Added: Sep 18, 2008 2:35 pm
Modified: Sep 22, 2008 4:53 pm
Track Changes
MODIFICATION NOTICE: Bids are being solicited under solicitation number W68MX382315255. This announcement constitutes the only solicitation; bids are being requested and a written solicitation will not be issued. The solicitation is issued as an invitation for bids (IFB), unless otherwise indicated herein. If your company can provide the product/services listed on the solicitation and comply with all of the solicitation instructions, please respond to this notice. To view the specifications, please go to www.FedBid.com and reference Buy No. 93486_02.
GSA Schedule Bids Only: Sellers bidding on this opportunity MUST have the items requested on an existing GSA Schedule. The Schedule must either be in the Seller's name or the Seller must be able to document its ability to act as an agent of a partner's Schedule. Sellers may offer Open Market items only in accordance with the approved Terms and Conditions of their respective GSA Schedule AND upon approval from the soliciting Contracting Officer. Information regarding GSA Schedules can be found at www.GSA.gov.
This requirement is a [ Small Business ] set-aside and only qualified sellers may submit bids. The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2008-09-27 12:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com. FOB Destination shall be Tacoma, WA 98431
The USA ACA Fort Lewis requires the following items, Meet or Exceed, to the following:
LI 001, G-57-2 DESCRIPTION Free Standing Horseshoe shape work area with Peninsula : 8'6" x 13'6" x 8' Modular Desks Qty 1 48 X 30 X 29 Left upright should be a full upright with a 30" foot/Right upright should be transitional with a 24" footQty 1 36 X 30 X 29 Left and right upright should be transitional 24" footQty 1 30 X 30 X 29 Left and right upright should be transitional 24" footQty 1 54 X 30 X 29 Left upright should be transitional with a 24" foot /Right upright should be a full upright with a 30" footQty 2 48 X 48 X 30 X 30 Curved Corner/ Left and right upright should be transitional 24" footQty 1 48 X 24 Free standing peninsula CHARACTERISTICS: Worksurface shall consist of complete steel base unit and high pressure laminate top. Worksurface shall be available as a self-supporting unit (freestanding) which includes two (2) uprights (legs) with tubular feet and a 12", 26 or 32 modesty panel (back panel). Uprights shall be constructed of 16 and 20 gauge steel with fully radiused leading edge. Modesty panel shall be constructed of 20 gauge steel and includes cable access ports which correspond to cable access ports located in the desktop laminate. Partial modesty panel shall be available to provide minimum clearance of 16" (applicable to 29" high worksurface) to allow for ventilation, base plate or raceway accommodation. Corner Worksurfaces and transition connectors shall be available as freestanding units. A full depth leg design and full height modesty panel design shall be available to address privacy and aesthetic requirements and shall be available as specified options. Options must maintain same construction specifications as standard components. Standard modesty panel and full height modesty panel shall include fully welded integrated horizontal raceway to manage power cord sets, cables, voice and data lines and must permit continuous cable routing through abutting worksurfaces. Fully welded steel horizontal raceway shall provide a cable management area 6"h x 1.7" deep and run the entire perimeter of worksurface modesty panel. Worksurface shall include Power Rings- wire retention devices constructed of nylon or equivalent non-conductive material to organize and retain cable and wires. Wire retention device must permit separation of data/voice transmissions from utility power cables. Modesty panel or raceway must accept multiple wire retention devices to prevent cables and wiresfrom falling out of raceway area., 1, EA;
