Description
The U.S. Department of Agriculture, Gifford Pinchot National Forest in Vancouver, Washington intends to procure one 30kVA Liebert NX Three-Phase Uninterruptible Power Supply and one Three Breaker 125-Amp Maintenance Bypass Panelboard(s), meeting the specifications listed below. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. All proposals must be submitted by May 30, 2007.

The solicitation number for this project is AG-05K3-S-07-0026 and is being issued as a Request For Quotation. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-16.

This combined synopsis/solicitation is issued as a service disabled-veteran / small business set-aside. The applicable NAICS code is 423610 with corresponding size standard of 100 employees.

LINE ITEMS

ITEM 1 = Liebert NX Single Module UPS System, three-phase Uninterruptible Power Supply,
Model No. 38SA030C0CHJA10, Quantity = 1, Unit = Lump Sum

Provide Liebert brand name or equal per FAR Clause 52.211-6 incorporated by reference. The most important characteristic for this product is the Single Line Power Supply (single feed). The design of the computer room and IT room equipment are based on a UPS with only one power supply line.

MINIMUM SPECIFICATIONS

Single input, true on-line, double conversion.

IGBT pulse-width modulated (PWM) rectifier providing 0.99 input power factor and 4% reflected input current distortion (THD).

Temperature compensated separate battery charger to allow use with valve-regulated lead acid (VRLA), wet cell lead acid, and NiCad battery systems.

IGBT pulse-width modulated (PWM) inverter

Automatic continuous duty static transfer switch

Internal maintenance bypass switch

All digital microprocessor based monitoring and ActiveStar? Digital Signal Processing (DSP) control system

Back-lit LCD Graphic Display with multilingual support and user friendly navigation menu

Alarm history database

Redundant cooling fans

Local EPO with provision for Remote EPO

Three (3) Intellislot? Communication Ports

IP 20 enclosure

Casters and leveling feet

Meets ISTA 1B transportation requirements

Meets FCC Part 15, Class A

UL and cUL Listed to UL Standard 1778

Seismic Floor Anchor Kit

1 (One) Intellislot? Relay Contact Interface Kit ? This hot-installable card provides relay contact signals for ?On Battery?, ?Low Battery?, ?On Bypass?, ?UPS Fault?, ?Summary Alarm?. Connections are to be DB25F connector with cable provided by the end user.

1 (One) Intellislot? 10/100 Mbit Ethernet OPENCOMMS WEBCARD ? This hot-installable card is the next generation SNMP card and delivers SNMP and Web management to any Liebert UPS (fitted with the card) connected to an 10 or 100 Mbit Ethernet network and provides for the in-the-field upgrade of SNMP firmware. The kit includes the Intellislot card, MIB, configuration cable and installation manual.

Alarms and parametric data are transmitted over the network using SNMP and a direct connection can be made to the UPS via a web browser.

Internal Battery System rated for 9 minutes at a 30 kVA load with the following features:
- HJ with USP12-140 Internal batteries, to save external floor space
- Internal battery system is fused and provides a disconnecting means for servicing


ITEM 2 - One (1) Three Breaker 125-Amp Maintenance Bypass Panelboard(s), Model MBP3125C00S3851, with the following features: Quantity = 1, Unit = Lump Sum

Wall Mounted panel board
Cooper Main Bus
80% rate standard interrupting
Each breaker is supplied with 2A/2B auxiliary switch(s)
Key Interlock System
Emergency Power Off controls to allow remote trip of the maintenance bypass and isolation breakers
UL 67 listed

DATE AND PLACE OF DELIVERY

30kVA UPS is to be delivered to the Mount St Helens National Volcanic Monument building site located at 42218 NE Yale Bridge Road, Amboy, Washington, 98601 by no later than July 30, 2007.

PAYMENT

Payments under this project will be made in accordance with the applicable clauses and provisions listed below.

APPLICABLE CLAUSES AND PROVISIONS

The following clauses and provisions are incorporated by reference in this combined synopsis/solicitation. All clauses and provisions can be viewed in full text at www.arnet.gov .

52.212-1 Instructions to Offerors-Commercial Items


52.212-2 Evaluation-commercial Items (Offerors submitting a quote will be evaluated based on price, product quality, and proximity of parts/services for backhoe within the local area. One award will be made to the offeror providing the quote that represents the best value to the Government, all factors above taken into consideration. Offerors shall supply with their quotation all pertinent information on the product they are quoting and a list of customers who can be contacted to establish their level of satisfaction with the offerors products. Offerors should include with their quotation and product information the duration and cost of any available extended warranties as well as the location of the nearest service/parts providers. Quotations should also include the cost of delivery to the Mount St Helens National Volcanic Monument site in Amboy, WA, as well as orientation of the product to the operators.)

52.212-3 Offeror Representations and Certifications-Commercial Items (offeror shall complete and submit with quotation)

52.212-4 Contract Terms and conditions-Commercial Items

52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items (clauses 52.219-6, 52.222-3, 52.222-19, 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-3, 52.225-13, 52.232-33)

52.211-6 Brand Name or Equal




Home - Browse By Keyword - Browse By Region - About Us - Sitemap - Help - contact Us - Privacy Policy - Terms of Use
Copyright 2004 GovCB.com All rights reserved