Government contract and bid
About Us Sitemap Help Sign In
StealthStation Treon
Program Summary
Title: StealthStation Treon
GovCB Opps ID : ADP12145275420000860
Document Type: Presolicitation (Modified)
FSC Code: 65 - Medical, Dental, and Veterinary Equipment and Supplies
Set Aside: N/A
Solicitation No.: spm2d108R0018
Source: https://www.fbo.gov/?s=opportunity&mode=form&id=d8e643e02ebd97836a5eb14654637675&tab=cor...
Place of
Performance:

Posted Date:
Jun 26, 2008
Last Update: Jun 26, 2008
Due Date: Jul 02, 2008

Description
StealthStation Treon
Solicitation Number: spm2d108R0018
Agency: Defense Logistics Agency
Office: DLA Acquisition Locations
Location: Defense Supply Center Philadelphia - Medical
  • Print
  • Link
    Copy or Bookmark this Page

    Copy the url below for a direct link to this page.

    Bookmark this page by right-clicking here and choosing "Bookmark This Link..."

Opportunity History
Solicitation Number:
spm2d108R0018
Notice Type:
Presolicitation
Synopsis:
Added: May 21, 2008 3:28 pm Modified: Jun 26, 2008 8:52 amTrack Changes
No NSN is listed for the following items

This brand Name or equal requirement is for the Medtronic StealthStation Treon system and accessories listed below.


QTY 1 Stealth Station Treon- Medtronic Item number 9732532

QTY 1 Treon Axiem Add-On- Medtronic Item number 9733389

QTY 1 Cranial Software- Medtronic Item number 9730896

QTY 1 Cranial Instrument Set passive- Medtronic Item number 9730550

QTY 1 Accessory, Mayfield double star mount adapter- Medtronic Item number 960-535

QTY 1 Microscope Probe- Medtronic Item number 9730285

QTY 1 Cranial Instrument Set including cranial touc-N-Go registration Kit - Medtronic Item number 9732176

QTY 1 Instrument Axiem click and point Probe- Medtronic Item number 9660237

QTY 1 Cranial instrument set navigus Passive Biopsy Kit- Medtronic Item number 9733265

The Walter Reed Army Medical Center s Neurosurgery Department has a requirement to upgrade their current Image Guided Surgery System (IGS). The Image Guided Surgery System will be used on the following anatomical areas: brain, spine, orthopedic and Ear/Nose/Throat (ENT). The IGS should incorporate computerized technologies of multi-dimensional (minimum 3-D) and navigation to enable neurosurgeons to precisely plan, re-plan and visualize a surgical procedure in real-time. The IGS should be capable of localizing or pinpointing a given target within the treatment area without damaging healthy tissue, muscle, nerves or blood vessels.The IGS System should be able to take images from the following imaging sources: X-Ray, Computerized Tomography (CT), and Magnetic Resonance Imaging (MRI) and Ultrasound. The IGS system should be able to take the images from traditional imaging sources and be able to transform them into precise three-dimensional images (3D). The 3D images should be capable of being changed, manipulated and merged both before the surgical procedure as well as during the procedure.The IGS system should be capable of analyzing pre-operative diagnostic scans (i.e. CT, MRI) of the patient, and then be able to translate the information into precise 3D images that allow the surgeon to map the safest, least invasive path to the target site. In the operating suite, the IGS system shall be capable of producing 3D real-time images of the procedure while in progress. The IGS system shall be capable of merging images form multiple sources and manipulate pictures thus, allowing surgeons to view them from various angles. The IGS system should be able to incorporate the use of standard surgical instruments. The images and exact location of the instruments should be readily seen in 3D and in real-time during surgery with the use of the IGS system.
The IGS system should have software applications for the brain, spinal, orthopedic, and ENT surgeries. The software should be capable of allowing instant access to a patient s imaging (i.e. CT, MR, etc.) history. This retrieved information should be able to be used to assist in making treatment decisions.The IGS should consist of an electromagnetic tracking technology that uses a single-coil engineering to generate an electromagnetic field around the patient s target anatomy that can be tracked to triangulate the positioning of instruments and patient-tracking devices. The system should be user-friendly with easy to use features to allow the surgeon to concentrate on patient care and not use of the equipment.


The statutory authority permitting other than full and open competition is
section 4202 of the Clinger-Cohen Act as implemented by FAR 13.501, using the test program for commercial items. The applicable NAICS Code is 339113 with a size standard of 500 employees. This notice is for informational purposes only; NO FORMAL SOLICITATION WILL BE ISSUED as a result of this announcement. Interested parties may identify their interest and submit technical information in response to this notice via email to the address listed below, no later than July 2, 2008 at 5:00 PM EST. A determination by the Government not to complete this proposed contract is entirely in the discretion of the Government. If no responses are received by July 2, 2008 at 5:00 PM EST, a sole source contract with Metronic Inc will be pursued. The POC for this notice is Thomas Walsh at (215) 737-5097, FAX (215) 737-5097, email: Thomas.walsh@DLA.MIL
Contracting Office Address:
700 Robbins Avenue
Philadelphia, Pennsylvania 19111-5096
Place of Performance:
Walter Reed Army Medical Center
Washington , District of Columbia 22060-5116
United States
Primary Point of Contact.:
thomas walsh,
contracting spec
Phone: 215 737 5097
Fax: 215 737 5752
General Information
Notice Type:
Presolicitation
Original Posted Date:
May 21, 2008
Posted Date:
June 26, 2008
Response Date:
Jul 02, 2008 5:00 pm
Original Response Date:
June 5, 2008
Archiving Policy:
Automatic, 15 days after response date
Original Archive Date:
June 20, 2008
Archive Date:
July 17, 2008
Original Set Aside:
N/A
Set Aside:
N/A
Classification Code:
65 -- Medical, dental & veterinary equipment & supplies
NAICS Code:
339 -- Miscellaneous Manufacturing/339113 -- Surgical Appliance and Supplies Manufacturing




Home - Browse By Keyword - Browse By Region - About Us - Privacy Policy - Terms of Use - Sitemap - Help
Copyright 2004 GovCB.com All rights reserved
4855 River Green Pkwy, Suite 510, Duluth, GA 30096