LI 002, G-57-2 DESCRIPTION: Organizers Qty 1 36H X 48W Organizer Closed Compartment, 36"H with shelf on top with 20" clearance Qty 1 36H X 36W Organizer with shelf, 20" clearanceQty 1 36H X 30W Organizer with shelf, 20" clearanceQty 1 36H X 54W Closed Compartment, 36"H with shelf on top with 20" clearance Qty 2 36H X48X48 Corner Organizer with curved shelf, 20" clearance CHARACTERISTICS Overheads shall be self-supporting (not panel-hung) and capable of being readily relocated The overhead support structure shall be mechanically attached to the worksurface with no exposed worksurface. Overhead units shall consist of two (2) vertical uprights and modular rear panel's) to create aself-supporting structure for privacy and workstation storage. Uprights shall be of 16 and 20 gauge steel construction with .82" front radius. Overhead design shall permit use with other manufacturer's laminate tops (1" minimum top thickness The finish of the overhead system shall match the finish of all other workstation components. Overhead compartments shelf depth shall be at least 13.5" deep to accommodate 3-ring binders. Flipper doors shall be operational from a seated position Flipper doors and shelf units shall be of metal construction with radiused edges. Privacy panel shall be constructed of steel and include a fabric covered, tackable surface consisting ofa single piece of fabric and attached securely and continuously along the entire perimeter of the panel with no visible puckering or flaws. Privacy panel shall be provided as required in height of 20". Flipper door shall be available with textured steel front or fabric covered with a variety of fabric choices., 1, EA;
LI 003, G-57-2 DESCRIPTION Task Lighting CHARACTERISTICS 24" Task Light For 30" + Task lights shall be standard components of the manufacturer's modular furniture products. Task lights shall have a finish to match other workstation components Task lights shall have a structurally sound mounting device which will prevent accidental removal but which can be easily removed and relocated, All fixture diffusers, grilles, or other covering shall be easily removable to permit cleaning and replacing. Includes T8 lamp (1" diameter). Fixture diffuser shall be of prismatic design. Each fixture shall include a nine foot factory installed electrical cord set with a grounded plug. Cord set must match finish of fixture., 4, EA;
LI 004, G-57-2 DESCRIPTION Mobile Pedestals CHARACTERISTICS Box/Box/File Mobile Pedestal Pedestals shall be available mobile Pedestals shall be tested in accordance with the requirements of ANSI/BIFMA X5.3- 1989 All file drawers shall have full extension ball-bearing suspensions or slides. All drawers shall operate smoothly but shall not open accidentally. Drawer front shall include a full width pull handle. Pedestal body shall of metal construction with seamless shell. Mobile pedestal shall include two (2) locking and two (2) non-locking casters that can be easily installed without tools. Drawers shall be of metal construction with a textured or smooth finish. Mobile pedestals must befurnished with internal counterbalance weights to prevent instability and tipping. Box drawer requirements include one (1) pencil or convenience tray and minimum of two (2) dividers. All file drawers shall come with hardware to accommodate legal or letter size hanging file folders., 2, EA;
LI 005, G-57-2 DESCRIPTION Power 15 Amp Under-Surface Mounted Power Strip W/ Surge ProtectorCHARACTERISTICS -Circuit breaker for overload protection Mounting Hardware 15' power cord -420 Joule rating 400 V clamping -40db rating Less than 5 nano sec. response time Circuit breaker for overload protection, 2, EA;
LI 006, G-57-2-01 DESCRIPTION Free Standing Horseshoe shape work area with Peninsula:8'6" x 13'6" x 8' Modular Desks: Qty 2 48 X 30 X 29 Left upright should be a full upright with a 30" foot/Right upright should be transitional with a 24" footQty 1 42 X 30 X 29 Left and right upright should be transitional 24" footQty 2 48 X 48 X 30 X 30 Curved Corner/ Left and right upright should be transitional 24" foot CHARACTERISTICS Worksurface shall consist of complete steel base unit and high pressure laminate top. Worksurface shall be available as a self-supporting unit (freestanding) which includes two (2) uprights (legs) with tubular feet and a 12", 26 or 32 modesty panel (back panel). Uprights shall be constructed of 16 and 20 gauge steel with fully radiused leading edge. Modesty panel shall be constructed of 20 gauge steel and includes cable access ports which correspond to cable access ports located in the desktop laminate. Partial modesty panel shall be available to provide minimum clearance of 16" (applicable to 29" high worksurface) to allow for ventilation, base plate or raceway accommodation. Corner Worksurfaces and transition connectors shall be available as freestanding units. A full depth leg design and full height modesty panel design shall be available to address privacy and aesthetic requirements and shall be available as specified options. Options must maintain same construction specifications as standard components. Standard modesty panel and full height modesty panel shall include fully welded integrated horizontal