|
Opportunity History
|
Solicitation Number:
FA8101--08-T-0053
Notice Type:
Solicitation
Synopsis:
Added: March 31, 2008
L/I 0001: ASSEMBLED FULL FLOOR RECLAIM SYSTEM FOR A BLAST ROOM WITH INSIDE DIMENSIONS OF 8 Ft W X 8 Ft H X 16 Ft L. THE BLAST ROOM IS DESIGNED FOR AN IN-OUT WORK FLOW THROUGH ONE SET OF WORK DOORS 8 Ft W X 8 Ft H. (1 ea.). L/I 0002: WIDE LONGITUDINAL WIPE FRAMES INCLUDING 10 GAUGE MILD STEEL HOPPERS AND SWEEP ASSEMBLIES. (3 ea.) L/I 0003: 24in WIDE CROSS WIPER FRAME INCLUDING 10 GAUGE MILD STEEL HOPPER AND SWEEP ASSEMBLIES. (1 ea.). L/I 0004: 1.0 HP DRIVE ASSEMBLY INCLUDING REDUCER AND C-FACE FLANGE MOUNTED TEFC MOTOR AND REQUIRED NEMA 12/3R/3S MOTOR DISCONNECT. (1 ea.). L/I 0005: 1 ? in FLOOR GRATING RATED AT 500 LBS PER SQ FT. (1 ft.). L/I 0006: Nr 60 CHAIN, SPROCKETS, GUARDS, SEALS, BEARINGS, SPACERS AND RELATED HARDWARE. (1 ea.). L/I 0007: FLOOR SUPPORT STEEL. (1 ea.). L/I 0008: INVERTED ANGLE TRACK SYSTEM RATED TO CARRY 2000 LBS ON 32 in CENTERS. (1 ea.). L/I 0009: 7 in X 21 ? in ELEVATOR ASSY APPROX 14 TALL, INCLUDING CAST DUCTILE IRON BUCKETS, ? in THICK X 5 in WIDE NEOPRENE 1650 Nr BELTING, TOP TAKE-UP, 2 HP MOTOR AND DRIVE, AND EASY ACCESS DOORS. (1 ea.). L/I 0010: 12 in GRAVITY TYPE AIR WASH ABRASIVE SEPARATOR WITH INTEGRAL PERFORATED PLATE ROTARY DRUM ASSY. THIS HIGH EFFICIENCY ASPIRATOR SEPARATOR HAS 5 SEPARATE ADJUSTMENTS TO ALLOW MAXIMUM SEPARATION OF THE CONTAMINANTS FROM THE ABRASIVE MIX. THIS SEPARATOR WILL CLASSIFY FERROUS AND NON-FERROUS DRY ABRASIVES. (1 ea.). L/I 0011: 15' OF BOTH 6 in AND 3 in DIAMETER METAL FLEX TRASH HOSE. (1 ft.) L/I 0012: 7 in TO 6 in AND 4 in Y UNIT USED TO VENTILATE THE AIR-WASH UNIT AND THE ELEVATOR ASSY. (1 ft.). L/I 0013: 18 CU FT FREE STANDING ABRASIVE STORAGE HOPPER WITH REQUIRED SUPPORT STEEL AND ABRASIVE SHUT-OFF GATES TO STOP THE FLOW OF AVRASIVE IF REQUIRED. (1 ea.). L/I 0014: 10 GAUGE ROOM WALL PANELS (1 ea.). L/I 0015: 10 GAUGE ROOM ROOF PANELS (1 ea.). L/I 0016: BAFFLED AIR EXHAUST PLENUM (1 ea.). L/I 0017: BAFFLED AIR INLET PLENUMS (2 ea.). L/I 0018: SET OF STRUCTURAL TUBULAR FRAMED WORK DOORS 8 Ft W X 8 Ft H UTILIZING SWING TYPE DESIGN (1 ea.). L/I 0019: PANIC TYPE OSHA APPROVED MAN ESCAPE DOOR WITH VISION WINDOW AND SHIELD. (1 ea.). L/I 0020: 18 GAUGE PANEL CLAMPING ASSEMBLIES TO SEAL ALL WALL AND ROOF PANELS. (1 ea.). L/I 0021: PANEL SEAL CRIMPING TOOL. (1 ea.). L/I 0022: 2 Ft X 4 Ft T-8/ELECTRONIC BALLAST 4-BULB FLUORESCENT LIGHT ASSEMBLIES INCLUDING HINGED SIDEWALL FIXTURES, ? in THICK POLYCARBONATE LENS, GASKETING HIGH OUTPUT T-8 BULBS, CUTOUTS AND FASTENERS. (1 ea.). L/I 0023: OSHA APPROVED LED EXIT LIGHT ASSY WITH BATTERY BACK-UP EMERGENCY LIGHTS THAT COME ON IF POWER IS LOST. (1 ea.). L/I 0024: CFM DOWNFLO DUST COLLECTOR MODEL NUMBER ADFT 208. THE UNIT INCLUDES ABRASIVE INLET PLENUM, FNA AND MOTOR 7 