Program Summary
Title: ENVIRONMENTAL CHAMBER
GovCB Opps ID : ADP12089673520001217
Document Type: Combined Synopsis/Solicitation
FSC Code: 66 - Instruments and Laboratory Equipment
Set Aside: Total Small Business
Solicitation No.: 464-08MR-1560
Source: https://www.fbo.gov/?s=opportunity&mode=form&id=56275ab8c3d0eb97c48d6280bc1a397b&tab=cor...
Place of
Performance:

Posted Date:
Apr 22, 2008
Last Update: Apr 29, 2008
Due Date: May 02, 2008

Description
ENVIRONMENTAL CHAMBER
Solicitation Number: 464-08MR-1560
Agency: Department of Labor
Office: Mine Safety and Health Administration
Location: Acquisition Management Branch (WV)
  • Print
  • Link
    Copy or Bookmark this Page

    Copy the url below for a direct link to this page.

    Bookmark this page by right-clicking here and choosing "Bookmark This Link..."

Opportunity History
  • Original Synopsis
    Apr 22, 2008
Solicitation Number:
464-08MR-1560
Notice Type:
Combined Synopsis/Solicitation
Synopsis:
Added: Apr 22, 2008 1:45 pm
MSHA IS SEEKING QUOTES FOR THE FOLLOWING:

QTY. 1 ESX-4CA PLATINOUS TEMPERATURE & HUMIDITY CHAMBER
QTY. 1 DRY AIR PURGE
QTY. 1 WATER FILTER SYSTEM FOR HUMIDITY SUPPLY
QTY. 1 HUMIDITY WATER SUPPLY TANK
QTY. 1 INNER GLASS DOOR WITH FOUR OPERATION PORTS (NO OUTER WINDOW/LIGHT)
QTY. 1 CABLE PORT, 2 DIAMETER WITH TWO FLEXIBLE SILICONE PLUGS

Below are specifications for Environmental Chamber:

1. Temperature Range: -73C to +150C

2. Humidity Range: 10 to 90%

3. Load: The test specimen dimensions vary; the chamber is used for approval testing of gas detectors used in underground mining. The largest system has included components (non-portable) that weigh up to 40lbs; heat output of specimens is not specified, but all external surfaces of tested equipment is routinely carried by, or manipulated by hand (surfaces certainly less than 40C).

4. Heating Rate: Rapid changes in temperature not needed, either up or down. Test procedures allows 1 hour between tests, which are conducted at 5 F intervals. In other words, we allow the samples to soak for 1 hour after the air temperature has stabilized.

5. Cooling Rate: See above

6. Power: 220VAC/60Hz [Single or 3-Phase OK]

7. Interior size: 27 to 32 cubic feet

8. Exterior size: Size limitations: The door to get into the lab is 93 by 84 . The lab height is ~12 feet.

9. Facilities: Water Reservoir for humidity supply (plumbed line available, but reservoir desired)

10. Test standards: Most tests are custom from Title 30 CFR Parts 22 and 27. See http://www.msha.gov/30cfr/22.0.htm and http://www.msha.gov/30cfr/27.0.htm. The standard test procedures can be found at http://www.msha.gov/TECHSUPP/ACC/StandardTestProcs/ASTP2203.pdf, http://www.msha.gov/TECHSUPP/ACC/StandardTestProcs/ASTP2228.pdf, http://www.msha.gov/TECHSUPP/ACC/StandardTestProcs/ASTP2229.pdf. The chamber will be used for custom tests of equipment recovered from mine explosions; low humidity (approximately 10%RH) may rarely be desirable.

11. Controller: Programmable

12. Window: Observation Window (or equivalent)

13. Communication: Serial (RS-232, RS485, USB, etc.) OR parallel (GPIB), OR analog outputs of temperature and humidity

13. # of Access Ports One 2 Port for electrical cords and gas tubing

14. Gloves port: One set (or equivalent)

15. Shelves: One set (see Load above)

16. Interior light: One (if necessary for visibility)

PLEASE PROVIDE QUESTIONS VIA E-MAIL BY 04/28. NO PHONE CALLS WILL BE ACCEPTED.
ITEM NUMBER PROVIDED BY ESPEC NORTH AMERICA. PLEASE QUOTE BRAND NAME OR EQUIVALENT.



Contracting Office Address:
1301 Airport Road
Beaver, West Virginia 25813-9426
Place of Performance:
DEPT. OF LABOR MINE SAFETY & HEALTH ADMINISTRATION RR 1, BOX 251, INDUSTRIAL PARK ROAD
TRIADELPHIA, West Virginia 26059
United States
Primary Point of Contact.:
ALEISHA T MOORE
Phone: 304-256-3215
General Information
Notice Type:
Combined Synopsis/Solicitation
Posted Date:
April 22, 2008
Response Date:
May 02, 2008 4:00 pm Eastern
Archiving Policy:
Automatic, 15 days after response date
Archive Date:
-
Set Aside:
Total Small Business
Classification Code:
66 -- Instruments & laboratory equipment
NAICS Code:
334 -- Computer and Electronic Product Manufacturing/334516 -- Analytical Laboratory Instrument Manufacturing




Home - Browse By Keyword - Browse By Region - About Us - Privacy Policy - Terms of Use - Sitemap - Help
Copyright 2004 GovCB.com All rights reserved
4855 River Green Pkwy, Suite 510, Duluth, GA 30096