raceway to manage power cord sets, cables, voice and data lines and must permit continuous cable routing through abutting worksurfaces,. Fully welded steel horizontal raceway shall provide a cable management area 6"h x 1.7" deep and run the entire perimeter of worksurface modesty panel. Worksurface shall include Power Rings- wire retention devices constructed of nylon or equivalent non-conductive material to organize and retain cable and wires. Wire retention device must permit separation of data/voice transmissions from utility power cables. Modesty panel or raceway must accept multiple wire retention devices to prevent cables and wires from falling out of raceway area., 1, EA;
LI 007, G-57-2-01 DESCRIPTION Organizers Qty 2 36H X 48W Organizer Closed Compartment, 36"H with shelf on top with 20" clearance Qty 1 36H X 42W Organizer with shelf, 20" clearanceQty 2 36H X48X48 Corner Organizer with curved shelf, 20" clearance CHARACTERISTICS Overheads shall be self-supporting (not panel-hung) and capable of being readily relocated The overhead support structure shall be mechanically attached to the worksurface with no exposedworksurface. Overhead units shall consist of two (2) vertical uprights and modular rear panel's) to create aself-supporting structure for privacy and workstation storage. Uprights shall be of 16 and 20 gauge steel construction with .82" front radius. Overhead design shall permit use with other manufacturer's laminate tops (1" minimum top thickness The finish of the overhead system shall match the finish of all other workstation components. Overhead compartments shelf depth shall be at least 13.5" deep to accommodate 3-ring binders. Flipper doors shall be operational from a seated position Flipper doors and shelf units shall be of metal construction with radiused edges. Privacy panel shall be constructed of steel and include a fabric covered, tackable surface consisting ofa single piece of fabric and attached securely and continuously along the entire perimeter of the panel with no visible puckering or flaws. Privacy panel shall be provided as required in height of 20". Flipper door shall be available with textured steel front or fabric covered with a variety of fabric choices., 1, EA;
LI 008, G-57-2-01 DESCRIPTION Task Lighting 24" Task Light For 30" + CHARACTERISTICS Task lights shall be standard components of the manufacturer's modular furniture products. Task lights shall have a finish to match other workstation components Task lights shall have a structurally sound mounting device which will prevent accidental removal butwhich can be easily removed and relocated, All fixture diffusers, grilles, or other covering shall be easily removable to permit cleaning and replacing. Includes T8 lamp (1" diameter). Fixture diffuser shall be of prismatic design.Each fixture shall include a nine foot factory installed electrical cord set with a grounded plug. Cord set must match finish of fixture., 3, EA;
LI 009, G-57-2-01 DESCRIPTION Mobile PedestalsCHARACTERISTICS Box/Box/File Mobile Pedestal Pedestals shall be available mobile Pedestals shall be tested in accordance with the requirements of ANSI/BIFMA X5.3- All file drawers shall have full extension ball-bearing suspensions or slides. All drawers shall operate smoothly but shall not open accidentally. Drawer front shall include a full width pull handle. Pedestal body shall of metal construction with seamless shell. Mobile pedestal shall include two (2) locking and two (2) non-locking casters that can be easily installed without tools. Drawers shall be of metal construction with a textured or smooth finish. Mobile pedestals must be furnished with internal counterbalance weights to prevent instability and tipping. Box drawer requirements include one (1) pencil or convenience tray and minimum of two (2) dividers. All file drawers shall come with hardware to accommodate legal or letter size hanging file folders., 2, EA;
LI 010, G-57-2-01 DESCRIPTION Power 15 Amp Under-Surface Mounted Power Strip W/ Surge ProtectorCHARACTERISTICS -Circuit breaker for overload protection Mounting Hardware 15' power cord -420 Joule rating 400 V clamping -40db rating Less than 5 nano sec. response time Circuit breaker for overload protection, 2, EA;
