| 65--MEDICAL WASTE STERILIZER |
| Program Summary |
 |
| Title: |
65--MEDICAL WASTE STERILIZER |
| GovCB Opps ID : |
ADP12043905610001013 |
| Document Type: |
Modification to a Previous Notice |
| FSC Code: |
65 - Medical, Dental, and Veterinary Equipment and Supplies
|
| NAICS Code: |
332420 - Metal Tank (Heavy Gauge) Manufacturing |
| Set Aside: |
N/A |
| Solicitation No.: |
VA-244-08-RP-0145 |
| Source: |
http://www1.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/VA%2D244%2D08%2DRP%2D0145/Modification%20... |
Place of Performance: |
Address: VA PITTSBURGH HEALTHCARE SYSTEM;UNIVERSITY DRIVE C;PITTSBURGH, PA Postal Code: 15240 Country: USA
|
Posted Date: |
Feb 29, 2008 |
| Last Update: |
Feb 29, 2008 |
| Due Date: |
Mar 17, 2008 |
|
| Description |
 |
General Information
| Document Type: |
Modification to a Previous Notice |
| Solicitation Number: |
VA-244-08-RP-0145 |
| Posted Date: |
Feb 29, 2008 |
| Original Response Date: |
Mar 17, 2008 |
| Current Response Date: |
Mar 17, 2008 |
| Original Archive Date: |
May 16, 2008 |
| Current Archive Date: |
May 16, 2008 |
| Classification Code: |
65 -- Medical, dental & veterinary equipment & supplies |
| Set Aside: |
N/A |
| Naics Code: |
332420 -- Metal Tank (Heavy Gauge) Manufacturing |
Contracting Office Address
Department of Veterans Affairs;Contracting Office (90C-H);VA Pittsburgh Healthcare System;7180 Highland Drive;Pittsburgh PA 15206
Description
SOLICITATION VA-244-08-RP-0145 IS CANCELLED IN ITS ENTIRETY. The VA Pittsburgh Healthcare System, University Drive C, Pittsburgh, PA    15240 has a requirement for a Medical Waste Autoclave.    NAICS code is 332420. The scope of the project bid shall include:              Site Preparation, Equipment, Installation, Validation Testing, Operator Training, and                Maintenance. Site Preparation shall include:              Dismantling and removal of existing autoclave equipment, and Erect Steel Platform.              Dismantling and removal of    existing platform and compactor at dock height.                        Erect steel Platform at dock height              Platform shall be of sufficient capacity and area for Equipment Placement, Equipment                Operation, Equipment Service and Sufficient walkway access from paved lot to              storage area and dock.    Platform shall include: Stair access to/from paved lot and              Stair access to/from storage area. Erect suitable enclosure for equipment on new steel              platform including cover. Adaptation and extension of existing utility services to suite                new equipment.              Shall Include:    Steam, Electricity, Compressed Air, Water, Vent, Drain                Equipment (Shall not have a shredder) but should consist of:    One new medical                waste autoclave having the following Physical characteristics:    Dimensions:              horizontal cylinder approx 5' in Diameter by 14' long, Vessel and piping of Stainless                Steel, Fully insulated vessel & Piping, Vessel must have ASME Stamp U, Controls              must have UL Label, Platform scale, Radiation    Monitor & Detector, Liquid Ring              Vacuum Pump, Bin washing system.    Material Handling Characteristics:    Five (5)              Carts/Bins shall be provided. Cart/Bin shall be constructed of aluminum and/or              stainless steel have a minimum capacity of    1.25 cu yds. each.      It should be self-              dumping into the mouth of the compactor from    dock height (without the use of                mechanical dumper/tipper), include a removable and    securable lid, be marked with              the Biohazard symbol and the word Biohazard and be sure that the two will fit into              the vessel for processing during each cycle and also be separable from one another              such that the floor castors are never subjected to the autoclave process.              The Control Characteristics: PLC process controller, UPS power              supply and surge protection and User Interface Including    Minimum 17" color touch              screen, Operator Identification and authorization , Status/Instruction notification, real              time process temperature indicator, real time process pressure indicator, Door                Position and Seal Status indicator,    and Spore Testing reminder/ notification.    Must be              Network ready with Built-in Records Management Characteristics, Integrated              Electronic Searchable Database of equipment records, Records retention on board for              a period of 7 years, including cycle history, alarm/event history, operator training and                maintenance, and spore testing.    