORMAT OF KIT (PLATE OR STRIP): __________

006 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
PSEUDORABIES VIRUS ANTIBODY TEST KIT
THE KIT MUST BE A USDA LICENSED KIT WHICH DETECTS
ANTIBODIES TO PORCINE PSEUDORABIES VIRUS IN SWINE
SERUM, PLASMA AND MEAT EXUDATE. THE KIT MUST BE
SUPPLIED IN A MICROTITER (96 WELL) STRIP WELL FORMAT
AND MUST CONTAIN A POSITIVE AND NEGATIVE CONTROL PLUS
ALL OTHER REAGENTS NECESSARY TO PERFORM THE TESTS.
THE KIT EXPIRATION DATE MUST BE AT LEAST SIX (6) MONTHS
FROM DATE RECEIVED BY THE STATE AGENCY. THE CONTRACTOR
MUST SUPPLY FREE SOFTWARE TO INTERPRET THE TEST RESULTS.
SOFTWARE MUST IDENTIFY SAMPLES AS POSITIVE OR NEGATIVE
WITH THE CAPABILITY TO PRINT THE OPTICAL DENSITY READINGS
AS WELL AS S/P OR S/N VALUES DEPENDING ON KIT
PROTOCOLS. SOFTWARE MUST BE ABLE TO INTERFACE WITH
CURRENT STATE ANIMAL HEALTH LABORATORY EQUIPMENT.
IDEXX HERDCHEK PSEUDORABIES VIRUS GB ANTIBODY TEST KIT OR
EQUIVALENT.

BIDDER TO STATE FOLLOWING:

BRAND: __________________________________

STOCK NO.: _______________________________

NO. OF SAMPLES TESTED PER KIT: ________________

SPECIFY FORMAT OF KIT (PLATE OR STRIP): __________

007 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
1ST RENEWAL PERIOD: JULY 1, 2009 THROUGH JUNE 30, 2010
RENEWAL OPTION PERCENTAGE PRICE ADJUSTMENT
BIDDER MUST IDENTIFY BELOW BY CHECKING APPROPRIATELY AS AN INCREASE OR
DECREASE
MAXIMUM INCREASE: OR MINIMUM DECREASE:

008 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
2ND RENEWAL PERIOD: JULY 1, 2010 THROUGH JUNE 30, 2011
RENEWAL OPTION PERCENTAGE PRICE ADJUSTMENT
BIDDER MUST IDENTIFY BELOW BY CHECKING APPROPRIATELY AS AN INCREASE OR
DECREASE
MAXIMUM INCREASE: OR MINIMUM DECREASE:

009 49599 - LABORATORY/FIELD EQUIPMENT/SUPPLIES: BIOLOGY, BOTANY, GEOLOG
3RD RENEWAL PERIOD: JULY 1, 2011 THROUGH JUNE 30, 2012
RENEWAL OPTION PERCENTAGE PRICE ADJUSTMENT
BIDDER MUST IDENTIFY BELOW BY CHECKING APPROPRIATELY AS AN INCREASE OR
DECREASE
MAXIMUM INCREASE: OR MINIMUM DECREASE:

For more information, please contact SCHULTE, TERI at teri.schulte@oa.mo.gov