LI 011, G-57-A DESCRIPTION Free Standing Work area Modular Desks Qty 1 72 X 30 X 29 Left upright should be a full upright with a 30" foot/Right upright should be transitional with a 24" foot including full modesty panel 1 42 X 30 X 29 Left upright should be transitional 24" foot /Right 19" foot Worksurface shall consist of complete steel base unit and high pressure laminate top. Worksurface shall be available as a self-supporting unit (freestanding) which includes two (2) uprights (legs) with tubular feet and a 12", 26 or 32 modesty panel (back panel). Uprights shall be constructed of 16 and 20 gauge steel with fully radiused leading edge. Modesty panel shall be constructed of 20 gauge steel and includes cable access ports which correspond to cable access ports located in the desktop laminate. Partial modesty panel shall be available to provide minimum clearance of 16" (applicable to 29" high worksurface) to allow for ventilation, base plate or raceway accommodation. Corner Worksurfaces and transition connectors shall be available as freestanding units. A full depth leg design and full height modesty panel design shall be available to address privacy and aesthetic requirements and shall be available as specified options. Options must maintain same construction specifications as standard components. Standard modesty panel and full height modesty panel shall include fully welded integrated horizontal raceway to manage power cord sets, cables, voice and data lines and must permit continuous cable routingthrough abutting worksurfaces,. Fully welded steel horizontal raceway shall provide a cable management area 6"h x 1.7" deep and run the entire perimeter of worksurface modesty panel. Worksurface shall include Power Rings- wire retention devices constructed of nylon or equivalent non-conductive material to organize and retain cable and wires. Wire retention device must permit separation of data/voice transmissions from utility power cables. Modesty panel or raceway must accept multiple wire retention devices to prevent cables and wiresfrom falling out of raceway area., 1, EA;
LI 012, G-57-A DESCRIPTION Organizers CHARACTERISTICS 36H X 42W Organizer closed compartment and upper shelf 20" clearance Overheads shall be self-supporting (not panel-hung) and capable of being readily relocated The overhead support structure shall be mechanically attached to the worksurface with no exposedworksurface. Overhead units shall consist of two (2) vertical uprights and modular rear panel's) to create aself-supporting structure for privacy and workstation storage. Uprights shall be of 16 and 20 gauge steel construction with .82" front radius. Overhead design shall permit use with other manufacturer's laminate tops (1" minimum top thickness The finish of the overhead system shall match the finish of all other workstation components. Overhead compartments shelf depth shall be at least 13.5" deep to accommodate 3-ring binders. Flipper doors shall be operational from a seated position Flipper doors and shelf units shall be of metal construction with radiused edges. Privacy panel shall be constructed of steel and include a fabric covered, tackable surface consisting ofa single piece of fabric and attached securely and continuously along the entire perimeter of the panel with no visible puckering or flaws. Privacy panel shall be provided as required in height of 20". Flipper door shall be available with textured steel front or fabric covered with a variety of fabric choices., 1, EA;
LI 013, G-57-A DESCRIPTION Task Lighting CHARACTERISTICS 24" Task Light For 30" + Task lights shall be standard components of the manufacturer's modular furniture products. Task lights shall have a finish to match other workstation components Task lights shall have a structurally sound mounting device which will prevent accidental removal butwhich can be easily removed and relocated, All fixture diffusers, grilles, or other covering shall be easily removable to permit cleaning and replacing. Includes T8 lamp (1" diameter). Fixture diffuser shall be of prismatic design. Each fixture shall include a nine foot factory installed electrical cord set with a grounded plug. Cord set must match finish of fixture., 1, EA;
LI 014, G-57-A DESCRIPTION Mobile Pedestals CHARACTERISTICS Box/Box/File Mobile Pedestal Pedestals shall be available mobile Pedestals shall be tested in accordance with the requirements of ANSI/BIFMA X5.3- 1989 All file drawers shall have full extension ball-bearing suspensions or slides. All drawers shall operate smoothly but shall not open accidentally. Drawer front shall include a full width pull handle. Pedestal body shall of metal construction with seamless shell. Mobile pedestal shall include two (2) locking and two (2) non-locking casters that can be easily installed without tools. Drawers shall be of metal construction with a textured or smooth finish. Mobile pedestals must befurnished with internal counterbalance weights to prevent instability and tipping. Box drawer requirements include one (1) pencil or convenience tray and minimum of two (2) dividers. All file drawers shall come with hardware to accommodate legal or letter size hanging file folders., 1, EA;