Integrated Laser Printer shall be provided and Laser              Printer shall use 8.5" x 11" cut sheet paper.    Integrated DVD-R/W shall be provided              for Database back-up, and Web based records access.    Process Characteristics: User            selectable cycle based on waste load characteristics,    Automatic parametric            setting based on weight, Airborne Pathogen treatment by gravity steam (before Pre-            vacuum).    Pre-vacuum cycle(s):    Single or multiple cycles depending on waste              characteristics:    Single pulse for Red Bag Waste, Double pulse for large containers &            Lab Waste, Triple pulse for suction canisters, Cool Down Cycle, cold water spray            against bin sides renders bin safe to touch. Efficacy Characteristics: Shall meet or            exceed efficacy standards set by the State of Pennsylvania, Comprehensive            manufacturers efficacy testing protocols and results shall be provided.    Shall            also include Independent 3rd party verification within the last 3 years, Include loading          descriptions and testing protocols. Suction Canister testing must be included and prove            a minimum 4 log 10 reduction of G. Stearothermophilus.    Red Bag testing must be            included and prove a minimum 4 log 10 reduction of G. Stearothermophilus.          Compactor:    One Compactor including the following: Minimum Self Contained 30          yard unit (Sealed Unit), Gated Feed Hopper, Remote Operator Station, UL Rated Key          Operated with All Circuits Fused - 3 Push Button Station Start/Stop/Reverse, Fire          hose connection - Meets all of ANSI and OSHA standards, Advanced Warning Light          of 3/4 Filled, Thermostatically controlled Oil Heater, Electric Motor 3/60/208-230.          Installation:    Installation of all above equipment shall include transportation of          equipment to site, include placement and fastening of all equipment, include        connection of utilities to equipment as necessary, Steam, Electricity, Compressed Air,        Water, Vent, Drain, and be in accordance with State & Local Codes.    There should be          operational testing of equipment and components, and Calibration of    Scale, Radiation          Monitor, Thermocouple and Pressure Transducer.    Validation Testing shall be          performed to validate the manufacturers recommended cycle protocols and parameters,          and include adjustments to protocols and parameters as necessary to meet standards          and be completed prior to final acceptance of project completion.          Operator Training shall be provided to daily users, maintenance personnel, and          appropriate department supervisors and managers.    Service:    Maintenance Service            Contract on Sterilizer Shall    Include a 10 year service contract including all parts,              labor, freight, transportation and travel expenses, except autoclave cart liner to be          performed by a qualified technician.    Response times:    If the call is received by 10          AM, the response will be the next business day for parts orders and 48 hours for          technician visits.    It shall include Quarterly Preventative maintenance, including          additional and ongoing Operator training as needed.    It shall include preventative          maintenance according to the manufacturer's schedule and    shall include include            routine and emergency repair Service, including all parts, labor, freight, transportation          and travel expenses.    This does not include the Compactor. Pricing for the bid shall be one fixed total price for all of the above.    The solicitation will be made available on or about March 7, 2008 and the date for      receipt of proposals will be March 17, 2008.    Hard copy requests of solicitation must be in writing and submitted to Kathleen Policicchio (90C-H), VA Pittsburgh Healthcare System, 7180 Highland Drive, Pittsburgh, PA    15206    Amendments to the solicitation will be posted at the Fedbizopps Website.    All bidders are advised they are responsible for obtaining amendments to the solicitation from the FBO website. Interested offerors must go to the Fedbizopps website to be entered on the Bidders Mailing List and to obtain copies of the Bidders Mailing List.    All questions must be submitted in writing to the issuing office.    Award is subject to the Availability of Funds.
Point of Contact
Kathleen S Policicchio Contract Specialist 412-365-5438
Email your questions to Contract Specialist at Kathleen.Policicchio@med.va.gov
Place of Performance
| Address: |
VA PITTSBURGH HEALTHCARE SYSTEM;UNIVERSITY DRIVE C;PITTSBURGH, PA |
| Postal Code: |
15240 |
| Country: |
USA |
|
|