1.2 HP. THE EFFICIENCY OF THE FILTERS IS 99.999% DIWB TI A OARTUCKE IF A .5 MICRON INCLUDING EXHAUST SILENCER ON THE FAN ASSY. (1 ea.) L/I 0025: BOTH 6 in AND 4 in DIAMETER RUBBER FLEX DUCTING HOSE. (1 ft.) L/I 0026: DUCTWORK TO TIE SYSTEM COMPONENTS TOGETHER, AS LONG AS THE DUST COLLECTOR IS POSITIONED WITHIN 15 Ft OF THE BLAST ROOM. (1 ea.) L/I 0027: PREWIRED AND INTERLOCKED NEMA 12 ELECTRICAL CONTROL PANEL, INCLUDING STARTERS, FUSES PUSH BUTTONS, MAIN LINE DISCONNECT, ETC FOR THE ABOVE PROPOSED GOODS INCLUDING ROOM LIGHTS. THE PANEL INCLUDES A 12 VOLT TRANSFORMER FOR THE BLAST POT AND INDICATOR LIGHTS TO SHOW WHEN ALL THE DOORS ARE CLOSED AND THE BLAST POT HAS POWER. ELECTRICS ARE 480/60/3 4-WIRE. (1 ea.). L/I 0028: 6.5 CU FT BLAST POT ASSY WITH FULL PORT REGULATOR AND ABRASIVE CUT-OFF SWITCH AND USER'S EQUIPMENT, WITH RELATED 12 VOLTS DC ELECTRIC CONTROLS, AND RELATED POT RISER ASSY. (1 ea.). L/I 0029: ENTRY DOOR STEEL RAMP. (1 ea.) L/I 0030: STANDARD SOT ABS BLAST DEERT TAN PAINT WILL BE USED ON ALL GOODS QUOTED. (1 ea.) L/I 0031: TWO SETS OF PARTS BOOKS INCLUDING MAINTENANCE AND OPERATIONAL INSTRUCTIONS. (2 ea.). L/I 0032: ASSEMBLY OF THE BLAST ROOM STRUCTURE TO A STATE WHERE TRANSPORTATION REGULATIONS LIMITS FINAL ASSEMBLY. (1 ea.). L/I 0033: SHAKER DECK SEPARATOR ADDED PRICE TO REPLACE THE AIRWASH SEPARATOR WITH A 40 in DIAMETER SHAKER DECK WITH STAINLESS STEEL SCREEN AND BALL DECKS. THE INTENT OF THIS DESIGN IS TO REMOVE A SPECIFIC MESH SIZE ABRASIVE FROM THE WORKING MIX. (1 ea.)
Solicitation 01
Sensitive/Secure Package:
no
Posted Date:
April 7, 2008
Contracting Office Address:
72 CONS
7858 5th Street Ste 1
Tinker AFB,
Oklahoma
73145-9106
Contracting Office Address:
Department of the Air Force, Air Force Materiel Command, Tinker AFB - 72d Contracting Sq, 72 CONS 7858 5th Street Ste 1, Tinker AFB, OK, 73145-9106, UNITED STATES
Place of Performance:
TINKER AFB, OK
73145
Primary Point of Contact.:
Ragan G Harris
Phone: (405) 739-3363
Secondary Point of Contact:
Gene P. Wahweah
Phone: (405) 739-5397
Point of Contact(s):
Ragan Harris, Contracting Officer, Phone (405) 739-3363, Fax (405)739-7423, Email Ragan.Harris@tinker.af.mil - Gene Wahweah, Contracting Officer, Phone (405) 739-5397, Fax (405) 739-7423, Email gene.wahweah@tinker.af.mil
|
General Information
Notice Type:
Modification/Amendment/Cancel
Original Posted Date:
March 31, 2008
Posted Date:
April 7, 2008
Response Date:
May 01, 2008 5:00 pm
Original Response Date:
May 1, 2008
Archiving Policy:
Automatic, on specified date
Original Archive Date:
September 30, 2008
Archive Date:
September 30, 2008
Original Set Aside:
Total Small Business
Set Aside:
Total Small Business
Classification Code:
99 -- Miscellaneous
NAICS Code:
333 -- Machinery Manufacturing/333999 -- All Other Miscellaneous General Purpose Machinery Manufacturing
|