LI 015, G-57-A DESCRIPTION Power 15 Amp Under-Surface Mounted Power Strip W/ Surge ProtectorCHARACTERISTICS -Circuit breaker for overload protection Mounting Hardware 15' power cord -420 Joule rating 400 V clamping -40db rating Less than 5 nano sec. response time Circuit breaker for overload protection, 1, EA;
LI 016, J-57-7 DESCRIPTION Free Standing Work area --- Modular Desks Qty 4 36 X 24 X 29 Left upright should be a full upright with a 24" foot/Right upright should be transitional with a 19" foot including full modesty panelQty 2 30 X 24 X 29 Left and right upright 19"footQty 3 36 X 36 X 24 X 24 Curved Corner, Left upright should be transitional 19" foot /Right 19" footCHARACTERISTICS Worksurface shall consist of complete steel base unit and high pressure laminate top. Worksurface shall be available as a self-supporting unit (freestanding) which includes two (2) uprights (legs) with tubular feet and a 12", 26 or 32 modesty panel (back panel). Uprights shall be constructed of 16 and 20 gauge steel with fully radiused leading edge. Modesty panel shall be constructed of 20 gauge steel and includes cable access ports which correspond to cable access ports located in the desktop laminate. Partial modesty panel shall be available to provide minimum clearance of 16" (applicable to 29" high worksurface) to allow for ventilation, base plate or raceway accommodation. Corner Worksurfaces and transition connectors shall be available as freestanding units. A full depth leg design and full height modesty panel design shall be available to address privacy and aesthetic requirements and shall be available as specified options. Options must maintain same construction specifications as standard components. Standard modesty panel and full height modesty panel shall include fully welded integrated horizontal raceway to manage power cord sets, cables, voice and data lines and must permit continuous cable routingthrough abutting worksurfaces,. Fully welded steel horizontal raceway shall provide a cable management area 6"h x 1.7" deep and run the entire perimeter of worksurface modesty panel. Worksurface shall include Power Rings- wire retention devices constructed of nylon or equivalentnon-conductive material to organize and retain cable and wires. Wire retention device must permit separation of data/voice transmissions from utility power cables. Modesty panel or raceway must accept multiple wire retention devices to prevent cables and wiresfrom falling out of raceway area., 1, EA;
LI 017, J-57-7 DESCRIPTION Organizers Qty 1 16H X 72W Organizer with Reception surface Qty 1 36H X 36W Organizer closed compartment and upper shelf 20" clearance Qty 1 36H X 72W Organizer closed compartment and upper shelf 20" clearance CHARACTERISTICS Overheads shall be self-supporting (not panel-hung) and capable of being readily relocated The overhead support structure shall be mechanically attached to the worksurface with no exposed worksurface. Overhead units shall consist of two (2) vertical uprights and modular rear panel's) to create a self-supporting structure for privacy and workstation storage. Uprights shall be of 16 and 20 gauge steel construction with .82" front radius. Overhead design shall permit use with other manufacturer's laminate tops (1" minimum top thickness The finish of the overhead system shall match the finish of all other workstation components. Overhead compartments shelf depth shall be at least 13.5" deep to accommodate 3-ring binders. Flipper doors shall be operational from a seated position Flipper doors and shelf units shall be of metal construction with radiused edges. Privacy panel shall be constructed of steel and include a fabric covered, tackable surface consisting ofa single piece of fabric and attached securely and continuously along the entire perimeter of the panel with no visible puckering or flaws. Privacy panel shall be provided as required in height of 20". Flipper door shall be available with textured steel front or fabric covered with a variety of fabric choices., 1, EA;
LI 018, J-57-7 DESCRIPTION Task Lighting Qty 1 24" Task Light Qty 1 48" Task Light CHARACTERISTICS Task lights shall be standard components of the manufacturer's modular furniture -- Please refer to FedBid for complete list of contract requirement(s) and terms and conditions.